September 08, 2026 4 min read
Product manual for the ABB-free@home™ TH-1.1 Thermostat (ABTH11).
Product manual for the ABB-free@home™ TH-1.1 Thermostat (model ABTH11) — a touchscreen thermostat for the ABB-free@home smart home system, covering setup, configuration, wiring, and resetting.
Always-on functions: a proximity sensor near the bottom of the device wakes up the display and shows touch controls as a hand approaches; the display also self-adjusts brightness to room light level.
Warning: Installation must be performed by a licensed HVAC installer or electrical professional. Improper installation can cause property damage, personal injury, or loss of life. After wiring, take a photo of the connected wires for future reference.
When first powered, the device enters discovery mode for 30 minutes, during which the SysAP can find and connect to it. To add the device:
Option 1: Two or more Thermostats controlling the same HVAC equipment — designate one as "Master" (control wires connect here) and the other(s) as "Slave" (only need 24V AC on Rc/C terminals). Master and Slave display the same information.
Option 2: Two or more separate HVAC systems (e.g. one per floor) — configure each Thermostat independently as "Thermostat."
| Setting | Purpose | Options / Range |
|---|---|---|
| Heating system, stage 1/2 (W1/W2) | Defines heater type controlled by W1/W2 wires | None, Natural Gas, Heat Pump, Propane, Oil, Electric, Hydro underfloor/radiator |
| Cooling system, stage 1/2 (Y1/Y2) | Defines device controlled by Y1/Y2 | None, Air conditioning, Heat pump |
| Heat pump reversing valve (O/B) | Defines reversing valve polarity for heat pumps | On cool / On heat |
| Type of accessory (ACC) | Defines device controlled by AUX/ACC wire | Humidifier (evaporative/steam), Dehumidifier (active open/closed), Manual (active open/closed) |
| Compressor delay between cycles | Minimum wait before A/C or heat pump runs again | 120-360 sec, increments of 10 |
| Fan timer after heating/cooling | Fan run time after heat/cool shuts off | 60-240 sec, increments of 10 |
| Fan delay ON heating/cooling | Delays fan start to avoid cold/warm air blasts | 0-240 sec, increments of 10 |
| Go directly to 2nd stage after... if difference >5°F | Switches to 2nd stage if 1st stage can't reach setpoint | 30-360 sec, increments of 10 |
| Fan control | Whether Thermostat or HVAC equipment controls the fan | Thermostat-controlled (safest) / Equipment-controlled |
| Protection: Force cooling/heating if temp exceeds/falls below | Home protection triggers | 86-104°F (cooling) / 34-50°F (heating) |
| Max compressor/heating cycles per hour | Limits compressor switching to save energy and reduce wear | 1-6 (cooling), 1-12 (heating) |
| Switching delay between heating and cooling | Controls how quickly the system swaps modes | None, Low, Medium (recommended), High |
| User Mode | Controls which icons/settings appear on main screen | Normal User (default) / Power User |
| Spec | Value |
|---|---|
| Operating Voltage | 24V AC, 60 Hz — DO NOT connect to voltage above 24V |
| Wires | AWG18 to AWG22; stranded wires are NOT allowed |
| Wireless Protocol | free@home, 2.400-2.483 GHz, meshed |
| Ambient Operating Temperature | 32°F to 104°F (0°C to 40°C) |
| Terminal | Conventional Setup | Heat Pump Setup |
|---|---|---|
| Rc | Cooling power, 24V AC | Cooling power, 24V AC |
| Rh | Heating power, 24V AC | Heating power, 24V AC |
| C | Common, 24V (from Rc) | Common, 24V (from Rc) |
| Y1 / Y2 | Cooling stage 1 / 2 | Heat pump compressor stage 1 / 2 |
| G | Fan | Fan |
| W1 / W2 | Heating stage 1 / 2 | AUX heating stage 1 / 2 |
| ACC | Accessories (AUX symbol on display) | Accessories (AUX symbol on display) |
| O/B | Not used | Reversing valve |
If heating and cooling systems use separate 24V AC ("2-transformer system"), remove the jumper on the back of the Thermostat.
Reset the Thermostat if it was previously assigned to a different System Access Point (SysAP) — this removes the previous connection and lets the device connect to a new SysAP. To reset: touch and hold the power OFF button for at least 15 seconds until the Thermostat reboots.
Customer Service: 800-816-7809 (7:00am-5:30pm CST, Mon-Fri) · Technical Support: 888-385-1221, Option 1 (7:00am-5:00pm CST, Mon-Fri) · freeathome_techsupport@us.abb.com