    Installation and Programming Instructions for the Yale nexTouch Sectional Mortise NTM6 Touchscreen and Push Button Keypad Lock.

    Full text manual (for reference)

    Installation and Programming Instructions for the Yale nexTouch Sectional Mortise NTM6 Touchscreen and Push Button Keypad Lock. This is a highly illustrated mortise lockset guide; the page below focuses on programming, factory settings, and troubleshooting — full illustrated mechanical installation steps (handing, drilling, lockbody, escutcheon assembly) are in the downloadable PDF.

    Important Notice

    Retrofitting or modifying this product may impact fire rating, safety features, and warranty. Consult code specifications to ensure compliance with all applicable codes and ratings.

    Determining Handing

    The hand of the door is determined from the secure side (the side from which you unlock and enter). The RED locking slide should face the secure side of the door. The latchbolt's beveled edge must face the strike — see the full PDF for the latchbolt reversal procedure if needed. A key cylinder is used for cylinder-option installations; a thumbturn is used when the mortise lock is equipped with a deadbolt.

    Creating the Master PIN Code

    A Master PIN Code must be created upon installation or after a factory reset — the lock cannot be programmed or used until this step is completed.

    1. Activate the lock (touch the screen).
    2. Follow the prompt: "Register Master Code. Press the gear key to continue."
    3. Enter a 4-8 digit Master PIN Code, then press the gear key.
    4. Indicate deadbolt configuration: press "1" if a deadbolt is installed, or "3" if not, then press the gear key.
    5. The lock confirms "Registered" then "Completed."

    Max User Codes: 100 without the optional Radio/Network Module, or 500 with the Radio Module installed.

    Creating User PIN Codes

    The Master PIN code must be created first.

    1. Activate the lock, enter the Master PIN code, then press the gear key. Lock responds "Menu mode, enter number."
    2. Press "2" for "Register User code," then press the gear key.
    3. Press "1" to register a code.
    4. Enter a 4-8 digit PIN code, then press the gear key. Lock responds "Registered. Press the check key to complete. Press the gear key to continue."
    5. To add more codes: press the gear key again, enter another 4-8 digit code, and repeat.
    6. To finish: press the check key — lock responds "Completed."

    Locking & Unlocking

    • With One Touch Locking Enabled: Enter a registered PIN code and press the check key to unlock.
    • Privacy Button: A single press locks the door. Press and hold to activate Privacy Mode.

    Resetting the Lock to Factory Default

    Warning: Resetting deletes ALL user codes (including the Master PIN code) and resets all programming to factory defaults.

    1. Remove the battery cover with the supplied hex wrench and remove the batteries.
    2. Using a #2 Phillips screwdriver, remove the interior escutcheon from the door to access the reset button on the back (cables may stay connected).
    3. Reinstall the four AA batteries.
    4. Press and hold the reset button for 3 seconds.
    5. While still holding the reset button, temporarily remove one AA battery.
    6. Reinstall the battery.
    7. Release the reset button and wait ~15 seconds — the speaker announces "Welcome to Yale."
    8. Reassemble the escutcheon by reversing steps 1-2.

    After a reset, creating a new Master PIN Code is the only option available and must be done before any other programming.

    Factory Settings

    Setting Factory Default
    Master PIN Code Registration required
    All Code Lockout Disabled
    Automatic Relock Disabled
    Escape Return Mode Disabled
    Inside Indicator Light Enabled
    Language Setting English
    One Touch Locking Enabled
    Privacy Button Mode Disabled
    Shutdown Time 60 Seconds
    Volume Setting High
    Wrong Code Entry Limit 5 Times

    Key Definitions

    • All Code Lockout Mode: Enabled by the Master code; restricts all user (non-Master) PIN access. A red locked padlock appears on-screen when active.
    • Automatic Re-lock Time: After a successful unlock, the lock automatically re-locks after 5 seconds (or a custom duration set via Menu #3 → #1).
    • Eco Mode: Puts the unit in low-power mode to extend battery life.
    • Escape Return Mode: When enabled, prohibits automatic locking — the door must be physically manipulated to re-lock once opened from inside.
    • Low Battery / 9V Override: Low battery flashes the RED warning indicator. If power is fully lost, apply a 9V battery (either direction) to the touchscreen's override terminals for emergency power, then enter your PIN to unlock.
    • Passage Mode: Lock remains unlocked/open until Passage Mode is disabled.
    • Privacy Button Mode: With an optional Door Position Switch installed and the door closed, a 3-second press disables all keypad functions until the door opens again.
    • Shut Down Time: After 5 failed PIN attempts, the unit shuts down for 60 seconds (keypad flashes during this time).
    • Tamper Alert: Sounds an audible alarm if someone attempts to forcibly remove the outside lock from the door.

    Feature Programming Through Menu Mode

    To access: touch the screen, enter the Master PIN code, press the gear key. The lock responds "Menu mode, enter number." Key menu branches include:

    • 1 — Master PIN Code Setting
    • 2 — Register User or Passage Codes (User Code, Passage Code, Delete a Code)
    • 3 — Advanced Lock Settings: Automatic Re-lock (1-180 sec or Disable), Inside Indicator Light (Enable/Disable), One Touch Locking (Enable/Disable), Privacy Button Mode (with/without Deadbolt options), Configure Deadbolt (Included/Not Included), Escape Return Mode, Eco Mode
    • 4 — Volume Setting: High / Low / Silent
    • 5 — Language Setting: English / Spanish / French
    • 6 — All Code Lockout: Enable / Disable
    • 7 — Network Module Setting (appears only with Network or Yale Accentra Key module installed): Join the network / Exit the network

    Programming Troubleshooting

    Symptom Suggested Action
    Lock does not respond (door open, accessible) Touch with a larger area of the hand (at least 3 contact points); check battery installation/polarity/condition; check touchscreen cable connection.
    Lock does not respond (door locked, inaccessible) Batteries may be fully discharged — apply a 9V battery to the touchscreen terminals for emergency power.
    Chimes on code acceptance but door won't open Check for another locking device (e.g., deadbolt); check door gaps for obstructions; verify the motor cable is connected to the "MOTOR" PC board terminal; check the locking slide moves freely.
    Won't automatically re-lock Check whether Auto Re-lock Mode is enabled; check the low-battery indicator and change batteries if lit.
    PIN codes won't register Codes must be 4-8 digits; the same code can't be reused across users; only the Master can manage registration; codes must be entered within 20 seconds; the check/gear keys can't be part of a PIN.
    "Invalid code" or times out Check if All Code Lockout Mode is enabled — only the Master can disable it.
    No sound on operation Check if Volume is set to Silent.
    "Low Battery" response Replace all four AA Alkaline batteries.
    "Wrong number of digits" Re-enter 4-8 digits followed by the check key.
    Won't enter Privacy Mode Verify it's enabled; check door gap; hold the Privacy Button longer.

    Note: When batteries are replaced on Network Module locks, the real-time clock must be re-verified through the User Interface — especially around Daylight Saving Time transitions.