September 08, 2026 3 min read
Technical information and instructions for the Bellman & Symfon Visit Portable Receiver (BE1033), a light/sound/vibration alerting receiver.
Technical information and instructions for the Bellman Visit Portable Receiver (BE1033) — an indoor receiver in the Bellman Visit alerting system that signals via light, sound, and optional bed-shaker vibration.
The BE1033 Bellman Visit Portable Receiver attracts attention using light, sound, and optionally vibration (via the Bellman Bed-shaker BE1270 accessory). It's activated via radio signals from any transmitter in the Bellman Visit System, or via a door with an external trigger.
To test the receiver's radio reception, set the transmitter in the Bellman Visit System to the same channel as the portable receiver, then press the transmitter test button. The receiver will respond with:
Pressing the receiver's own test button briefly activates it the same way. When activated via an external trigger, it responds identically.
All Bellman Visit System units ship factory-tuned to channel 0 (all channel switches in the "off" position).
Note: All Bellman Visit products in the same system must be tuned to the same channel to operate as a group — except the Bellman Visit Fire Alarm Transmitter, which has no adjustable channel. As a safety precaution, the receiver will sound on any detected fire alarm signal, regardless of its programmed channel.
| Problem | Solution |
|---|---|
| Receiver does not receive signals from door or telephone transmitters | Press the receiver test button briefly — the test light should show green with a light and sound signal. If red lights up or nothing illuminates, replace the batteries. Also check the receiver isn't placed too far from the transmitter. |
| Receiver emits a signal even though neither the door nor telephone is active | Change the radio channel on all Visit System receivers and transmitters. |
| Receiver emits sound but no light signal | Check that the light signal switch (item 7) is set to "on." |
| Spec | Value |
|---|---|
| Mains power | 6V DC / 800mA via power supply unit BE9018 (Europe) or BE9083 (United Kingdom) |
| Battery power | 4 x 1.5V LR14 (C) Alkaline |
| Operating time (alkaline) | Approximately 1 year |
| Power consumption | Active: 350mA; Idle: 430µA |
| Radio frequency | 433.92 MHz |
| Number of channels | 64 logical channels |
| Coverage | ~80 metres with clear line of sight; reduced by walls/large objects, greatly reduced by reinforced concrete |
| Activation | Radio (Bellman Visit System) or external trigger via the rear screw connection box |
| Built-in sound signal | 90 dBA maximum at 1 metre; main frequency range 500–1000 Hz |
| Vibrator power | 2.0–4.0 VDC |
| Use | Indoor use only |
| Dimensions (W x H x D) | 130 x 165 x 36 mm |
| Weight | 600g with battery; 330g without |
| Colour | White with red volume control |