0

Your Cart is Empty

  • Add description, images, menus and links to your mega menu

  • A column with no settings can be used as a spacer

  • Link to your collections, sales and even external links

  • Add up to five columns

  • Jasco ZW4006 (24770) — Z-Wave Plus In-Wall Smart Motion Switch Manual

    August 31, 2026 6 min read

    Installation manual for the Jasco Z-Wave Plus In-Wall Smart Motion Switch, Model ZW4006 / part 24770.

    Full text manual (for reference)

    Installation manual for the Jasco Z-Wave Plus In-Wall Smart Motion Switch, Model ZW4006 / part 24770 — a certified Z-Wave lighting control switch with built-in motion sensor and three modes of operation (Occupancy, Vacancy, Manual).

    Important — Load Rating

    The fixture controlled by the Z-Wave In-Wall Smart Motion Switch must not exceed 960 watts (incandescent), 1800W (15A resistive), or ½ HP motor. The switch is designed only for use with permanently installed fixtures.

    Getting to Know Your Device

    • Turn ON/OFF manually or remotely via a Z-Wave controller
    • Can be included in multiple groups and scenes
    • May be used in single-pole installation or with up to two Jasco Add-on switches in 3-way or 4-way wiring configurations
    • Compatible with all incandescent and CFL/LED bulbs
    • Interchangeable button switch — white and light almond buttons included in package
    • Uses a standard, decorative-size wallplate for single-gang installations (wallplate not included)
    • Blue LED indicates programming confirmation and switch location in a dark room
    • Z-Wave Certified for simple pairing and integrated home automation
    • Screw terminal installation — requires wiring connections for Line (Hot), Load, Neutral, and Ground. A traveler wire is required for 3-way or 4-way installation.
    • Has 3 modes of operation: Occupancy, Vacancy, and Manual (see Programming Options)

    Component Labels

    • A. Ground (Green/Bare)
    • B. Load (Black)
    • C. Line (Black)
    • D. Traveler (Red/Other)
    • E. Neutral (White)
    • F. Top Button — Press & release to turn the switch on
    • G. Bottom Button — Press & release to turn the switch off
    • H. Configuration Button — Changes the operation mode of the switch
    • I. Motion Sensor
    • J. Blue LED — behind cover
    • K. Air Gap Switch — Pull out to disconnect power; push all the way back in for normal operation

    Single-Switch Wiring Installation

    WARNING — SHOCK HAZARD: Turn OFF the power to the branch circuit for the switch and lighting fixture at the service panel. All wiring connections must be made with the power OFF to avoid personal injury and/or damage to the switch. This device is intended for installation in accordance with the National Electric Code and local regulations in the U.S., or the Canadian Electrical Code and local regulations in Canada. If unsure or uncomfortable performing this installation, consult a qualified electrician.

    1. Shut off power to the circuit at the circuit breaker or fuse box, then verify power is OFF to the switch box.
    2. Remove the wallplate.
    3. Remove the switch mounting screws.
    4. Carefully remove the switch from the switch box. DO NOT disconnect the wires.
    5. There are up to five screw terminals on the switch — GROUND (Green/Bare), LOAD (Black, connects to lighting), LINE/Hot (Black, connects to power), TRAVELER (Red/Other, only for 3-way installations), NEUTRAL (White). Match these terminals to the wires connected to the existing switch.
    6. Disconnect the wires from the existing switch, labeling them according to the previous terminal connections.
    7. For multiple-gang boxes, it may be necessary to break off one or both sides of the scored tabs on the front yoke — this does not affect the switch's electrical rating.
    8. Wiring is rated for copper wire only. Use 14 AWG or larger wire suitable for at least 80°C for Line (Hot), Load, Neutral, Ground, and Traveler connections. Strip insulation 1" (25mm) for screw terminals, or 5/8" (16mm) for enclosure holes. UL specifies a tightening torque of 12 lbf-in (14 kgf-cm).
      1. Connect the green or bare copper ground wire to the GROUND terminal.
      2. Connect the black wire that goes to the fixture to the LOAD terminal.
      3. Connect the black wire from the electrical service panel (Hot) to the LINE terminal.
      4. Connect the white wire to the NEUTRAL terminal (use a jumper wire if needed). Note: the traveler terminal is only used for 3-way/4-way wiring and should remain insulated in a 2-way (one switch, one load) system.
    9. Insert the switch into the switch box, being careful not to pinch or crush wires.
    10. Secure the switch to the box using the supplied screws.
    11. Mount the wallplate.
    12. Reapply power at the fuse box or circuit breaker and test the system.

