    Complete user manual for the Qubino Flush 1 Relay Z-Wave in-wall relay module — installation, wiring, Z-Wave inclusion/exclusion, configuration parameters, and technical specifications.

    Full text manual (for reference)

    Complete user manual for the Qubino Flush 1 Relay (model ZMNHAD3 and related ZMNHAD-series variants) — a Z-Wave in-wall relay module that controls on/off for one electrical device, measures its power consumption, and can pair with an optional digital temperature sensor. It installs behind a wall switch, behind a power socket, or in an electrical junction box.

    Overview

    • Controls ON/OFF for one electrical load and measures its power consumption (W, kWh)
    • Optional external digital temperature sensor input (sold separately, part ZMNHEA1) enables temperature-based scenes
    • Supports push-button (momentary) and standard toggle switches
    • Acts as a Z-Wave repeater to extend network range and stability
    • Two additional inputs (I2, I3) can trigger scenes (e.g., "all lights on" / "all lights off")

    Typical Use Cases

    • Behind a wall switch: lights, ceiling fans, wall-mounted fans, domestic hot water tanks, infrared heaters, and scene-triggering switches
    • Behind a power socket: ovens, irons, fans, floor lamps, microwaves, TVs, computers, and standalone power-consumption monitoring (e.g., refrigerators)
    • In an electrical junction box: 24VDC or 110/240VAC irrigation sprinkler valves, sanitary hot water recirculation pumps, pool recirculation pumps
    • Combined with the optional temperature sensor: temperature-triggered automation scenes for HVAC, pool, or water heating control

    Installation Overview

    Full illustrated wiring diagrams are in the downloadable PDF. High-level sequence:

    1. Turn OFF the fuse. Disconnect power at the main fuse or circuit breaker before installation or maintenance — verify no voltage remains in the wiring before proceeding.
    2. Install the device according to the wiring diagram for your setup: single switch, on/off switch with scene switches, 2+ switches controlling the same light, 2-way switch, multi-way switches, or a switch box with no neutral line.
    3. Position the antenna as upright as possible, away from metal, and do not shorten it — this maximizes range (up to 98 ft / 30 m line of sight).
    4. Turn ON the fuse.
    5. Add the device to your Z-Wave network (see Inclusion below).

    For socket installation and temperature sensor installation, the same turn-off-fuse / wire / turn-on-fuse / include sequence applies — see the full PDF for the socket-specific and sensor-specific wiring diagrams.

    Electrical Diagram Reference (110–240VAC, 24VDC)

    • N — Neutral wire (+VDC)
    • L — Live (line) wire (−VDC)
    • Q↑ — Output for electrical device (load) no. 1
    • I1 — Input for switch/push button
    • I2 / I3 — Inputs for switch/push button or sensor
    • TS — Temperature sensor terminal
    • S — Service button (must NOT be used when connected to 110–240V power supply)
    • Wago 221-413 splicing connectors for L and N connection must be used only when connected to 240VAC

    Overload protection: Electrical installation must be protected by a directly associated overcurrent protection fuse, 10A gG or Time-lag T, rated breaking capacity 1500A (ESKA 522.727), installed in an Adels Contact 503Si/1 DS fuse holder per IEC60669-2-1. Max Power Limit is set automatically by software — if exceeded for more than 5 seconds, the output shuts off until the next restart, and an "Over-load detected" event is sent to the gateway.

    Z-Wave Network — Inclusion / Exclusion / Reset

    Auto Inclusion

    1. Enable add/remove mode on your Z-Wave gateway (hub).
    2. Connect the device to power (with the temperature sensor already connected, if used).
    3. Auto-inclusion starts within 5 seconds and completes within the first 2 minutes of power-up.

    Manual Inclusion

    1. Enable add/remove mode on the gateway.
    2. Connect the device to power.
    3. Toggle the I1 switch 3 times within 5 seconds — OR, if powered by 24V SELV, press and hold the S (Service) button for 2–6 seconds.
    4. A new multi-channel device appears on your dashboard.

    Important: Before connecting the temperature sensor, switch off power and make sure the device is excluded from your network first, then reconnect power, connect the sensor, and re-include.

    Exclusion

    Connect the device to power, ensure it's within range of the gateway, enable add/remove mode, then toggle I1 three times within 5 seconds (or hold the S button 2–6 seconds on 24V SELV power). Custom configuration parameters are NOT erased on exclusion.

