September 08, 2026 6 min read
Complete user manual for the On-Q/Legrand CM7000 outdoor PoE IP camera, covering installation, configuration, and troubleshooting.
User manual for the On-Q/Legrand CM7000 Outdoor IP Camera — a PoE-powered, weatherproof network camera with motion detection, SIP/VoIP alarm calling, and web-based configuration.
Run Cat 5 cable from an enclosure-mounted PoE (Power over Ethernet) supply device to a single-gang box at the intended camera location (Legrand DA2400 and DA1458 PoE products are suitable). Attach the Cat 5/PoE cable to the camera's cable RJ45 jack and feed the camera cables through the hole in the supplied wallplate; mount the wallplate to the single-gang box using the rubber gasket. Attach the camera to the wallplate with the 3 provided screws and position for use.
| Spec | Value |
|---|---|
| Video Compression | H.264, MJPEG |
| Image Sensor | 1/3", 1.2 Megapixel Progressive Scan CMOS, 1280H x 960V |
| Image Sensor Sensitivity | Day/Night mode; shutter 1/10000 – 1/30 second |
| Focal Length / Aperture | 3.6mm / F1.8 |
| Field Angle (FOV) | 100.2°(D) x 77°(H) x 54°(V) |
| IR Cut Filter | Yes, mechanical |
| Day & Night Mode | IR LED, covering up to 10 meters |
| Minimum Illumination | 0.05 Lux; 0 Lux with IR LED on |
| Max Video Resolution / Frame Rate | 1280x960 (25fps), 1280x720 (30fps) |
| Video Bit Rate | 32 Kbps – 8 Mbps, multi-rate for preview & recording |
| Embedded Analytics | Motion detection, up to 16 target areas |
| Network Protocol | TCP/UDP/IP, RTP/RTCP, RTSP, DHCP, DDNS, HTTP, HTTPS, SMTP, FTP, NTP, UPnP, Bonjour |
| SIP/VoIP Support | Yes |
| Power over Ethernet | IEEE 802.3af, Class 0 |
| External Connections | Network RJ45 10M/100M auto-sensing; 3.5mm audio in/out; power input |
| Dimensions / Weight | 94mm (D) x 230mm (L) / 0.52kg |
| Temperature / Humidity | Operating -20°C~45°C (-4°F~113°F), 10-90% RH non-condensing; Storage -30°C~60°C (-22°F~140°F) |
| Non-PoE Power | 12VDC/1A; input 100–240VAC, 50–60Hz |
| Casing | IP66-compliant weather-proof metal case |
| Compliance | FCC Part 15 Subpart B Class B; EN 55022 Class B; EN 61000-3-2/3-3; EN 55024; EN 60950-1; C-tick AS/NZS CISPR 22/24; IP66 |
The CM7000 is a DHCP client by default and will automatically get an IP address from the network router. The camera can be located via UPnP (PC, Network and Sharing Center) or Bonjour (Mac, Safari's Bonjour list — enable via Safari > Preferences > Advanced if not visible). Alternately, find the assigned IP from the router's DHCP client list or an IP sniffer tool.
If no DHCP server is present or DHCP offer times out (3 minutes), the camera defaults to IP 192.168.1.168.
192.168.1.168/index.html.The home page provides real-size/window-size toggle, brightness/contrast/saturation sliders, language switch (Chinese, English, Russian), play/stop, snapshot capture (default: C:\Capture), record (default: C:\Record), sound on/off, talk, playback, and local configuration (file paths, video delay/smoothness).
Displays and sets the current system time. Time can sync via NTP server, local computer, manual entry, or keep current display time. OSD (on-screen display) date format is selectable. Remember to click Save after changes.
Flip (vertical/horizontal/both), shutter speed (10 options: Auto, 1/30 to 1/10000), IR Cut setting (manual or automatic sensor-controlled), IR Cut sensitivity (5 levels), color mode (Color, Black/White, Auto — Auto recommended for shutter speed, IR LED, IR Cut, and color mode).
