  • NuTone Overture Room Sensor (BIAQRS100) — Installation Instructions

    September 08, 2026 3 min read

    Installation instructions for the Broan-NuTone Overture Room Sensor, a Wi-Fi indoor air quality sensor for the Overture smart ventilation system.

    Full text manual (for reference)

    Installation instructions for the Broan-NuTone Overture™ Room Sensor (Part No. 1103435) — a Wi-Fi indoor air quality and environment sensor that connects to the Broan-NuTone Overture™ smart ventilation system.

    What's Included

    • Room Sensor, Part No. 1103435
    • User Manual
    • Quick Start Guide

    Control Specifications

    • cULus Listed
    • 120 VAC, 60 Hz line power; requires a NEMA 5-15R or 5-20R receptacle
    • Maximum load: ½ HP motor, 15A resistive, 15A inductive, 3A incandescent, 0.6A electronic ballast
    • For control of electronic ballasts, CFLs, LED, and LED lamps
    • Operating temperature: 32–95°F (0–35°C)
    • Purpose of control: Operating Control
    • Rated impulse voltage: 1500V

    Installation Steps

    1. Verify Room Sensor orientation before installation — note the "TOP" direction printed on the sensor's label.
    2. Choose a good location:
      • Avoid placing directly above a heater or near drafts.
      • Ideal spots: bedrooms, family/living rooms, dens, laundry rooms — anywhere with adequate airflow. Placing the sensor directly behind a dresser, couch, etc. will block adequate airflow and hurt monitoring accuracy.
      • For bathrooms, place it close to the shower/tub/sink (the main humidity/steam/VOC source), at sink height or higher, for effective air-quality monitoring.
      • Keep the sensor within about 100 feet of your Wi-Fi router or access point.
      • Avoid physical obstructions and radio interference in the surrounding area.
    3. Download the Broan-NuTone Overture™ App and follow the step-by-step setup instructions to connect the Room Sensor to your Overture™ system (scan the QR code on the unit/packaging to go to the App Store).

    Safety Notes

    • Install only in a UL-listed NEMA 5-15R or 5-20R receptacle, located near the equipment and easily accessible. Do not use a wall-switch-controlled receptacle.
    • The automatic operation feature is Type 1.C action per UL 60730-1. Enclosure protection rating is IP10. The product is rated Pollution Degree 2 (intended for household/similar environments).
    • Not intended for locations where temperature may be lower than normal room conditions, such as unheated warehouses or garages.
    • Keep away from water, fire, excessive humidity, or hot environments; avoid wet locations.
    • Do not use where wireless devices are prohibited.
    • For passthrough/power-strip setups, plug strips into the device's integrated sockets — do not stack devices of the same or different type in normal use.
    • Do not disassemble, repair, or modify the device — this risks electric shock and voids the limited warranty. Contact support for service.
    • When power is first applied, allow about 30 seconds for the Room Sensor to boot up before it's ready to function.

    Regulatory Information

    FCC ID: 2ADLL-1103435  |  IC: 2143B-1103435

    This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: (1) it may not cause harmful interference, and (2) it must accept any interference received, including interference that may cause undesired operation. Minimum distance between user and device: 20 cm. This equipment has been tested and found to comply with Class B digital device limits, providing reasonable protection against interference in a residential installation, though interference in a particular installation is not guaranteed against. If interference to radio/TV reception occurs, try reorienting/relocating the receiving antenna, increasing separation between the equipment and receiver, connecting the equipment to a different circuit, or consulting the dealer/an experienced technician.

    Contains license-exempt transmitter(s)/receiver(s) complying with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to: (1) the device may not cause interference, and (2) the device must accept any interference, including interference that may cause undesired operation.

    Made in China to the quality standards and specifications of Broan-NuTone LLC. Uses the Bluetooth® word mark and logo under license from Bluetooth SIG, Inc. Includes the Android robot, reproduced/modified from work created and shared by Google under the Creative Commons 3.0 Attribution License.

    Support & Warranty

    For warranty statements, service parts, technical support, or to register your product:

    • United States: Broan-NuTone.com  |  800-558-1711
    • Canada: Broan.ca or NuTone.ca  |  877-896-1119

    Broan-NuTone LLC, Hartford, Wisconsin  |  Venmar Ventilation ULC, Drummondville, Quebec, Canada