    Complete owner's manual for the Speco Technologies O2VLB2 full HD IP bullet camera.

    Full text manual (for reference)

    Owner's manual for the Speco Technologies O2VLB2 Full HD IP Bullet Camera — a multi-codec (H.264, MJPEG) network camera with built-in IR LEDs, IP66-rated housing, and PoE support.

    Overview

    The O2VLB2 integrates traditional camera and network video technology to enable real-time transmission of synchronized full HD video. Built-in IR LEDs provide suitable imaging in low-light environments, and the IP66-compliant housing supports outdoor installations. Built-in PoE (Power over Ethernet) reduces the wiring required during installation.

    Specifications

    Image sensor Progressive scan 1/3-inch CMOS
    Day/Night mode IR-cut filter
    Gain control Fixed/Auto
    White balance Manual/Auto
    BLC On/Off
    Electronic shutter Manual/Auto/Low noise/Low motion blur; range 1/3 to 1/100000
    Video compression H.264/H.264B/H.264H/MJPEG
    Supported resolutions Main stream: 1920x1080 / 1280x720 @30fps; Sub stream: 704x576 / 704x480 @30fps
    Video bit rate VBR/CBR; H.264H: 16Kbps–8192Kbps; MJPEG adjustable
    Video flip Mirror and flip
    Privacy mask Supports up to 4 privacy mask zones
    Video information Channel title, time title, motion detection, tampering
    Lens 3.6mm fixed
    Ethernet 10/100 Base-T
    Network protocols HTTP, TCP, ARP, RTSP, RTP, UDP, RTCP, SMTP, FTP, DHCP, DNS, DDNS, PPPoE, IPv4/v6, QoS, UPnP, NTP, HTTPS, Bonjour
    User access Max 20 users
    Security User ID & password protection, IP address filtering, HTTPS, user access log
    IR range 65' (scene-dependent)
    Power PoE (802.3af), 12VDC
    Power consumption 6W max
    Operating temperature -22°F ~ 140°F
    Operating humidity ≤95%
    Dimensions 2.6" (diam) x 6.1" (L)
    Unit weight 1.4 lbs

    Cable Connections

    Port Function Connection Note
    LAN Network port Ethernet port Connect to standard Ethernet cable for power and data
    DC 12V Power input port DC jack Power port. Input DC 12V

    Installation

    Important: Make sure the installation surface can support a minimum of 3 times the weight of the camera.

    1. Put the installation template on the designated surface (wall or ceiling).
    2. Drill holes according to the positions on the installation template.
    3. Open the accessories bag, take out the expansion bolts, and insert them into the drilled holes.
    4. Take out the screws and tighten the 4 screws to fix the device to the installation surface. The sun shield can be adjusted — tighten its screws when finished.
    5. Connect all applicable wiring properly.
    6. Use a Phillips head screwdriver to loosen the adjusting screw.
    7. Adjust the device to point at the desired angle.
    8. Use the Phillips head screwdriver to tighten the screws.

    IP Scanner

    The IP Scanner utility searches for the device on the local network (only devices on the same subnet can be discovered). The device list shows the IP address, model number, and MAC address of each device found — select the applicable device and double-click to open the web viewer.

    Web Operation

    Open a browser and enter the camera's IP address in the address bar, or double-click the device in IP Scanner. At the login screen, enter your username and password — default username is admin and default password is 1234. For security, change the password after initial login. After logging in, follow the prompts to install any applicable browser plugins.

    FAQ / Troubleshooting

    Water leakage has occurred Removal of the front or rear cap may result in water leakage; check for heavy impact to the glass front cap or a loosened waterproof plug on the rear cap.
    IR video is poor Insufficient power may prevent the IR LEDs from functioning properly; the object may be outside the IR distance range of the device.
    Cannot log in to the web viewer ActiveX control may be blocked; graphics card may need DirectX 8.1 or higher; check network connection, network setup, and username/password.
    Settings updates After modifying important camera settings, reboot the device to ensure the new settings are applied.

    Important Safeguards

    • All installation and operation must conform to local electrical safety codes; use a certified/listed 12VDC Class 2 power supply only. Do not connect two power sources to the device simultaneously. The product must be grounded to reduce shock risk.
    • Avoid heavy stress, violent vibration, or water exposure during transportation, storage, and installation.
    • Do not apply power before completing installation; install a proper power cut-off device during connection.
    • Installation, examination, and repair should be done only by qualified personnel; unauthorized changes could void the warranty.
    • Install in a cool, dry place away from direct sunlight and heat sources; avoid extreme temperatures and electromagnetic radiation (which may cause CMOS sensor failure); don't block ventilation openings or allow water/liquid intrusion.
    • Before maintenance, shut down the device and unplug the power cable. Do not touch the CMOS sensor optic component — use a blower for lens dust. Use a dry soft cloth (or slightly dampened with neutral detergent) to clean the device; use professional optical cleaning methods for the enclosure to avoid impairing IR functionality.

    Manufacturer