  • Inovonics EN1722 & EN1723 — Temperature/Humidity Transmitter Datasheet

    September 08, 2026 2 min read

    Specifications for the Inovonics EN1722 external temperature/humidity transmitter (with ACC710 sensor) and the EN1723 dual input temperature transmitter, for use on the EchoStream Commercial Mesh Network.

    Full text manual (for reference)

    Overview

    This datasheet covers two Inovonics EchoStream wireless temperature/humidity transmitters designed for the Inovonics Commercial Mesh Network:

    • EN1722 — external temperature/humidity transmitter, used together with the remote ACC710 sensor. Designed for harsh environments where condensation, frost, or temperature/humidity fluctuations are a concern. The EN1722 requires the ACC710 sensor to operate.
    • EN1723 — dual input temperature transmitter with both an internal onboard sensor (for monitoring ambient indoor temperature) and a user-selectable external thermistor input to match the application.

    Why Inovonics EchoStream Wireless

    • Reliability — the EchoStream 900MHz radio uses frequency hopping, spread spectrum technology to operate reliably even in cluttered wireless environments.
    • Flexibility — the self-configuring Commercial Mesh Network adapts to changing floor plans; new sensors can be added to the network as fast as they can be mounted.
    • Scalability — an intelligent repeater backbone can extend coverage to thousands of sensors across entire commercial campuses.

    EN1722 Transmitter & ACC710 Sensor Specifications

    Parameter Spec
    Temperature Range -4° to 140°F, Fahrenheit or Celsius units
    Temperature Resolution / Accuracy Typical resolution 0.018°F; typical accuracy ±0.5°F at 77°F
    Humidity Range 0–100% RH
    Humidity Resolution / Accuracy 0.03% RH resolution; typical accuracy ±2.0% RH from 10–90% RH
    Transmitter Configuration Measurement intervals of 0.5, 1, 5, or 30 seconds, or 1, 5, 15 minutes; transmission intervals of 10/30 seconds or 1, 2, 5, 10, 15, 30 minutes; Delta T threshold of 0.5, 1, 5, or 10 degrees/%RH (can be disabled)
    Battery 3.0V lithium, 1.4Ah (BAT604); typical 8 year life at 5-minute transmit interval
    Transmitter Dimensions 3.5 x 1.7 x 0.9"
    Transmitter Operating Environment -4° to 140°F, up to 90% humidity non-condensing
    ACC710 Sensor Dimensions 1.7 x 0.5 x 0.3", 60" cable length
    ACC710 Sensor Operating Environment -4° to 140°F, water resistant
    System Requirement Requires the EN4000 serial receiver and an application supporting advanced functionality

    EN1723 Dual Input Temperature Transmitter Specifications

    Parameter Spec
    Internal Measurement Range -13° to 140°F; typical accuracy 0.8°F at room temperature; Fahrenheit or Celsius
    External Measurement Transmitted as temperature or resistance; external thermistor temp range -22° to 212°F; external thermistor resistance range 100 to 250,000 ohms
    External Resistance Accuracy ±1% from 100–500 ohms, ±0.5% from 500 to 250K ohms
    Configuration Options Same measurement/transmission intervals and Delta T options as EN1722
    Battery 3.0V lithium, 1.4Ah (BAT604); typical 8 year life at 5-minute transmit interval
    Physical Characteristics 3.5 x 1.7 x 0.9"
    Operating Environment -4° to 140°F
    System Requirement Requires the EN4000 serial receiver and an application supporting advanced functionality

    Compliance

    RoHS compliant. Product performance depends on the structure and environment in which it operates; specifications subject to change without notice.

    Inovonics, 315 CTC Boulevard, Louisville, CO 80027 — Phone: 303.939.9336 — Toll-Free: 800.782.2709 — sales@inovonics.com — www.inovonics.com