0

Your Cart is Empty

  • Add description, images, menus and links to your mega menu

  • A column with no settings can be used as a spacer

  • Link to your collections, sales and even external links

  • Add up to five columns

  • Leviton ODC Series Occupancy Sensors — Product Sell Sheet

    September 08, 2026 3 min read

    Product overview of the Leviton ODC Series Occupancy Sensors — self-contained energy management combining occupancy sensing, daylight harvesting, and override control.

    Full text manual (for reference)

    Product sell sheet for the Leviton ODC Series Occupancy Sensors — a self-contained energy management solution combining occupancy sensing, daylight harvesting, and manual-ON/auto-OFF override control in a single unit.

    Overview

    The ODC Series simplifies energy management with an easy-to-install self-contained solution: it integrates line-voltage occupancy sensing and photocell technology into one unit, eliminating separate power packs and occupancy sensor wiring for savings in labor, time, and material — while providing additional energy savings with true daylight harvesting.

    Key Design Elements

    • Daylight harvesting with integrated photocell — includes angled light pipe for open loop and flat light pipe for closed loop applications, with auto-calibration
    • Mechanically held 10A latching relay for robust, reliable performance
    • BMS input / emergency override
    • Industry-exclusive fail-safe circuitry
    • Industry-exclusive High Inrush Stability (H.I.S.) circuitry
    • Output short circuit protection
    • LED status indicators

    Passed stringent testing: tested to exceed 1 million switching cycles, passed rigorous NEMA410 testing for electronic ballast rating, and multiple compliance/regulatory UL testing.

    Competitive Comparison

    Feature ODC Series Typical Competition
    Integrated Occupancy Sensor, Power Pack, and Photocell Technology in Self-Contained Unit Yes Purchase occupancy sensor, power pack, and photocell separately
    Daylight Harvesting – Closed Loop and Open Loop Yes Purchase photocell separately
    Includes Angled Light Pipe and Flat Light Pipe Yes Purchase multiple photocells separately
    Automatic Daylight Calibration Yes Purchase photocell separately
    Includes Multiple Lenses for Multiple Applications Mid-range, high density, and extended range lenses on select models Purchase multiple occupancy sensors separately
    Momentary/Maintained Switch Leviton-exclusive self-detect configurable local switch input
    Fail-Safe Circuit Leviton-exclusive feature

    Features

    • Self-contained unit combining occupancy sensor technology with integrated photocell
    • Daylight harvesting capabilities — occupancy sensor models include an angled light pipe and flat light pipe for open loop and closed loop applications; auto-calibration intelligently measures light levels to determine optimal daylight design levels for closed loop applications
    • Output short circuit protection
    • BMS input / emergency override
    • Industry-exclusive self-configuring local manual switch input supports momentary and maintained switches
    • Industry-exclusive "fail-safe" circuitry assures lights ON to meet life safety requirements
    • Industry-exclusive High Inrush Stability (H.I.S.) technology for unmatched durability and service life
    • Mechanically held 10A latching relay provides dependability and robust performance for all load types
    • Zero-crossing circuitry for extended relay life
    • Simplified commissioning; visual LED status indicators
    • Mid-range, high density, and extended range lenses are easily replaceable
    • Easy installation into junction boxes with Leviton-exclusive screw guides, coasters, and terminal blocks
    • CA Title 20 Compliant, UL773A (Occupancy Standard), UL924 (Emergency Equipment), cUL Listed, CE Compliant, NOM Certified, RoHS Compliant

    Installation

    Conveniently mounts to a standard 4" x 4" square or octagon electrical box. Wire terminals allow for simple connection to a line-voltage circuit. The system supports local switching & override control using standard electrical switches — no special control stations required.

    Wiring: Line, Neutral, and Load connections at 120–277VAC, 50/60Hz. Local manual switch (MAN SW) and emergency override (EMER. INPUT) terminals connect to a 12VDC Class 1 or 2 (SELV) circuit for manual switch and emergency interface input.

    Ordering Information

    Cat. No. Description
    ODC04-IDW Passive Infrared Ceiling Mount Occupancy Sensor w/Integrated Photocell, 450SF, 120-277V
    ODC15-IDW Passive Infrared Ceiling Mount Occupancy Sensor w/Integrated Photocell, 1500SF, 120-277V
    ODC05-UDW Ultrasonic Ceiling Mount Occupancy Sensor w/Integrated Photocell, 500SF, 120-277V
    ODC10-UDW Ultrasonic Ceiling Mount Occupancy Sensor w/Integrated Photocell, 1000SF, 120-277V
    ODC20-UDW Ultrasonic Ceiling Mount Occupancy Sensor w/Integrated Photocell, 2000SF, 120-277V
    ODC05-MDW Multi-Technology Ceiling Mount Occupancy Sensor w/Integrated Photocell, 500SF, 120-277V
    ODC10-MDW Multi-Technology Ceiling Mount Occupancy Sensor w/Integrated Photocell, 1000SF, 120-277V
    ODC20-MDW Multi-Technology Ceiling Mount Occupancy Sensor w/Integrated Photocell, 2000SF, 120-277V
    O3C15-IDW Passive Infrared Ceiling Mount Vacancy Sensor, 1500SF, 120-277V
    O3C10-MDW Multi-Technology Ceiling Mount Vacancy Sensor, 1000SF, 120-277V
    O3C20-MDW Multi-Technology Ceiling Mount Vacancy Sensor, 2000SF, 120-277V

    Company Information

    Leviton Manufacturing Co., Inc. Lighting & Energy Solutions • 201 N. Service Rd. Melville, NY 11747-3138 • Tech Line: 1-800-824-3005 • Fax: 1-800-832-9538 • www.leviton.com/les

    © 2013 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.