Complete user manual for the Qubino Flush 1 Relay Z-Wave in-wall relay module — installation, wiring, Z-Wave inclusion/exclusion, configuration parameters, and technical specifications.
Complete user manual for the Qubino Flush 1 Relay (model ZMNHAD3 and related ZMNHAD-series variants) — a Z-Wave in-wall relay module that controls on/off for one electrical device, measures its power consumption, and can pair with an optional digital temperature sensor. It installs behind a wall switch, behind a power socket, or in an electrical junction box.
Full illustrated wiring diagrams are in the downloadable PDF. High-level sequence:
For socket installation and temperature sensor installation, the same turn-off-fuse / wire / turn-on-fuse / include sequence applies — see the full PDF for the socket-specific and sensor-specific wiring diagrams.
Overload protection: Electrical installation must be protected by a directly associated overcurrent protection fuse, 10A gG or Time-lag T, rated breaking capacity 1500A (ESKA 522.727), installed in an Adels Contact 503Si/1 DS fuse holder per IEC60669-2-1. Max Power Limit is set automatically by software — if exceeded for more than 5 seconds, the output shuts off until the next restart, and an "Over-load detected" event is sent to the gateway.
Important: Before connecting the temperature sensor, switch off power and make sure the device is excluded from your network first, then reconnect power, connect the sensor, and re-include.
Connect the device to power, ensure it's within range of the gateway, enable add/remove mode, then toggle I1 three times within 5 seconds (or hold the S button 2–6 seconds on 24V SELV power). Custom configuration parameters are NOT erased on exclusion.
Within the first 60 seconds after power-up, toggle the I1 switch 5 times within 5 seconds (or hold the S button for more than 6 seconds on 24V SELV power). This erases all custom parameters and the owner ID — use only when the primary gateway is missing or inoperable.
| Param # | Function | Default / Values |
|---|---|---|
| 1 | In-wall switch type for I1 (controls Q↑ load) | Default 1 (toggle); 0 = push-button |
| 2 / 3 | Input 2 / Input 3 contact type | Default 0 = NO (normally open); 1 = NC |
| 10 | ALL ON / ALL OFF functionality | Default 255 (both active); 0/1/2 disable combinations |
| 11 / 12 | Auto OFF / Auto ON timer for Q↑ load | Default 0 (disabled); 1–32535 seconds/ms |
| 15 | Timer units (seconds vs. milliseconds) | Default 0 = seconds; 1 = milliseconds |
| 30 | Restore on/off status after power failure | Default 0 = restore last state; 1 = always off |
| 40 | Power consumption reporting threshold (%) | Default 10%; 0 = disabled; min 1W change required regardless |
| 42 | Power reporting time interval | Default 0 (disabled); 1–32535 seconds |
| 63 | Q↑ output type — NO/NC when off | Default 0 = NC (0V when off); 1 = NO |
| 100 / 101 | Enable/disable Endpoint I2 / I3, select notification type | 0 = disabled; 1–6 = notification types (motion, CO, CO2, water, heat, smoke); 9 = binary sensor |
| 110 | Temperature sensor offset (Celsius only) | Added/subtracted from measured value |
Full parameter list with all byte sizes and edge cases is in the downloadable PDF.
| Power supply | 110–240 VAC ±10%, 50/60Hz (24–30VDC) |
| Rated load current | 1×10A (240VAC) / 1×10A (30VDC) |
| Output circuit power (resistive) | 2300W (240VAC) / 240W (24VDC) |
| Power measurement accuracy | P=5–50W: ±3W; P>50W: ±3% |
| Digital temperature sensor range | −25 to +80°C (−13 to 176°F), 0.1°C resolution |
| Operating temperature | −10 to +40°C (14 to 104°F) |
| Z-Wave range | Up to 30m (98 ft) indoors |
| Dimensions (WxHxD) | 41.8×36.8×16.9mm (1.65×1.45×0.66 in) |
| Weight | 28g (0.98 oz) |
| Electricity consumption | 0.4W |
| Box requirement | Ø ≥ 60mm (2.36 in) or 2M, depth ≥ 60mm |
| Switching | Relay |
| Z-Wave repeater | Yes |
RC Snubber (for inductive loads, connected in parallel to the load): Capacitance 0.1µF, Voltage 630VDC/275VAC, Resistance 47Ω, Power rating 1/2W. Suggested part: P409CE104M275AH470 (Kemet).
Complies with FCC Part 15 (Class B digital device). Complies with EU Low Voltage Directive (2014/35/EU), EMC Directive (2014/30/EU), Radio Equipment Directive (2014/53/EU), RoHS 2 (2011/65/EU), and ErP Directive (2009/125/EC). Subject to WEEE recycling requirements — do not dispose of as household or commercial waste.
This manual applies to devices with SW version S6 (part of the part number, e.g. ZMNHADxHxS6Px). Manufacturer: Goap d.o.o. Nova Gorica, Ulica Klementa Juga 007, 5250 Solkan, Slovenia. Web: www.qubino.com