  • On-Q/Legrand CM7000 — Outdoor IP Camera User Manual

    September 08, 2026 6 min read

    Complete user manual for the On-Q/Legrand CM7000 outdoor PoE IP camera, covering installation, configuration, and troubleshooting.

    Full text manual (for reference)

    User manual for the On-Q/Legrand CM7000 Outdoor IP Camera — a PoE-powered, weatherproof network camera with motion detection, SIP/VoIP alarm calling, and web-based configuration.

    Safety & Regulatory Notes

    • Complies with FCC Part 15, Class B — this device may not cause harmful interference and must accept any interference received.
    • Do not expose to rain, moisture, dripping, or splashing water — risk of fire or shock.
    • Do not open the unit or perform servicing beyond what's described in the installation/troubleshooting instructions — refer all servicing to qualified personnel.
    • Postpone installation during thunderstorms or lightning activity; an AC surge protector on the outlet is recommended.
    • Wipe with a clean, dry cloth only — never use cleaning fluid, chemicals, sprayed cleaners, or forced air.
    • Keep away from excessive heat, humidity, vibration, and dust. Installation must follow national wiring codes and local regulations.

    Equipment Package Contents

    • CM7000 IP Camera
    • Wall plate
    • Installation sheet

    Installing the CM7000

    Run Cat 5 cable from an enclosure-mounted PoE (Power over Ethernet) supply device to a single-gang box at the intended camera location (Legrand DA2400 and DA1458 PoE products are suitable). Attach the Cat 5/PoE cable to the camera's cable RJ45 jack and feed the camera cables through the hole in the supplied wallplate; mount the wallplate to the single-gang box using the rubber gasket. Attach the camera to the wallplate with the 3 provided screws and position for use.

    Specifications

    Spec Value
    Video Compression H.264, MJPEG
    Image Sensor 1/3", 1.2 Megapixel Progressive Scan CMOS, 1280H x 960V
    Image Sensor Sensitivity Day/Night mode; shutter 1/10000 – 1/30 second
    Focal Length / Aperture 3.6mm / F1.8
    Field Angle (FOV) 100.2°(D) x 77°(H) x 54°(V)
    IR Cut Filter Yes, mechanical
    Day & Night Mode IR LED, covering up to 10 meters
    Minimum Illumination 0.05 Lux; 0 Lux with IR LED on
    Max Video Resolution / Frame Rate 1280x960 (25fps), 1280x720 (30fps)
    Video Bit Rate 32 Kbps – 8 Mbps, multi-rate for preview & recording
    Embedded Analytics Motion detection, up to 16 target areas
    Network Protocol TCP/UDP/IP, RTP/RTCP, RTSP, DHCP, DDNS, HTTP, HTTPS, SMTP, FTP, NTP, UPnP, Bonjour
    SIP/VoIP Support Yes
    Power over Ethernet IEEE 802.3af, Class 0
    External Connections Network RJ45 10M/100M auto-sensing; 3.5mm audio in/out; power input
    Dimensions / Weight 94mm (D) x 230mm (L) / 0.52kg
    Temperature / Humidity Operating -20°C~45°C (-4°F~113°F), 10-90% RH non-condensing; Storage -30°C~60°C (-22°F~140°F)
    Non-PoE Power 12VDC/1A; input 100–240VAC, 50–60Hz
    Casing IP66-compliant weather-proof metal case
    Compliance FCC Part 15 Subpart B Class B; EN 55022 Class B; EN 61000-3-2/3-3; EN 55024; EN 60950-1; C-tick AS/NZS CISPR 22/24; IP66

    Minimum Recommended Computer System

    • Windows 2000, XP, Vista, or 7 (32-bit or 64-bit)
    • Intel Pentium 4 or higher, 2 GHz
    • 1 GB RAM (4 GB recommended for larger systems)
    • DirectX 8.0 or above

    Connecting to the Camera

    DHCP (Recommended)

    The CM7000 is a DHCP client by default and will automatically get an IP address from the network router. The camera can be located via UPnP (PC, Network and Sharing Center) or Bonjour (Mac, Safari's Bonjour list — enable via Safari > Preferences > Advanced if not visible). Alternately, find the assigned IP from the router's DHCP client list or an IP sniffer tool.

    Static IP

    If no DHCP server is present or DHCP offer times out (3 minutes), the camera defaults to IP 192.168.1.168.

    1. Connect the computer directly to the camera via Ethernet cable.
    2. Set the computer's IP to Static 192.168.1.XXX (1<XXX<255, not 168), subnet mask 255.255.255.0, gateway blank.
    3. Power on the CM7000 and open the browser (IE or Firefox).
    4. Navigate to 192.168.1.168/index.html.
    5. Install the plug-in/ActiveX prompt if shown, then the home page displays live video (anonymous access is enabled by default).
    6. Click the "Configuration" icon (tools icon, lower-left) and log in with the default admin username/password (both admin).

    Home Web Page Controls

    The home page provides real-size/window-size toggle, brightness/contrast/saturation sliders, language switch (Chinese, English, Russian), play/stop, snapshot capture (default: C:\Capture), record (default: C:\Record), sound on/off, talk, playback, and local configuration (file paths, video delay/smoothness).

    Basic Settings

    System Settings

    Displays and sets the current system time. Time can sync via NTP server, local computer, manual entry, or keep current display time. OSD (on-screen display) date format is selectable. Remember to click Save after changes.

