  • SECO-LARM ENFORCER E-941SA-1K5Q — 1,500-lb Electromagnetic Lock Manual

    September 08, 2026 4 min read

    Complete installation manual for the SECO-LARM ENFORCER E-941SA-1K5Q 1,500-lb Single-Door Electromagnetic Lock.

    Full text manual (for reference)

    Full instruction manual for the SECO-LARM ENFORCER E-941SA-1K5Q 1,500-lb Single-Door Electromagnetic Lock — installation steps, wiring diagram, wire-gauge tables, accessories, and troubleshooting.

    Overview

    The E-941SA-1K5Q is a single-door electromagnetic lock (maglock) that secures a door against unauthorized entry. When power is applied, it generates a strong magnetic field that attracts the steel armature plate mounted on the door. When power is removed, the door releases with no residual magnetism.

    Features

    • Selectable 12/24 VDC operation
    • Anodized aluminum housing
    • No residual magnetism
    • MOV surge protection
    • Keyhole slot mounting plate for easier installation
    • Suitable for horizontal or vertical installation
    • Complete mounting hardware included for typical installations
    • "L", "Z", and "U" brackets and plate spacers available for non-typical mounting situations
    • Detachable faceplate for easy wiring access

    Specifications

    Spec Value
    Holding force 1,500-lb (680kg)
    Operating voltage 12/24 VDC (selectable)
    Current draw 500mA @ 12VDC / 260mA @ 24VDC
    Coil resistance 46Ω ±10% per coil
    Housing material Anodized aluminum
    Operating temperature 14°~131°F (-10°~55°C)
    Mounting plate dimensions 11-1/4"x1-9/16"x1/4" (286x40x6 mm)
    Electromagnet dimensions 11-1/4"x1-9/16"x2-5/8" (286x40x67 mm)
    Armature plate dimensions 7-1/4"x5/8"x2-3/8" (185x16x60 mm)
    Weight 11-lb, 1.2-oz (5kg)

    Parts List

    • 1x Electromagnetic lock, 1x Armature plate, 1x Armature screw
    • 1x 5mm hex wrench, 1x Sexnut bolt, 1x Door spacer
    • 2x Guide pins, 2x Rubber washers, 2x Steel washers
    • 8x Long self-tapping screws, 2x Short self-tapping screws, 1x Mounting plate
    • 1x Mounting template, 1x Manual

    Installation Applications

    Depending on door/frame type and location, additional brackets may be required: "Z" bracket, one or two "L" brackets, "U" bracket (typically for glass doors), and/or plate spacers. Mounting brackets include all additional hardware required.

    Installation Notes

    • For indoor use ONLY.
    • Do not run power wires and signal wires in the same conduit — this may cause interference.
    • Do not install a diode in parallel with the lock — this can cause release delay and residual magnetism.
    • Best location: inside of the secured door, wiring concealed in the frame to prevent tampering.

    Installation Steps

    1. Fold the included mounting template along the dotted center line to form a 90-degree angle.
    2. Close the door and find a mounting location near the upper free-moving corner, opposite the hinges.
    3. Place the template against the door and frame; mark drill hole locations.
    4. Drill two holes in the frame and three holes in the door as marked on the template.
    5. Tap the guide pins into the guide pin holes on the armature plate.
    6. Drill armature-side holes according to door type:
      • Hollow metal door: 5/16" (8mm) hole for armature screw through the armature-plate side; 5/8" (16mm) hole for the sexnut bolt on the opposite side.
      • Reinforced door: 1/4" (6.8mm) hole, 1" (25mm) deep, tapped for M8x1.25 thread.
      • Solid core door: 5/16" (8mm) hole for the armature screw, and 1/2" (12.7mm) hole 1" (25mm) deep for the sexnut bolt.
    7. Mount the armature plate using the sexnut bolt and door spacer with a rubber washer sandwiched between two steel washers, allowing the plate to pivot slightly to compensate for door misalignment.
    8. Tighten the armature screw enough to resist forced entry but loose enough to allow slight pivot; ensure guide pins seat correctly. Tip: use thread-locking compound for a lasting installation.
    9. Remove the anti-tamper screws from the electromagnet and cover plate, then remove the four hex-head mounting screws to detach the mounting plate from the electromagnet.
    10. Install the two short self-tapping screws through the mounting plate's oblong slots (don't fully tighten yet); adjust position by holding the magnet in place, then tighten once aligned.
    11. Install the eight long self-tapping screws once the mounting plate position is confirmed.
    12. Drill the cable access hole and run power leads through the mounting plate and door frame.
    13. Run power leads through the large cable access hole of the electromagnet.
    14. Mount the electromagnet through the keyhole slots, align with the mounting plate, and secure with the hex-head mounting screws.
    15. Cut wires to length for the terminal block. Set the voltage using the selection jumpers to match your input voltage (see Wiring Diagram below). Failure to set the correct voltage may damage the lock.
    16. Connect the power wires per the wiring diagram, test the unit, then replace the cover plate and anti-tamper screws.

    Wiring Diagram Notes

    • 12VDC operation: position two jumpers on all four pins.
    • 24VDC operation: position a single jumper over the two center pins.
    • Connect switching devices (e.g., push-to-exit switches) between the power source and the positive terminal on the lock. Connecting to the negative terminal may cause residual magnetism and a delay in unlocking.

    Minimum Wire Gauge by Distance (12VDC, @500mA)

    Wire Length 25ft 50ft 75ft 100ft 150ft 200ft 250ft 300ft 400ft
    Wire Gauge 20 18 18 18 16 14 14 12 10

    Minimum Wire Gauge by Distance (24VDC, @260mA)

    Wire Length 25ft 100ft 200ft 300ft 500ft 1000ft
    Wire Gauge 24 20 18 16 14 14

    Compatible Accessories

    • E-941S-1K5/LQ — "L" Bracket
    • E-941S-1K5/ZQ — "L" & "Z" Brackets
    • E-941S-1K2/UQ — "U" Brackets
    • E-941S-1K5/PQ — Plate Spacer

    Troubleshooting

    Symptom Checks
    Door does not lock Check terminal block wiring is tight; check power supply is connected/operating; check coil resistance with a multimeter (46Ω ±10%); make sure the rubber washer is installed and undamaged.
    Door locks but can easily be forced open Confirm electromagnet and armature plate alignment; ensure contact surfaces are clean and free from rust; verify 12/24 VDC is present at the leads; check coil resistance; verify rubber washer is intact; check voltage selection jumper settings.
    Delay in door releasing The electromagnet already has a built-in MOV — do not add a second diode; confirm the control device is wired to the positive terminal.

    Checking coil resistance: Remove the faceplate, disconnect the wire harness from the circuit board, and measure resistance across the Red/Green wires and the Black/White wires with a multimeter. Each coil should read 46Ω ±10%. If either coil shows open, short, or incorrect resistance, replace the electromagnet.

    Warranty

    1-year warranty against defects in material and workmanship from the date of sale to the original customer. SECO-LARM's obligation is limited to repair or replacement of defective parts (transportation prepaid to SECO-LARM). Voided by acts of God, misuse/abuse, neglect, unauthorized repair/alteration, improper usage, or faulty installation.