Complete instruction guide for the LifeSource UB-512 AM/PM Memory Wrist Blood Pressure Monitor.
Complete instruction guide for the LifeSource (A&D Medical) UB-512 AM/PM Memory Wrist Blood Pressure Monitor — setup, taking a measurement, memory functions, blood pressure reference tables, troubleshooting, and specifications.
The UB-512 provides accurate readings on wrists with a circumference between 5.3" and 8.5" (13.5–21.5 cm). It requires two "AAA" (1.5V) batteries (included).
Press the AM START or PM START button depending on time of day. The reading is stored into the appropriate memory (up to 30 readings per button).
Press and hold the AM START or PM START button; release after the first recalled reading appears. Measurements display from most recent to oldest.
Remove batteries to clear both AM and PM memory. Reinsert batteries to resume.
Press both AM START and PM START buttons simultaneously. A reading is taken but not stored — useful when other people's readings would skew your average.
Note: To stop inflation at any time, press either START button. Poor circulation (e.g., cold hands/wrists in winter) may prevent an accurate reading.
An irregular heartbeat symbol appears if a heartbeat varies by 25% or more from the average of all heartbeat intervals during measurement. Relax, remain still, and avoid talking during measurement. Contact your physician if this symbol appears frequently.
The Cuff Inflation Meter (left side of display) shows inflation progress; it starts inflating slowly at 20mmHg. The Average Reading feature displays your average blood pressure based on all readings stored in memory, shown briefly during measurement and when recalling memory.
Provides a quick visual classification of your blood pressure reading based on the JNC7 Classification (Seventh Report of the Joint National Committee on Prevention, Evaluation and Treatment of High Blood Pressure, National Heart, Lung and Blood Institute — May 2003). It is approximate; other risk factors (diabetes, obesity, smoking) also affect blood pressure. Consult your physician for interpretation. Residents outside the U.S. (Canada, Mexico) should use the WHO Classification Table below.
| Classification | Systolic (mmHg) | Diastolic (mmHg) |
|---|---|---|
| Normal | less than 120 | and less than 80 |
| Prehypertension | 120–139 | or 80–89 |
| Stage 1 Hypertension | 140–159 | or 90–99 |
| Stage 2 Hypertension | ≥160 | or ≥100 |
| Classification | Systolic (mmHg) | Diastolic (mmHg) |
|---|---|---|
| Optimal | less than 120 | and less than 80 |
| Normal | less than 130 | or less than 85 |
| High-Normal | 130–139 | or 85–89 |
| Stage 1 Hypertension | 140–159 | or 90–99 |
| Stage 2 Hypertension | 160–179 | or 100–109 |
| Stage 3 Hypertension | ≥180 | or ≥110 |
Blood pressure is affected by age, weight, time of day, activity, climate, altitude, season, caffeine/alcohol, medications, emotional stress, and tight clothing. Walking can raise systolic pressure ~12 mmHg and diastolic ~5.5 mmHg; sleeping can lower systolic pressure by up to 10 mmHg. Hypertension (consistently elevated readings) is often called a "silent killer" since it may not produce symptoms, but is treatable when caught early — the American Heart Association recommends not smoking, reducing salt/fat intake, maintaining proper weight, exercising routinely, and getting regular physical checkups.
Why home readings differ from clinical readings: office/hospital readings can be elevated due to anxiety ("white coat hypertension"). Cuff size also affects readings — a cuff too large reads low, too small reads high. For the most useful history, establish a consistent two-week "baseline measurement" routine (same time, position, chair, cuff) and record readings as systolic/diastolic (e.g., 120/80) with pulse noted as "P 72".
| Problem | Probable Cause | Corrective Action |
|---|---|---|
| Nothing appears in display | Batteries drained, or terminals misaligned | Replace batteries (alkaline recommended); check terminal polarity |
| Cuff does not inflate | Battery voltage too low | Replace all batteries |
| Unit does not measure | Cuff not fastened properly | Fasten cuff correctly |
| Readings too high or low | Movement during measurement, or incorrect cuff position | Remain still and quiet; keep cuff level with heart |
| Different value than clinic reading | Different cuff size used, or white coat hypertension | See "Why readings differ" guidance above |
If these steps do not solve the problem, call 1-888-726-9966 (Canada: 1-800-461-0991). Do not attempt to repair the device yourself.
This LifeSource blood pressure product is covered by a Lifetime Warranty (see warranty card for details; register at www.LifeSourceOnline.com). For support, contact A&D Medical's LifeSource Health Line at 1-888-726-9966 (U.S.) or Auto Control Medical at 1-800-461-0991 (Canada).