  • Foard Systems FGI Quad Input / Quad Output Devices — Spec Sheet

    September 08, 2026 1 min read

    Spec sheet for the Foard Systems FGI Quad Input / Quad Output devices for switch monitoring and relay/LED/solenoid driving.

    Full text manual (for reference)

    The FGI Quad Input / Quad Output devices provide four switch inputs each with level and transition detection, plus four non-isolated output drivers configured to drive LEDs, external relays or solenoids, or digital signal inputs on another device.

    Overview

    An auxiliary power input is provided, so higher-power output devices can be controlled without significantly affecting FGI control network power usage, and so higher-voltage loads can be controlled. The output drivers on the relay and solenoid driver board are rated to drive up to 24 volts and 1 amp.

    Available Models

    Model Description
    FG-032020-06-330 FGI Quad Input / Quad LED Drive Output, 330 Ohms
    FG-032020-00 FGI Quad Input / Quad Relay and Solenoid Driver Output
    FG-032020-01 FGI Quad Input / Quad Dual Latching Relay Driver Output
    FG-032020- FGI Quad Input / Quad Digital Output

    Specifications

    Category Detail
    Inputs Screw terminal FGI DI port; switch level with transition-detect inputs; auxiliary power input for controlled devices
    Outputs Two screw terminal FGI DO ports; screw terminal power outputs
    Dimensions 2-5/8" x 1-7/8" x 3/4"
    Power Consumption 2.7 mA typical, excluding power used by controlled devices

    Foard Systems Design, Inc. · 1906 Hwy 54 E Suite 200-E, Durham, NC 27713 · (919) 544-2979