September 08, 2026 5 min read
Complete owner's manual and installation guide for the DynaQuip WaterCop Leak Stop+ automatic water shut-off system.
Owner's manual and installation guide for the DynaQuip WaterCop Leak Stop+ — an automatic water shut-off system that detects leaks and closes the water supply valve to prevent damage.
WaterCop Leak Stop+ detects water leaks in your plumbing system at a single location and automatically shuts off the water supply to that location. Early leak detection coupled with automatic water shut-off is the best way to prevent extensive water damage.
Repair parts (available from customer service, 800-545-3636) include the complete control box, replacement brass ball valve, and sensor cord/probe. The unit supports a maximum of 2 sensors.
Install the Leak Stop+ indoors, directly into the plumbing supply line just upstream of the appliance or area to be monitored, within reach of a 120 VAC outlet. The attached leak sensor is secured to the floor or catch pan where water would first accumulate — most commonly near a water heater.
Place the sensor probes flat on the floor or pan under the monitored appliance, in the areas where water would first accumulate. Avoid letting tape/adhesive touch or block the gold pins, and avoid contact between the gold pins and metal or other conductive surfaces (this can cause false alarms).
The Leak Stop+ constantly monitors the selected area for accumulating moisture. When water contacts a sensor probe, the control box closes the valve, shutting off the local water supply. The valve stays closed until manually reset via the green button, wall switch, or SmartConnect app. Lights indicate valve position (Red = Closed, Green = Open). The valve can also be controlled manually via the open/close buttons independent of a leak event. The unit requires an uninterrupted 120 VAC household outlet — during a power failure, the valve remains in its current position.
Leak Stop+ provides two alarm relay connections (dry-contact closure or 12 VDC signal) to report valve position, selectable via jumpers JP1 (dry contact) or JP2 (12 VDC live signal). When water is detected, the valve closes, the audible alarm sounds, indicator lights show CLOSED, and the alarm relays activate — this can trigger an auxiliary device such as a buzzer or light. A relay wire (12 VDC) is energized whenever the actuator is powered and closed; make connections to the relay coil terminals before energizing the actuator. To silence the alarm, press any button on the actuator face.
| Symptom | Checks |
|---|---|
| Leak sensor does not detect water | Verify power; verify gold prongs make continued direct contact with water; use tap water (not distilled/RO) when testing. |
| Red/green light does not illuminate | Verify the unit is plugged into a powered, grounded 120VAC outlet. |
| Motor does not open/close valve correctly | Verify power and correct valve-to-control-box orientation. If solder-connected, check the ball valve seats weren't heat-damaged. If compression-connected, check fittings weren't over-tightened. Remove the control box (retain O-ring/clip), use a flat-head screwdriver in the valve stem slot to verify the ball moves freely, then return the stem to line up with the actuator drive (perpendicular to pipe length). |
| Valve doesn't complete rotation / ALARM state | Both lights flash, alarm sounds, alarm relay activates — likely a blockage. Silence by pressing any actuator button, then check for valve obstruction per the motor troubleshooting above. |
This is an advanced automatic water shut-off system, but it does not guarantee protection against every possible water event. It will not detect water intrusion from external sources (rain, storm surge, sewer backup, pool/spa overflow, ice dams, HVAC condensation, etc.), requires power to operate, and is subject to component failure, power surge damage, or valve corrosion/blockage over time. Monthly testing is strongly recommended. This system is not a substitute for adequate homeowner's/property insurance.
Visit watercop.com for warranty information, or call 800-545-3636.