  • Danalock Universal Module V3 (Bluetooth) — DL0203130x Manual

    September 08, 2026 2 min read

    Instruction manual for the Danalock Universal Module V3 — a Bluetooth-enabled dual-relay module.

    Full text manual (for reference)

    Instruction manual for the Danalock Universal Module V3 — a Bluetooth-enabled dual-relay module for integrating access control devices, gates, or other equipment with smart home gateways.

    Specifications

    Operating Voltage Range 12-24V DC
    Max Input (at 24V) 100mA
    Number of Relays 2
    Type of Relays Potential-free contacts (NO/NC)
    Power Output +4dBm
    Max Relay Voltage 48V
    Wireless Communication Bluetooth® 4.2 Low Energy
    Bluetooth® Range 5 - 10 meters

    Wiring

    Set up the Universal Module according to the wiring schematic. Use Relay 1 before Relay 2 if possible. Terminal connections, top to bottom:

    • Ground
    • Power output, 12-24V DC, 1 amp
    • Relay 2: Normally Open
    • Relay 2: Common
    • Relay 2: Normally Closed
    • Relay 1: Normally Open
    • Relay 1: Common
    • Relay 1: Normally Closed
    • Power input, 12-24V DC, 1 amp
    • Ground

    Click Commands

    Configure the Universal Module via the recessed button. Press the button the number of times shown below, then wait 5 seconds for the module to react. If an incorrect number of clicks is made, stop at an unmarked count and wait 5 seconds — the LED flashes red and no change is made.

    Clicks LED Color Activity
    1 Green Inclusion mode — pairs the module with a smart home gateway such as Z-Wave or ZigBee (not HomeKit). The module blinks green and has 30 seconds to pair/unpair with a gateway.
    10 Red Reset — deletes all settings and keys on the Universal Module. The module blinks red to confirm.

    LED Signal Reference

    LED Mode Status Indication
    3 sec constant white Power on
    Constant purple Firmware update activated
    Blinking blue light Settings changed
    5 sec blinking white light Identify
    5 sec constant red Factory reset
    5 sec constant green, followed by green blinks Inclusion mode activated

    Poly-Control ApS — Gammel Stillingvej 427C, 8462 Harlev, Denmark — +45 4242 8122 — info@danalock.com — www.danalock.com