IP address via DHCP (default) or static configuration; DNS configuration (automatic or manual); HTTP port (default 80).
Enable DDNS, select ISP type from the pull-down list (or self-define the DDNS address), configure site name, account, and password. A STUN server can help penetrate non-symmetric router NAT.
The CM7000 can register as a SIP endpoint to call out when an alarm triggers, or allow permitted numbers to call in and check the video.
| Setting | Description |
|---|---|
| Registered | SIP registration status — "Online" (green) or "Offline" (red) |
| Unregister on Reboot | Unbinds all registrations on reboot if checked |
| SIP Server / Outbound Proxy | FQDN or IP of SIP server / NAT-penetrating outbound proxy |
| Registration Expiration | Default 3600 seconds |
| Local SIP / RTP Ports | Default 5060 / 5004 |
| Auto On-hook Timer | Default 300 seconds |
| Phone List / White List | Numbers to call on alarm / numbers allowed to call in |
Add or revise users, set passwords, choose privilege level. "Allow Anonymous Viewing" permits any viewer who knows the camera's IP/FQDN to view (but not change) settings.
Enable SMTP, set server/port, from/to email addresses (up to 3 recipients), credentials, SSL, and customizable subject/body. Use "Test" to confirm the configuration sends successfully.
Enable FTP client, set server/port (default 21), credentials, and upload path. "Test" verifies the connection.
Configure a server name, URL, and credentials for uploading alarm events to a supported VMS or third-party HTTP server via the GS HTTP API.
Enable and set a trigger interval for automatic snapshots, with optional FTP and/or SMTP upload.
16 configurable alarm regions (0–15), each with adjustable sensitivity (up to 100, max sensitivity). Alarm actions include: pre/post-alarm video recording duration, SIP voice alarm call, upload to Alarm Center or Alarm HTTP Server, record-and-upload via FTP, and email/FTP JPEG snapshot upload. A schedule can define start/stop times per region for when motion detection is active.
Configure a syslog server IP/domain and log level (None, Debug, Info, Warning, Error) for troubleshooting.
| Question | Answer |
|---|---|
| Default IP address? | DHCP by default (192.168.1.168 as fallback static) |
| Can't view live video in Internet Explorer? | Install the IE add-on when prompted after logging into the web interface. |
| Can't access the web configuration interface? | Check internet connectivity, subnet/gateway match between camera and PC, IP address conflicts, and whether the HTTP port was changed. |
| Config page not displaying correctly in IE8? | Enable Compatibility View in IE8 for the camera's config pages. |
| IE asks to reinstall the video viewer add-on after firmware upgrade? | New firmware often upgrades the add-on too — install the newest version to keep watching the live stream. |
| How to watch the secondary stream? | Right-click the video on the home page and select "Secondary Stream" from the pop-up menu. |
| Why is there no audio in recorded alarm video? | To meet the IP66 outdoor rating, the CM7000 has no microphone installed, though the PCB has the interface. |
| What is DDNS and why does it matter? | Dynamic Domain Name Service keeps a hostname pointed at the camera's current (possibly changing) IP address — important on networks with dynamic IPs. |
| Windows Media Player won't play recorded video? | Install the Microsoft FFDShow H.264 decoder (available from SourceForge). |
| Watching from a cell phone? | Set video resolution to QCIF and bit rate to 64kbps for best results on a phone. |
| Port forwarding for remote access? | Forward both the HTTP (web) port and the RTSP port. If the web port is 80, RTSP is 554; otherwise RTSP = web port + 2000 (e.g. web port 88 → RTSP 2088). |
Manufacturer: Legrand, 301 Fulling Mill Road, Suite G, Middletown, PA 17057. Phone (800) 321-2343, www.legrand.us. Document 1308235 Rev. B, © 2014.