  • Ecolink WST-402 Wireless Tilt Sensor — Installation Guide

    August 31, 2026 2 min read

    Installation instructions for the Ecolink WST-402 Wireless Tilt Sensor — garage door position detection for 2GIG and Honeywell security panels.

    Full text manual (for reference)

    Installation instructions and user guide for the Ecolink WST-402 Wireless Tilt Sensor — a 345MHz wireless sensor designed to detect garage door position (tilt) for use with compatible security panels.

    Specifications

    • Frequency: 345MHz
    • Battery: One 3Vdc lithium CR123A (1550 mAh)
    • Battery life: 5-8 years
    • Operating temperature: -22°F to 120°F (-30°C to 49°C)
    • Operating humidity: 5-95% RH, non-condensing
    • Compatible receivers: 2GIG and Honeywell panels
    • Supervisory signal interval: ~60 minutes
    • Input type: Normally closed contact input terminals

    Enrolling the Sensor

    Set your alarm panel into program mode (refer to your panel's manual). The WST-402 has two triggers, each with a unique loop number: the built-in tilt sensor uses Loop 2, and the external contact input uses Loop 1.

    • Auto-enroll the tilt sensor: ensure the device is oriented with the tilt in the "up" position (note the arrow on the housing). When prompted by the panel, move the device until it's horizontal.
    • Auto-enroll the external contact input: when prompted by the panel, trigger the sensor by closing the circuit between the two terminal inputs (with a wire, or by applying the magnet to a hardwired contact).
    • Manual enrollment: use the serial number printed on the device.
    • The tilt sensor can be set as an "exit/entry" zone or a "perimeter zone" in your panel's zone type settings.

    Disclaimer: the external contact terminals, while functional, have not been submitted to UL/ETL for verification of compliance — their use falls outside the scope of this product's ETL listing.

    Tilt Sensitivity

    The sensor activates at approximately a 45-degree angle. Adjust sensitivity by moving the internal ball sensor up or down a few degrees. There is a built-in ~1 second delay to prevent false alarms from wind or vibration (common on large garage doors).

    Mounting

    Mounting screws and double-sided tape are included. For the tape: ensure the surface is clean and dry, apply the tape to the sensor and then to the mounting location, and press firmly for several seconds. Avoid taping below 50°F — the bond will still hold at low temperatures after 24 hours.

    Replacing the Battery

    A low-battery signal is automatically sent to the control panel when needed.

    1. Remove the screw securing the top cover, then remove the cover to expose the battery.
    2. Replace with a CR123A battery, ensuring the "+" side faces as indicated on the device.
    3. Reattach the cover and screw.

    Regulatory

    FCC ID: XQC-WST402 | IC: 9863B-WST402. Complies with FCC Part 15 (Class B) and Industry Canada license-exempt RSS standards. Changes or modifications not expressly approved by Ecolink could void the user's authority to operate the equipment.

    Warranty

    Ecolink Intelligent Technology Inc. warrants this product against defects in material and workmanship for 2 years from the date of purchase, limited to repair or replacement at Ecolink's option, returned to the original point of purchase. Excludes damage from shipping/handling, accident, abuse, misuse, improper maintenance, or unauthorized modification.