    For 3-way installations, refer to the Jasco Add-on Switch manual — a Jasco Add-on switch is required for multi-switch (3-way or 4-way) installations. Connecting the traveler terminal of this switch to a standard, non-Jasco switch will cause damage or improper function. Do not connect the traveler wire or apply power until Jasco Add-on switches are correctly installed.

    Basic Operation

    Occupancy mode (default): the light turns on automatically when motion is detected and off when motion is no longer detected. Can also be controlled remotely with a Z-Wave controller.

    Vacancy mode: the light turns on by pressing the top button and off automatically when motion is no longer detected. Also controllable remotely.

    Manual mode: the light only turns on/off manually from the front panel, or remotely with a Z-Wave controller.

    Programming Options

    Many controllers offer programming changes through their application. Changes can also be made directly at the switch through button presses. Programming capabilities vary by program and connected device.

    Mode Lights ON When: Lights OFF When:
    Occupancy (default) Automatically Automatically
    Vacancy Press & release top button Automatically
    Manual Press & release top button Press & release bottom button

    To set the mode: press and hold the button until the LED flashes the correct number of times (guide is controller-displayed; see Section 4 diagram in the original manual). Time-out duration does not apply in manual mode.

    Time-out duration (time the light stays on after motion stops): 5 sec, 1 min, 5 min (default), 15 min, 30 min. Set by pressing and holding the button until the LED cycles the correct number of flashes.

    Light sensing (motion sensor only turns light on if the room is dark; does not apply in vacancy or manual modes): On (default) or Off.

    Motion sensitivity (amount of motion required to turn on the light): High, Medium (default), or Low.

    Adding Your Device to a Z-Wave Network

    1. Follow the instructions for your Z-Wave certified controller to include the smart switch in the Z-Wave network.
    2. Once the controller is ready to include your smart switch, press and release the top or bottom button on the switch to include it.

    To Exclude/Reset the Device

    1. Follow the instructions for your Z-Wave certified controller to exclude a device from the network.
    2. Once the controller is ready to exclude your device, press and release the top or bottom button to exclude it.

    To Return to Factory Defaults

    Press and release the top button ten times. Note: only use this if your network's primary controller is missing or otherwise inoperable.

    Changing Button Color

    1. Pinch both tabs down to release the button.
    2. Lift the button up and off.
    3. Put the new button onto the switch, inserting the tabs near the motion sensor first, then the tabs on the opposite side.
    4. Repeat for the button on the other side.

    Z-Wave Interoperability

    This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers/applications. All non-battery-operated nodes act as repeaters regardless of vendor. This device supports the Association Command Class (3 Groups): Group 1 supports Lifeline / Binary Switch Report; Group 2 supports Basic Set, controlled by the local load; Group 3 supports Basic Set, controlled by pressing the On or Off button. Each Association Group supports 5 total nodes.

    Safety Warning — Appliance Control

    WARNING: Exercise extreme caution when using Z-Wave devices to control appliances — operation may occur in a different room than the controlled appliance, and unintentional activation may occur if the wrong remote button is pressed, or due to timed event programming. For these reasons, do not use Z-Wave devices to control electric heaters or other appliances that may present a hazardous condition due to unattended or unintentional/automatic power-on. Z-Wave devices should never be used to supply power to or control the on/off status of medical or life support equipment.

    Specifications

    Power 120 VAC, 60 Hz
    Signal (Frequency) 908.4/916 MHz
    Maximum Loads 960W incandescent, ½ HP motor, or 1800W (15A) resistive
    Range Up to 150 feet line of sight between the wireless controller or nearest Z-Wave receiver module
    Operating Temperature Range 32-104°F (0-40°C)
    Use Indoor use only

    Manufacturer