August 31, 2026 3 min read
Installation manual for the Cabletronix CTHDA-1P, CTHDA-2P, and CTHDA-1A wall-mounted 1GHz multi-media drop amplifiers for CATV systems.
The Cabletronix CTHDA-1P, CTHDA-2P, and CTHDA-1A are wall-mounted 1GHz multi-media drop amplifiers for CATV systems requiring two-way multi-media networking. They're low-noise amplifiers with high port-to-port isolation, 6KV surge protection on all ports, electrostatic discharge protection, and a zinc die-cast housing to prevent RFI. They can be remotely powered over coax, line-powered through an RF port, or externally powered through a dedicated "power-in" port.
| Parameter | CTHDA-1P | CTHDA-2P | CTHDA-1A |
|---|---|---|---|
| Input ports | 1 | 1 | 1 |
| Output ports | 1 | 2 | 1 |
| Forward path | 54–1,000 MHz | 54–1,000 MHz | 54–1,000 MHz |
| Reverse path | 5–42 MHz | 5–42 MHz | 5–42 MHz |
| Forward gain | 13.5dB | 10dB | 14dB |
| Reverse gain (loss) | -1.6dB | -5dB | 10dB |
| Isolation (out-out) | N/A | 18dB minimum | N/A |
| Noise figure | 3dB typical, 4dB max | 3dB typical, 4dB max | 3dB typical, 4dB max |
| Return loss (in-out) | 18dB typical | 18dB typical | 18dB typical |
| Power supply voltage | 12–16V, 200mA | 12–16V, 200mA | 12VDC, 300mA |
| Surge protection (all ports) | 6KV | 6KV | 6KV |
| Connections | F Type Female | F Type Female | F Type Female |
| Impedance | 75 Ohms | 75 Ohms | 75 Ohms |
| Operating temperature | -40°C to +60°C | -40°C to +60°C | -40°C to +60°C |
System installer must adhere to Article 820-40 of the NEC, which provides guidelines for proper grounding and specifies that the cable ground shall be connected to the grounding system of the building, as close to the point of cable entry as practical.
Each unit ships fully assembled and factory tested. Ensure all accessories are removed from the container before discarding packing material.
Inspect front and rear for shipping damage. Confirm the equipment is clean and no connectors are broken, damaged, or loose. Contact 1-610-429-1511 if damage is found.