Complete installation manual for the SECO-LARM ENFORCER E-941SA-1K5Q 1,500-lb Single-Door Electromagnetic Lock.
Full instruction manual for the SECO-LARM ENFORCER E-941SA-1K5Q 1,500-lb Single-Door Electromagnetic Lock — installation steps, wiring diagram, wire-gauge tables, accessories, and troubleshooting.
The E-941SA-1K5Q is a single-door electromagnetic lock (maglock) that secures a door against unauthorized entry. When power is applied, it generates a strong magnetic field that attracts the steel armature plate mounted on the door. When power is removed, the door releases with no residual magnetism.
| Spec | Value |
|---|---|
| Holding force | 1,500-lb (680kg) |
| Operating voltage | 12/24 VDC (selectable) |
| Current draw | 500mA @ 12VDC / 260mA @ 24VDC |
| Coil resistance | 46Ω ±10% per coil |
| Housing material | Anodized aluminum |
| Operating temperature | 14°~131°F (-10°~55°C) |
| Mounting plate dimensions | 11-1/4"x1-9/16"x1/4" (286x40x6 mm) |
| Electromagnet dimensions | 11-1/4"x1-9/16"x2-5/8" (286x40x67 mm) |
| Armature plate dimensions | 7-1/4"x5/8"x2-3/8" (185x16x60 mm) |
| Weight | 11-lb, 1.2-oz (5kg) |
Depending on door/frame type and location, additional brackets may be required: "Z" bracket, one or two "L" brackets, "U" bracket (typically for glass doors), and/or plate spacers. Mounting brackets include all additional hardware required.
| Wire Length | 25ft | 50ft | 75ft | 100ft | 150ft | 200ft | 250ft | 300ft | 400ft |
|---|---|---|---|---|---|---|---|---|---|
| Wire Gauge | 20 | 18 | 18 | 18 | 16 | 14 | 14 | 12 | 10 |
| Wire Length | 25ft | 100ft | 200ft | 300ft | 500ft | 1000ft |
|---|---|---|---|---|---|---|
| Wire Gauge | 24 | 20 | 18 | 16 | 14 | 14 |
| Symptom | Checks |
|---|---|
| Door does not lock | Check terminal block wiring is tight; check power supply is connected/operating; check coil resistance with a multimeter (46Ω ±10%); make sure the rubber washer is installed and undamaged. |
| Door locks but can easily be forced open | Confirm electromagnet and armature plate alignment; ensure contact surfaces are clean and free from rust; verify 12/24 VDC is present at the leads; check coil resistance; verify rubber washer is intact; check voltage selection jumper settings. |
| Delay in door releasing | The electromagnet already has a built-in MOV — do not add a second diode; confirm the control device is wired to the positive terminal. |
Checking coil resistance: Remove the faceplate, disconnect the wire harness from the circuit board, and measure resistance across the Red/Green wires and the Black/White wires with a multimeter. Each coil should read 46Ω ±10%. If either coil shows open, short, or incorrect resistance, replace the electromagnet.
1-year warranty against defects in material and workmanship from the date of sale to the original customer. SECO-LARM's obligation is limited to repair or replacement of defective parts (transportation prepaid to SECO-LARM). Voided by acts of God, misuse/abuse, neglect, unauthorized repair/alteration, improper usage, or faulty installation.