September 08, 2026 6 min read
User guide for the Broan-NuTone PurePower Series central vacuum power units (PP500, PP600, PP650) — safety, filter maintenance, service parts, and troubleshooting.
User guide for the Broan-NuTone PurePower Series Central Vacuum Power Units — Models PP500, PP600, and PP650. Covers safety instructions, grounding, filter maintenance, service parts, and troubleshooting for residential central vacuum systems.
For residential use only. When using an electrical appliance, follow these precautions to reduce the risk of fire, electric shock, or injury:
This appliance must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. The appliance is equipped with a cord having an equipment-grounding conductor and grounding plug, which must be plugged into an appropriate outlet properly installed and grounded in accordance with local codes.
This appliance is for use on a standard 120 VAC, minimum dedicated 20-amp branch circuit with a NEMA 5-15R receptacle. No adapter should be used with this power unit. Inlet leads are connected to the power unit's low voltage tabs using crimp connectors (included in the parts bag) and low voltage harness.
Open the inlet cover and insert the end of the hose into the inlet to turn on the vacuum. For non-switched hoses, inserting the hose automatically turns on the power unit; removing it shuts the unit off. Some hoses have switches to activate the power unit. Unless using the utility valve (PP650 only), keep the ON/OFF switch on the power unit in the OFF position. Avoid picking up very large or lengthy debris, as it may become lodged in the hose or tubing.
With a 6 U.S. gallon capacity, under normal conditions the bag/debris pail requires changing/emptying approximately twice a year. Reduced suction usually means the bag/pail is full. Even if not filled to capacity, if the bag seems tightly stretched when removing the debris pail, change it to prevent tearing.
Release both latches on the sides of the unit by pulling out then pushing up. Holding the pail by the latches, lower it from the unit, carry it to a trash receptacle, and dispose of the debris. Put the pail back in place.
Release both latches, remove the pail, then grasp the edges of the bag collar and pull down — the bag will slide off easily (do not pull on the bag itself). Unfold the new bag, grasp the collar where indicated, and insert it over the bag adapter, being careful not to tear it. Ensure the collar sits between the taper ring and bag stopper on the bag adapter.
This filter protects the motor and stops small particles from escaping without needing replacement. It cleans itself by moving up when the unit starts and dropping down when turned off. Under normal use there's no need to maintain it, but it can be removed to inspect the foam motor filter or replaced if damaged.
Caution: Reinstall the filter properly — correct location is critical for motor protection.
A foam motor safety filter at the top of the vacuum chamber protects against dirt being pulled into the motor if the disposable bag or sealed HEPA filter is torn. Check and clean when replacing the bag or removing the HEPA filter. Brush it clean, or hand wash in mild detergent solution if excessively soiled, rinse, and let dry completely before reinstalling.
Caution: Operating the power unit without the foam motor filter will void the warranty.
To remove: take out the debris pail and disposable bag or permanent filter, lift the center of the wire retaining the foam motor filter, and slide the filter out. Reverse to reinstall.
This is a disposable HEPA filter — do not attempt to wash it, as this will damage it. Replace every 5 years.
| Key No. | Part No. | Description | PP500 / PP600 / PP650 |
|---|---|---|---|
| 1 | S10941409 / S10941424 / S10941411 | Top Cap Assembly (upper part, PP650 includes item 5) | 1 each model |
| 2 | S10941416 | PP650 Exhaust HEPA Filter | PP650 only |
| 3 | S10941413 | PP650 Top Cap Assembly (lower part, incl. item 5) | PP650 only |
| 4 | S10941399 | Motor Foam Filter with Fastener | All units |
| 5 | S10941400 | Gasket | All units |
| 6 | S10941415 | Sealed HEPA Permanent Filter | PP600 / PP650 |
| 7 | S99670648 | Debris Pail (incl. latch) | All units |
| 8 | S10941199 | Latch and Screws (x2) | All units |
| 9 | S10941404 | Latch Keeper with Screws (x2) | All units |
| 10 | S10941405 | Bag Adapter with Nut and Screw | All units |
| 11 | S10941408 | Utility Valve | PP650 only |
| 12 | S10941406 | Intake Elbow with Gasket, Screws, Nuts | All units |
| 13 | S30390555 | Unit Support Bracket | All units |
| 14 | 391 | Disposable Bag (set of 3) | All units |
Order service parts by "Part No." — not by "Key No."
| Problem | Possible Cause | Possible Remedy |
|---|---|---|
| Loss/decrease of suction | Debris pail or disposable bag full; damaged/missing pail gasket | Change bag/empty pail; replace pail gasket |
| Loss/decrease of suction | Obstruction in hose or tubing system inside walls | Locate blockage by checking suction at each inlet; clear with a flexible garden hose or by repeatedly covering/uncovering the hose end; contact Service Center if unresolved |
| Loss/decrease of suction | Sealed HEPA filter or disposable bag torn; wall inlet cover not sealed; exhaust tubing/vent clogged | Clean interior and install new filter/bag; check inlet covers; inspect and remove blockages |
| Power unit does not start or stops suddenly | Defective inlet; internal circuit breaker activated (reset button popped up) | Replace defective wall inlet; push the RESET button on the left side of the power unit; contact Service Center if it pops up again |
| Power unit does not start or stops suddenly | Blown house fuse/tripped breaker; defective hose; overcurrent protector activated | Replace fuse/reset house breaker; replace hose; unplug 15+ minutes and plug back in |
| Power unit runs continuously when hose removed | Unit power switch in ON position; electrical short in the system | Set power switch to OFF; check all wall inlets and low voltage control leads, contact Service Center |
NuTone warrants its central vacuum power unit to the original consumer purchaser against defects in materials and workmanship for 5 years (PP500), 8 years (PP600), and 10 years (PP650). The first year covers parts and labor at an authorized service center; after the first year, parts only are covered. This warranty does not apply to installation or the installed tubing system. Hoses, brushes, filters, attachments, and accessories are warranted for 1 year (excluding consumables like light bulbs and belts). Register your product at www.nutone.com/register.
For assistance: 1-888-336-3948 (contiguous US) | www.nutone.com