Installation instructions for the WGL Rain8net Pro2 master module — a modular 8-zone sprinkler controller driven via RS232 serial port.
Installation instructions for the WGL Rain8net Pro2 master module — a modular 8-zone sprinkler controller driven via RS232 serial port, expandable to control up to 32 irrigation zones by daisy-chaining additional modules.
Additional units may be daisy-chained to provide control and 24VAC power to as many as 32 irrigation zones from a single COM port. Important: any expansion module added must be identified as a "Pro2 expansion" to remain compatible with this master module.
A 12-position terminal strip is found on all modules. Connect the 24 VAC transformer to this terminal strip only on the first module — remaining modules in the chain are powered over the 8-conductor network cable, which also carries communications.
Connect a rain sensor or flow meter using the 3.5mm phono jack to the right of the RJ45 jacks. The input feature accepts only passive contact closure devices — do not connect to anything powered.
Necessary only if default settings are not used. Rain8net modules ship with an address of "1" and default run timers disabled — for most 8-zone, single-module setups this is the desired configuration and hardware installation is complete without further configuration.
Important: only one module should be connected to the PC during configuration.
The Rain8 features a status LED visible on top of the unit.
| LED State | Meaning |
|---|---|
| No LED | Verify the 24VAC transformer is connected to the last two terminals on the detachable terminal strip. |
| Steady LED | Everything is working okay — no incoming commands. |
| Long blink off (1–2 sec) | Normal operation — incoming command detected with an enabled address. The specified zone's LED will be on and 24VAC present between that zone terminal and common. |
| Short blink off (½ sec) | Incoming command detected with an address that is NOT enabled. |