September 08, 2026 3 min read
SECO-LARM ENFORCER 80-lb. Electromagnetic Lock (E-941SA-80Q)
Installation manual for the SECO-LARM ENFORCER E-941SA-80Q, an 80-lb. miniature electromagnetic door lock.
When power is applied to the electromagnetic lock, it energizes the unit's built-in electromagnet, which is attracted to the steel armature plate mounted on the door, holding the door fast against unauthorized entry. When power to the lock is turned off, the electromagnet releases the armature plate, allowing the door to open.
| Power | 12–24VDC |
| Magnet Size | 2¾ x 1¼ x 13/16 in. (70 x 31 x 20mm) |
| Armature Size | 2⅛ x 1¼ x 23/64 in. (60 x 31 x 9mm) |
| Holding Force | 80 lb. (36kg) @ 12VDC; 110 lb. (51kg) @ 24VDC |
| Current Drain | 85mA @ 12VDC; 165mA @ 24VDC |
| Voltage Tolerance | ±10% |
| Housing | Aluminum |
| Temperature Range | 14°F to 131°F (-10°C to 55°C) |
| Weight | 0.90 lb. (410g) |
Drilling specifics vary by door type — hollow metal door, solid core door, and reinforced door each require slightly different hole sizes/depths per the mounting template (see installation diagrams for exact 5mm/9mm hole and M5 x 0.8 thread specifications).
Two power wires run from the electromagnet to a control device, then to a 12–24VDC power supply. Red = positive (+); Black = negative (−).
| Problem | Possible Cause | Solution |
|---|---|---|
| Door does not lock | No power | Check wire connections, confirm the power supply is connected and operating, and verify the lock switch is wired correctly. |
| Door locks but can be easily forced open | Poor contact between electromagnet and armature plate | Make sure the electromagnet and armature plate are properly aligned; ensure contact surfaces are clean and rust-free. |
| Insufficient voltage | Check power leads with a meter; ensure power supplied is between 12–24VDC. | |
| Delay in door releasing | A secondary diode was installed across the electromagnet | The electromagnet already has a built-in metal oxide varistor for interference suppression — do not install a secondary diode. |
E-941SA-300RQ (300-lb, weatherproof), E-941SA-300 (300-lb, weatherproof), E-941SA-600 (600-lb), E-941SA-600PQ (600-lb, bond sensor, LED), E-941SA-1200 (1,200-lb), E-941SA-1K2PD (1,200-lb, bond sensor, LED), E-941DA-600 / E-941DA-600PQ (double-door, 600-lb), E-941DA-1K2Q / E-941DA-1K2P / E-941DA-1K2PD (double-door, 1,200-lb, various bond sensor/LED/timer options).
This SECO-LARM product is warranted against defects in material and workmanship for the lifetime of the product in normal service. SECO-LARM's obligation is limited to repair or replacement of defective parts if the unit is returned, transportation prepaid; SECO-LARM is not responsible for removal, installation, or reinstallation costs. The warranty is void if damage is caused by acts of God, misuse, abuse, neglect, unauthorized repair/alteration, improper usage, or faulty installation. This limited warranty is for products sold and installed in the U.S. and Canada; all other countries carry a 1-year warranty.
SECO-LARM® U.S.A., Inc. · 16842 Millikan Avenue, Irvine, CA 92606 · Tel: 800-662-0800 / 949-261-2999 · Fax: 949-261-7326 · www.seco-larm.com · sales@seco-larm.com