    Factory Reset

    Within the first 60 seconds after power-up, toggle the I1 switch 5 times within 5 seconds (or hold the S button for more than 6 seconds on 24V SELV power). This erases all custom parameters and the owner ID — use only when the primary gateway is missing or inoperable.

    Key Configuration Parameters

    Param # Function Default / Values
    1 In-wall switch type for I1 (controls Q↑ load) Default 1 (toggle); 0 = push-button
    2 / 3 Input 2 / Input 3 contact type Default 0 = NO (normally open); 1 = NC
    10 ALL ON / ALL OFF functionality Default 255 (both active); 0/1/2 disable combinations
    11 / 12 Auto OFF / Auto ON timer for Q↑ load Default 0 (disabled); 1–32535 seconds/ms
    15 Timer units (seconds vs. milliseconds) Default 0 = seconds; 1 = milliseconds
    30 Restore on/off status after power failure Default 0 = restore last state; 1 = always off
    40 Power consumption reporting threshold (%) Default 10%; 0 = disabled; min 1W change required regardless
    42 Power reporting time interval Default 0 (disabled); 1–32535 seconds
    63 Q↑ output type — NO/NC when off Default 0 = NC (0V when off); 1 = NO
    100 / 101 Enable/disable Endpoint I2 / I3, select notification type 0 = disabled; 1–6 = notification types (motion, CO, CO2, water, heat, smoke); 9 = binary sensor
    110 Temperature sensor offset (Celsius only) Added/subtracted from measured value

    Full parameter list with all byte sizes and edge cases is in the downloadable PDF.

    Technical Specifications

    Power supply 110–240 VAC ±10%, 50/60Hz (24–30VDC)
    Rated load current 1×10A (240VAC) / 1×10A (30VDC)
    Output circuit power (resistive) 2300W (240VAC) / 240W (24VDC)
    Power measurement accuracy P=5–50W: ±3W; P>50W: ±3%
    Digital temperature sensor range −25 to +80°C (−13 to 176°F), 0.1°C resolution
    Operating temperature −10 to +40°C (14 to 104°F)
    Z-Wave range Up to 30m (98 ft) indoors
    Dimensions (WxHxD) 41.8×36.8×16.9mm (1.65×1.45×0.66 in)
    Weight 28g (0.98 oz)
    Electricity consumption 0.4W
    Box requirement Ø ≥ 60mm (2.36 in) or 2M, depth ≥ 60mm
    Switching Relay
    Z-Wave repeater Yes

    Supported Loads

    • Electric motor: 690W (240VAC) / 330W (110VAC), power factor 0.4 — RC snubber recommended for inductive loads
    • Incandescent / halogen lights: 2300W (240VAC) / 1100W (110VAC)
    • LED bulbs: 320W (240VAC) / 150W (110VAC)
    • CFL / low-voltage halogen with electronic transformer: 800W (240VAC) / 380W (110VAC)

    RC Snubber (for inductive loads, connected in parallel to the load): Capacitance 0.1µF, Voltage 630VDC/275VAC, Resistance 47Ω, Power rating 1/2W. Suggested part: P409CE104M275AH470 (Kemet).

    Package Contents

    • Flush 1 Relay device
    • Installation manual

    Safety Information

    • Read the manual carefully before installing — the manufacturer (GOAP d.o.o. Nova Gorica) is not responsible for damage or injury from incorrect installation or operation outside what's covered in the manual.
    • Check Technical Specifications, Electrical Diagram, and fuse requirements before installing.
    • Z-Wave wireless communication is not always 100% reliable — do not use this device in situations where life or valuables solely depend on its functioning.
    • If the device is not recognized by your gateway or shows up incorrectly, verify your gateway supports multi-channel devices and contact Qubino support before returning the device.

    Regulatory / Compliance

    Complies with FCC Part 15 (Class B digital device). Complies with EU Low Voltage Directive (2014/35/EU), EMC Directive (2014/30/EU), Radio Equipment Directive (2014/53/EU), RoHS 2 (2011/65/EU), and ErP Directive (2009/125/EC). Subject to WEEE recycling requirements — do not dispose of as household or commercial waste.

    This manual applies to devices with SW version S6 (part of the part number, e.g. ZMNHADxHxS6Px). Manufacturer: Goap d.o.o. Nova Gorica, Ulica Klementa Juga 007, 5250 Solkan, Slovenia. Web: www.qubino.com