  • X10 PRO Powerflash Security Interface Module (PSC01) — Instruction Manual

    September 08, 2026 2 min read

    Complete instruction manual for the X10 PRO Powerflash (PSC01/XPPSC01) plug-in burglar alarm interface module.

    Full text manual (for reference)

    Complete instruction manual for the X10 PRO Powerflash (PSC01/XPPSC01) plug-in burglar alarm interface module.

    Overview

    The Powerflash module interfaces conventional security systems, and other contact/voltage-output devices, into X-10 PRO powerline-controlled products — letting an alarm event turn on lights, flash lights, or activate wired-in sirens.

    Input Configurations

    The unit provides terminals for two input configurations, selected via the INPUT slide switch:

    Switch Position Input Type
    A 6–18VDC
    B Dry contact closure (Form "C")

    Setting Up the Powerflash Module

    • Using a small screwdriver, adjust the code wheels to the desired house code and unit code.
    • Adjust the MODE slide switch to select the desired mode of operation (see table below).
    • Connect the terminals on the Interface to the burglar alarm or output device, such as a driveway sensor or similar contact closure. Observe the polarity shown in the diagram if the alarm output is DC voltage.
    • Plug the Interface into a 120V AC wall outlet.

    Mode Switch Settings

    Mode Behavior
    1 Turns on all Lamp modules (including wall switches) set to the same house code as the interface. Also turns on Appliance modules set to the same house code and unit code as the Interface. When the alarm is reset, only the modules set to the same house and unit code as the Interface are turned off.
    2 Flashes all Lamp modules (including wall switches) set to the same house code as the Interface. When reset, all lights and wall switches stay on.
    3 Turns on Lamp and Appliance modules set to the same house code and unit code as the Interface. When reset, turns the same module off.

    Testing the Interface

    • Press TEST to activate the Interface according to the selected mode.
    • Press ALL UNITS OFF to switch off modules left on after activating the Interface.

    Support

    Technical Support: 800-832-4003