    Video & Audio Settings

    • OSD: time stamp and identifying text on the video screen; position top or bottom.
    • Primary/Secondary Stream: preferred codec (H.264 recommended; MJPEG used automatically for remote smartphone viewing), profile, resolution, bit rate, max frame rate, bit rate control (constant/variable), image quality, I-frame interval.
    • Audio: preferred codec (PCMU, PCMA, AAC), microphone/speaker volume, light condition (select local power frequency to avoid flicker under fluorescent light — default Outdoor).
    • Tip: if MJPEG is selected, reduce max frame rate to save bandwidth and improve image quality.

    CMOS Settings

    Flip (vertical/horizontal/both), shutter speed (10 options: Auto, 1/30 to 1/10000), IR Cut setting (manual or automatic sensor-controlled), IR Cut sensitivity (5 levels), color mode (Color, Black/White, Auto — Auto recommended for shutter speed, IR LED, IR Cut, and color mode).

    Networking Settings

    IP address via DHCP (default) or static configuration; DNS configuration (automatic or manual); HTTP port (default 80).

    • If behind a router with port forwarding, use a static IP to avoid address changes after router reboot.
    • TCP ports above 5000 are suggested for HTTP port forwarding, since some ISPs block inbound port 80 (e.g. change HTTP to 8088).
    • An RTSP port is also needed for remote H.264 viewing: RTSP port = 2000 + HTTP port. Example: HTTP 8088 → RTSP 10088. Both ports must be forwarded in the router.

    DDNS Settings

    Enable DDNS, select ISP type from the pull-down list (or self-define the DDNS address), configure site name, account, and password. A STUN server can help penetrate non-symmetric router NAT.

    SIP Settings (Alarm Calling)

    The CM7000 can register as a SIP endpoint to call out when an alarm triggers, or allow permitted numbers to call in and check the video.

    Setting Description
    Registered SIP registration status — "Online" (green) or "Offline" (red)
    Unregister on Reboot Unbinds all registrations on reboot if checked
    SIP Server / Outbound Proxy FQDN or IP of SIP server / NAT-penetrating outbound proxy
    Registration Expiration Default 3600 seconds
    Local SIP / RTP Ports Default 5060 / 5004
    Auto On-hook Timer Default 300 seconds
    Phone List / White List Numbers to call on alarm / numbers allowed to call in

    Advanced Settings

    User Management

    Add or revise users, set passwords, choose privilege level. "Allow Anonymous Viewing" permits any viewer who knows the camera's IP/FQDN to view (but not change) settings.

    Maintenance

    • Restart: reboots the camera.
    • Restore: resets to factory default, wiping configuration except IP address.
    • Firmware/Config upgrade: via TFTP, HTTP, or HTTPS; server paths and XML config password can be set; automatic upgrade interval default 10080 minutes.

    SMTP Settings (Email Alarm)

    Enable SMTP, set server/port, from/to email addresses (up to 3 recipients), credentials, SSL, and customizable subject/body. Use "Test" to confirm the configuration sends successfully.

    FTP Settings (Upload Alarm)

    Enable FTP client, set server/port (default 21), credentials, and upload path. "Test" verifies the connection.

    Alarm Server Settings (VMS/HTTP)

    Configure a server name, URL, and credentials for uploading alarm events to a supported VMS or third-party HTTP server via the GS HTTP API.

    Periodic Snapshot

    Enable and set a trigger interval for automatic snapshots, with optional FTP and/or SMTP upload.

    Motion Detection

    16 configurable alarm regions (0–15), each with adjustable sensitivity (up to 100, max sensitivity). Alarm actions include: pre/post-alarm video recording duration, SIP voice alarm call, upload to Alarm Center or Alarm HTTP Server, record-and-upload via FTP, and email/FTP JPEG snapshot upload. A schedule can define start/stop times per region for when motion detection is active.

    Syslog Settings

    Configure a syslog server IP/domain and log level (None, Debug, Info, Warning, Error) for troubleshooting.

    Frequently Asked Questions

    Question Answer
    Default IP address? DHCP by default (192.168.1.168 as fallback static)
    Can't view live video in Internet Explorer? Install the IE add-on when prompted after logging into the web interface.
    Can't access the web configuration interface? Check internet connectivity, subnet/gateway match between camera and PC, IP address conflicts, and whether the HTTP port was changed.
    Config page not displaying correctly in IE8? Enable Compatibility View in IE8 for the camera's config pages.
    IE asks to reinstall the video viewer add-on after firmware upgrade? New firmware often upgrades the add-on too — install the newest version to keep watching the live stream.
    How to watch the secondary stream? Right-click the video on the home page and select "Secondary Stream" from the pop-up menu.
    Why is there no audio in recorded alarm video? To meet the IP66 outdoor rating, the CM7000 has no microphone installed, though the PCB has the interface.
    What is DDNS and why does it matter? Dynamic Domain Name Service keeps a hostname pointed at the camera's current (possibly changing) IP address — important on networks with dynamic IPs.
    Windows Media Player won't play recorded video? Install the Microsoft FFDShow H.264 decoder (available from SourceForge).
    Watching from a cell phone? Set video resolution to QCIF and bit rate to 64kbps for best results on a phone.
    Port forwarding for remote access? Forward both the HTTP (web) port and the RTSP port. If the web port is 80, RTSP is 554; otherwise RTSP = web port + 2000 (e.g. web port 88 → RTSP 2088).

    Manufacturer: Legrand, 301 Fulling Mill Road, Suite G, Middletown, PA 17057. Phone (800) 321-2343, www.legrand.us. Document 1308235 Rev. B, © 2014.