  • ELK 319 Series Sensor Setting Guide for the E27 Alarm Engine

    August 31, 2026 4 min read

    ELK 319 Series wireless sensor setting and enrollment guide for the ELK E27 Alarm Engine — covers door/window, PIR, glass break, water, heat, and panic sensors.

    Full text manual (for reference)

    ELK 319 Series wireless sensor setting and enrollment guide for the ELK E27 Alarm Engine. Transmitters can be enrolled via the ElkConnect app using Learn Mode, or by manually entering the TXID. Advanced settings (Opt1, Opt2, Loop #) for each sensor model are detailed below.

    ELK-319DWM — Mini Door/Window

    Enroll: Remove cover, pull out battery isolation tabs to apply power. Press and release the tamper plunger to send enrollment to the panel.

    Advanced Settings: Opt1 (External Contact) = OFF; Opt2 (Open/Closed Swap) = OFF; Loop # = 2

    ELK-319DG — All Weather Door & Gate

    Enroll: Remove cover, pull out battery isolation tabs to apply power. Press and release the tamper plunger.

    Configuration Opt1 Opt2 Loop #
    Built-in reed switch OFF OFF 2
    External N.O. switch ON ON 1
    External N.C. switch ON OFF 1

    Note: Two screw terminals allow an external switch in place of the built-in reed. The reed and external switch are NOT designed to be used simultaneously.

    ELK-319DR — Recessed Door

    Enroll: Remove cover, pull out battery isolation tab. Place a magnet to the sensor and remove it to send enrollment.

    Advanced Settings: Opt1 = OFF; Opt2 = OFF; Loop # = 2

    Note: To change the battery, remove the end cap by twisting 1/8" CCW using a coin or screwdriver, then gently grasp the board's edge with needle-nose pliers and pull out.

    ELK-319WS — Window Reed & Shock Combo

    Enrolling the Built-In Reed: Remove cover; start the panel enroll process; hold a finger on the tamper plunger while removing battery isolation tabs (or inserting batteries) to apply power — keep your finger on the tamper. The panel enrolls the reed and displays the printed TXID # +1 digit higher.

    Enrolling the Shock: Remove battery isolation tabs to apply power; start the panel enroll process; remove the cover or press/release the tamper switch. The panel enrolls the shock at the printed TXID #.

    Advanced Settings (applies to both reed and shock): Opt1 = OFF; Opt2 = OFF; Loop # = 2

    Note: The reed and shock each require 2 separate panel zones. The printed TXID # is for the shock; the reed uses the same TXID with the last digit +1.

    ELK-319PIRC — Ceiling Mount 360° PIR Sensor

    Enroll: Pull out battery isolation tabs to apply power and send enrollment. If already powered, push and release the tamper.

    Advanced Settings: Opt1 = OFF; Opt2 = OFF; Loop # = 1

    Note: Has a 3-minute sleep-mode lockout between motion detections to conserve battery. For walk testing, momentarily remove the sensor from its base to bypass the lockout. Walk test ends after 1 minute of no motion.

    ELK-319PIRW — Wall Mount PIR Sensor

    Same enroll process, advanced settings, and walk-test behavior as the ELK-319PIRC above.

    ELK-319GB — Glass Break Detector

    Enroll: Pull out battery isolation tabs to apply power and send enrollment. If already powered, push and release the tamper.

    Advanced Settings: Opt1 = OFF; Opt2 = OFF; Loop # = 1

    Note: A 5-minute test mode activates when batteries are first installed — test microphone detection range by clapping or jingling keys. Restart test mode anytime by removing/reinstalling batteries. Full alarm testing requires an acoustic glass-break tester.

    ELK-319WA — Water Sensor

    Enroll: Pull out battery isolation tabs to apply power and send enrollment. If already powered, push and release the tamper.

    Advanced Settings: Opt1 = OFF; Opt2 = OFF; Loop # = 2

    Note: To test, form a water bridge between the two metallic contact points with a moistened finger or cloth. A properly working sensor triggers an alarm within ~3 seconds.

    ELK-319HRR — Heat Rate of Rise Detector

    Enroll: Pull out battery isolation tabs to apply power and send enrollment. If already powered, push and release the tamper.

    Advanced Settings: Opt1 = OFF; Opt2 = OFF; Loop # = 1

    Note: To run a manual test, hold a magnet next to the mark on the front edge for ~15 seconds.

    ELK-319PB1 — Heavy Duty 1-Button Panic

    Enroll: Pull out battery isolation tabs to apply power and send enrollment. If already powered, press and hold the button.

    Advanced Settings: Opt1 = OFF; Opt2 = OFF; Loop # = 1

    Note: Program the zone definition to the desired alarm type (Panic or Medical).

    ELK-319KF1 — Single Button Panic

    Same enrollment (press and hold the button if already powered) and settings as the ELK-319PB1 above (Panic or Medical alarm type).

    ELK-319KF4 — Four Button Keyfob

    Enroll: Pull out battery isolation tabs to apply power and send enrollment. If already powered, press and hold the light bulb and asterisk buttons together.

    Advanced Settings: Opt1 = OFF; Opt2 = OFF; Loop # = 1

    Note: Program the desired Area and User for arm/disarm functionality. If alarm activation on the asterisk button is desired, program the zone definition to the desired alarm type (Panic or Medical).