September 08, 2026 2 min read
Step-by-step procedure for physically replacing an ABB free@home/Welcome 7" indoor panel in an existing programmed installation.
Step-by-step guide for physically replacing an ABB free@home®/Welcome 7" Panel (indoor station) in an existing, fully-programmed installation — either as a physical device swap or to copy a single device's configuration to a new one.
This procedure applies after a physical panel replacement, and works the same way when copying settings for a single device in an existing project. The advantage: replacing a device in an already-programmed project takes only a few seconds once the physical swap and re-addressing are done.
Note: To protect the panel from unauthorized replacement, the fuse feeding the Welcome system must be turned off and back on — this is the only way to restore full functionality, including the door handle and door opener.
These instructions apply to a combi actuator and are also valid for the free@home® panel.
Doc. No. 9AKK106930A6026, Rev. 1.1 — ABB Global Support, free@home Door Entry Systems.