Quick start installation guide for Linear's HAF Reader family (NBT125, BT125, BT135) — BLE mobile / 125 kHz / 13.56 MHz access control readers.
Quick start installation guide for Linear's BLE Mobile / 125 kHz / 13.56 MHz Access Control Readers (HAF Reader family — models NBT125, BT125, BT135).
The Linear Access Control reader combines RFID and Bluetooth technology, reading data from physical and/or mobile credentials via radio frequency and passing it to a physical access control system for managing and recording movement through a protected area (e.g., a locked door). This guide is intended for experienced installing technicians and covers wiring, cable requirements, and troubleshooting. For more information, see Linear's website (www.linear-solutions.com).
Each reader can be installed indoors or outdoors, mullion-mount or single-gang mount. Installation and wiring must comply with National Electrical Code (ANSI/NFPA 70). Use the supplied #6 mounting screws or equivalent security screws.
| Conductor | Function |
|---|---|
| Red | DC (8–14 VDC) |
| Black | Ground |
| Green | Data 0 |
| White | Data 1 |
| Brown | Red LED (single-line LED mode) |
| Orange | Not used |
| Yellow | Not used |
| Blue | Beeper |
| Violet | CSN Mode (BT135 only) |
| Drain | Shield ground |
Single-line LED mode (standard, does not use the Orange conductor): idle LED is Red on NBT125, Blue on BT125/BT135; flashes when a card is presented. On all models, the LED turns green when the Brown conductor is pulled low by the access control panel.
Sector vs. CSN mode (BT135 only): standard operation outputs only Sector data (Purple/Violet conductor unused). Pulling the Violet conductor low (grounded) switches the reader to output the smart card's CSN data instead.
Unused conductors should be trimmed, isolated, and taped back to prevent unintended current flow. Apply positive voltage only to the Red DC conductor.
Wiegand (industry-standard 26-bit and custom Wiegand formats): NBT125-W, BT125-W, BT135-W.
Shield (drain) continuity must run from the reader to the access panel. Shield/drain and reader ground must be tied together at the access panel and connected to earth ground at one single point.
The reader may be powered by the access panel; a Linear power supply is recommended for best operation. Connection must comply with NFPA 70 — do not connect to a switch-controlled receptacle; use a power-limited DC voltage source.
| Model | Voltage / Current |
|---|---|
| NBT125 | 8–14 VDC, 80mA |
| BT125 | 8–14 VDC, 60mA typical / 120mA peak |
| BT135 | 8–14 VDC, 60mA typical / 250mA peak |
On power-up, the reader beeps 4 times and the LED shines red or blue. Presenting a supported credential makes the reader beep and flash the LED once (the access panel controls further LED behavior, such as switching to green).
| Possible Cause | Corrective Action |
|---|---|
| Incorrect cabling | Verify gauge, connections, and cable length |
| Not enough power | 12 VDC recommended |
| Incorrect card used | Verify the card technology is supported |
| Reader/panel not properly grounded | Verify shield and reader ground are tied at the access panel and connected to earth ground at one point |
| Supply generating interference | Use a Linear power supply; verify against switching power supplies before use |
If corrective actions don't help, disconnect the reader from the access panel and power it separately (a separate supply or 9V battery) to isolate variables, then re-test. If the problem persists, contact Linear directly.
Complies with Part 15 of the FCC rules and applicable Innovation, Science and Economic Development Canada license-exempt RSS standards. Tested and found to comply with Class A digital device limits per FCC Part 15 for commercial environments — operation in a residential area may cause interference that the user must correct at their own expense.
Certifications include Destructive Level I, Line Security Level I, Endurance Level IV, Standby Power Level I. Operating temperature: -31°F to +150°F (-35°C to +66°C). Operating humidity: 0–90% RH. IP Rating: IP67.