Installation instructions for the Sentrol/GE Security ShatterPro II Advanced Acoustic Glassbreak Sensor with Pattern Recognition Technology (recessed and surface mount models).
Installation instructions for the Sentrol/Interlogix ShatterPro™ II Advanced Acoustic Glassbreak Sensor with Pattern Recognition Technology — available in recessed (5820A/5822A) and surface mount (5812A/5812EZ/5815A/5815EZ) models. Protected under U.S. Patents 5,192,931 and 5,510,767.
| Description | Model No. | Listing |
|---|---|---|
| ShatterPro II EZ, tamper, latch or non-latch LED | 5812EZ-W | UL |
| ShatterPro II EZ, tamper, Form C, latch or non-latch LED | 5815EZ-W | ULC |
| ShatterPro II, tamper, latch or non-latch LED | 5812A-W | UL |
| ShatterPro II, tamper, Form C, latch or non-latch LED | 5815A-W | ULC |
| Recessed ShatterPro II, latch or non-latch LED | 5820A-W | — |
| Recessed ShatterPro II, tamper, latch or non-latch LED | 5822A-W | UL |
| Single Gang Box ShatterPro II | 5825A-W | — |
| Single Gang Box Kit for Recessed ShatterPro II | 5829A-W | — |
| Hand-held Tester (for testing effective range) | 5709C-W | — |
Strip back the outer jacket of the wiring cable to let wires flex in the case, and leave slack in the wall to avoid stressing wire connections. Terminal layouts vary by model:
Sensors are omni-directional (360° coverage), measured from the sensor to the farthest point on the glass. Mount as close as 3.3 ft (1 m) from the glass.
Recommended glass size: 1 ft × 2 ft (0.3 m × 0.6 m) or larger.
Glass thickness: Plate 3/32"–1/4"; Tempered 1/8"–1/4"; Wired 1/4"; Laminated 1/8"–1/4".
Avoid installing in: rooms with lined/insulating/sound-deadening drapes, or rooms with closed wooden window shutters inside.
When armed and the sensor trips to an alarm, the LED latches solid for 4 seconds, then reverts to a 1-minute test mode; it then extinguishes (non-latching) or stays latched (latching mode, cleared via the spring clip).
Locate the sensor at least 4 ft from noise sources (TVs, speakers, sinks, doors, etc.) and at least 3.3 ft from the nearest point of the glass to be protected, with a direct line of sight to that glass.
Areas to avoid: glass airlocks/vestibules, kitchens, corner mounting, residential garages, small utility rooms, stairwells, bathrooms, and other small acoustically live rooms. For these locations, use Sentrol shock or ShatterPoint (5600, 5620) sensors on the windows/frames instead.
Coverage geometry: the sensor's optimum detection zone width should be no greater than twice the distance from the sensor to the closest point of glass — e.g., mounted 10 ft from the glass gives a 10-ft optimum zone in either direction from the midpoint.
Note: ShatterPro II may not consistently detect cracks in glass or bullet penetration — always complement with interior protection. It should be connected to a UL-listed control panel or a power supply providing at least 4 hours of standby power.
| Parameter | Value |
|---|---|
| Voltage | 9 to 16 VDC |
| Current | 12 mA typical, 25 mA max |
| Relay output | Normally closed, opens 4 seconds on alarm; On resistance 10Ω (−5/+10); Off resistance >1 MΩ |
| Max loop rating (relay or tamper loop) | 16 VDC, 50 mA |
| Wiring terminals | 22–18 AWG |
| Lightning suppression | 400 watts for a 1 msec pulse |
| RF Immunity | 20 V/m min, 1 MHz–1 GHz |
| Microphone | Omni-directional electret |
| Operating temperature | 0°F to 120°F (−18°C to +50°C) |
| Humidity | 10% to 90%, noncondensing |
Reference: Sentrol/GE Security document G-3513-798, 15651 Rev. A. Technical Service: 800-548-7424.