  • Channel Vision A0304 Audio & IR Control CAT5 Transceiver Kit — Instructions

    September 08, 2026 4 min read

    Instruction manual for the Channel Vision A0304 Audio & IR Control CAT5 Transceiver Kit, sending balanced audio and IR over up to 1,000 ft of CAT5 cable.

    Full text manual (for reference)

    Instruction manual for the Channel Vision A0304 Audio & IR Control CAT5 Transceiver Kit, which sends balanced audio and IR signals over up to 1,000 feet of CAT5 cable using decorator-style wall plates.

    Overview

    The A0304 Audio & IR Control CAT5 Transceiver Kit can deliver balanced audio and IR signals over 1,000 ft of CAT5 cable — a convenient way to send noise-free audio over cabling that already exists in the home. The decorator-style wall plates flush-mount into the wall and blend into modern décor. The low cost, simplicity, and availability of CAT5 cable make the A0304 a convenient choice for both new construction and retrofit applications.

    Features

    • Easy to install and use
    • Transport audio from a bedroom back to your main entertainment system
    • Control the audio device in the bedroom from your entertainment room
    • Sends line-level audio over 1,000 ft. of category cable
    • Compatible with Category 5, 5e, and 6 wiring

    Kit Contents

    A0304 Input Wall Plate — connections: IR Receiver Input, IR Emitter Output, Audio Input, CAT5 Outputs (use only one, not both).

    A0304 Output Wall Plate — connections: IR Receiver Input, Power Supply Input, Audio Input, Rear Power Input, Rear Power Loopout, CAT5 Outputs (use only one, not both).

    Installation

    • Both the input and output wall plates mount into a standard single-gang low-voltage ring, using the included mounting screws. A standard decorator trim plate (not included) covers each unit.
    • Connect the power supply to the output wall plate; run CAT5 cable (up to 1,000 ft.) between the input and output wall plates.
    • The power for the A0304 can be looped so that one power supply serves up to 10 units. The power supply can be connected in the front or the rear.

    Basic Application

    An audio source (e.g., a CD player) connects to the input wall plate's Audio In jacks. The signal travels over CAT5 (up to 1,000 ft.) to the output wall plate, which feeds an audio amplifier. An optional additional IR receiver can be connected at the input side to allow control of the audio device even if it's behind a closed cabinet door; a standalone IR receiver or IR output from a whole-house IR system can be connected at the output side.

    Advanced Application

    When used with an A4623 or A4603 multi-source audio distribution system, connect the RCA outputs to the source "Input" jacks and connect the "IR In" jack to any of the IR Emitter output jacks using an IR-4180 cable. This lets the remote audio source be listened to and controlled from any audio zone — the IR receiver in the audio system keypads passes IR signals back to the input wall plate.

    Pin-Out Configuration (TIA-568A)

    Pin Wire Signal
    1 Green Solid Left +
    2 Green Stripe Left -
    3 Orange Solid Right +
    4 Blue Solid IR Signal
    5 Blue Stripe Ground
    6 Orange Stripe Right -
    7 Brown Solid Ground
    8 Brown Stripe Power +

    Troubleshooting

    • Be sure the CAT5 cable is wired correctly. Follow the TIA-568A standard at both ends — incorrect wiring can cause distorted sound or prevent the system from working at all.
    • Be sure speakers are connected in phase (check the product label). Out-of-phase speakers can deprive the system of bass, especially with dual-voice-coil speakers.
    • Trouble with IR control? Make sure your IR remote can control the source device directly (not via the IR repeating system). Verify the IR emitter is sending a signal — many IR emitters emit invisible light; you can see it through a digital camera's viewfinder (turn the lights off to help). If troubleshooting an external IR receiver with a feedback LED, confirm the LED flashes when pressing remote buttons — if not, try new batteries in the remote.
    • Observe wiring distance specs: max recommended length between wall dock and output wall plate is 1,000 feet. The A0304 may work farther, but extreme distances aren't recommended due to power loss over the CAT5 wire.
    • For further help, contact Channel Vision technical support or visit www.channelvision.com.

    Specifications

    • THD + Noise: <0.2%, 20Hz–20kHz
    • Signal/Noise: >-96dB
    • Frequency Response: 20Hz–20kHz +/- 0.3dB
    • Input Impedance: 20k Ohms
    • Output Impedance: 600 Ohms
    • Power Requirements: 15VDC @ 0.075A (75mA)
    • Power Supply: 15VDC @ 850mA
    • Wire type: 4-pair, UTP Category 5, 5e or 6
    • Maximum Cable Run: 1,000 ft. over CAT5

    Specifications subject to change without notice.

    Warranty

    Channel Vision Technology will repair or replace any defect in material or workmanship occurring during normal use, with new or rebuilt parts, free of charge in the USA, for one year from the date of original purchase — a no-hassle warranty, no mail-in card needed. Does not cover shipping damage, failures caused by third-party products, or failures due to accident, misuse, abuse, or alteration. Extended only to the original purchaser, with proof of purchase required. Mail-in service: call (800) 840-0288 toll free for a Return Authorization number.

    Channel Vision products are not intended for use in medical, lifesaving, life-sustaining, or critical environment applications.

    Contact