  • Qubino Flush Shutter DC (ZMNHOD3) — Installation Instructions

    September 08, 2026 3 min read

    Quick installation instructions for the Qubino Flush Shutter DC (ZMNHOD3): 12-24VDC motor wiring, safety warnings, Z-Wave inclusion/exclusion, and factory reset.

    Full text manual (for reference)

    Quick installation guide for the Qubino Flush Shutter DC (model QUZMNHOD3 and related ZMNHOD-series variants) — ideal for controlling 12–24V DC motors of blinds, rollers, shades, venetian blinds, and similar sunscreens. Can be paired with an optional digital temperature sensor and supports both push-button/momentary switches and toggle switches.

    Package Contents

    • Flush Shutter DC device
    • Installation Manual

    Safety Warnings

    • Danger of electrocution! Installation requires a great degree of skill and may be performed only by a licensed, qualified electrician. Even when the device is off, voltage may still be present in its terminals.
    • Disconnect electrical power at the main fuse or circuit breaker before installation/maintenance. Confirm no voltage remains in the wiring before proceeding.
    • Take extra precautions against accidentally turning the device on during installation. Connect exactly per the wiring diagram.
    • Do not connect to loads exceeding recommended values.
    • When the device is loaded with the maximum rated current of 2A, the output shouldn't be active for more than 60 seconds — overheat protection may activate (all outputs switch off for 60 seconds).
    • For overload protection, use fuse F (ESKA 522.724 5A 250V) connected per the electrical diagram, installed per IEC 60950-1.
    • Place the antenna as far as possible from metal elements; do not shorten the antenna.

    Z-Wave Inclusion (Adding to Network)

    Auto-Inclusion

    1. Enable inclusion mode on your Z-Wave gateway (hub)
    2. Connect the device to the power supply (with the temperature sensor already connected, if used — sold separately)
    3. Auto-inclusion initiates within 5 seconds and the device registers automatically to your network

    Manual Inclusion

    1. Connect the device to the power supply (temperature sensor already connected, if used)
    2. Toggle the I1-terminal switch 3 times within 3 seconds (3 pushes of a push-button, or 6 presses of a toggle switch), or press and hold the S (Service) button for at least 2 seconds
    3. A new multi-level device (motor controller) appears on your dashboard

    Note: Make sure the device is excluded from your network before connecting the temperature sensor. Switch off power, connect the sensor, then re-include the device.

    Z-Wave Exclusion / Reset

    Exclusion

    1. Connect the device to the power supply and ensure it's within range of your gateway or handheld remote
    2. Enable exclusion mode on your gateway
    3. Toggle the I1 switch 3 times within 3 seconds, or press and hold the S (Service) button for 2–6 seconds
    4. The device is excluded, but custom configuration parameters are NOT erased

    Factory Reset

    1. Connect the device to the power supply
    2. Within the first minute, toggle the I1 switch 5 times within 3 seconds, or press and hold the S (Service) button for at least 6 seconds

    Resetting returns all custom parameters to default and deletes the owner ID. Use only when the main gateway/hub is missing or inoperable.

    Key Specifications

    • Controls 12–24V DC motors (H-bridge switching)
    • Supports push-button/momentary switches and toggle switches
    • Z-Wave Repeater: Yes
    • Overload protection via fuse F (ESKA 522.724, 5A 250V) per IEC 60950-1
    • Optional digital temperature sensor input (sold separately)

    Important Notes

    • Do not connect the device to loads exceeding recommended values — improper wiring may be dangerous and result in equipment damage.
    • Max rated current is 2A; continuous output duration is limited to 60 seconds to prevent overheating.
    • Z-Wave wireless communication is not always 100% reliable — do not rely solely on this device where life or valuables depend entirely on its function.