Installation instructions for the Legrand radiant LC2102 Wireless Master Dimmer, a 600W incandescent/halogen 2-wire dimmer for the radiant wireless system.
Installation instructions for the Legrand radiant LC2102 Wireless Master Dimmer, a 600W incandescent/halogen dimmer for standard 2-wire installations, compatible with the radiant wireless lighting control system.
To prevent severe shock or electrocution, always disconnect power at the service panel before beginning work. When replacing an existing device, label wires before disconnecting the old device.
| Rated Load | 2-Gang Installation | 3-Gang Installation |
|---|---|---|
| 600W | 500W / 500W | 500W / 400W / 500W |
Do not pair different-size wires in the same terminal. If wire gauges differ, use a wire nut to add a 6-inch pigtail of the same gauge as the smaller wire before connecting.
Creating a new group: ensure all potential members' LEDs are solid WHITE. Press and hold each potential group member's On Button for 5 seconds until its LED flashes AMBER. Then press and hold the initiator's On Button for 5 seconds — all LEDs flash GREEN for 2 seconds and turn solid WHITE.
Adding/removing a device: press and hold any existing group device's On Button for 5 seconds — current group members flash AMBER, non-group devices flash GREEN. Press and hold any device's On Button for 5 seconds so its LED flashes AMBER (join) or GREEN (leave), then press and hold the initiator's On Button for 5 seconds to confirm.
| Action | Result |
|---|---|
| Press & Release On Button | Off to last level, or On to Off, at 2-second ramp rate |
| Double Tap On Button | Full On at 1-second ramp rate |
| Hold Off Button 2 sec | From On: goes off at a slow 30-second ramp rate |
| Press/Release Paddle (+) | Off→last level at 2-sec ramp; On: +2% per tap |
| Double Tap Paddle (+) | Off→Full On at 1-sec ramp; On: +4% |
| Hold Paddle (+) | Increases level at 5-second ramp rate |
| Press/Release Paddle (−) | On: −2% per tap |
| Double Tap Paddle (−) | On: −4% |
| Hold Paddle (−) | Decreases level at 5-second ramp rate |
Press and hold the On Button for 20 seconds — status LED goes to solid AMBER.
With all device LEDs solid WHITE, press and hold any dimmer's On Button for 10 seconds and release — the initiator's LED flashes GREEN, with blink count indicating the current custom setting selection. Press and release to cycle through settings; use the dimmer paddle to adjust levels for each. Press and hold the initiator's On Button for >2 seconds to exit, or wait for the 60-second timeout.
It is normal for the dimmer to feel warm during operation. Protect dimmers from dirt and dust. To remove a wall plate, insert a flat screwdriver in the notches on the back of the plate and twist gently.