    Installation manual for Leviton's Single and Dual Mount Back-to-Back Pedestal (EPED1, EPED2) for use with Evr-Green EV charging stations.

    Full text manual (for reference)

    Installation manual for Leviton's Single and Dual Mount Back-to-Back Pedestal (Cat. Nos. EPED1, EPED2) — for use with EV320, EV32W, EV480, EV48W, and EV48S Evr-Green® Electric Vehicle Charging Stations.

    Warnings

    Electrical hazard!

    • The installation, commissioning, and maintenance of the charging station may only be performed by correctly trained, qualified, and authorized electricians who are fully responsible for compliance with existing standards and installation regulations. Observe the instructions given for selecting the location and the constructional requirements.
    • If the specifications for the location are not observed, this can result in death, serious physical injury, or equipment damage if corresponding precautionary measures are not met.
    • The back-to-back pedestal must always be fitted with two charging stations.

    This installation manual is intended for qualified personnel only. Adhere to the information and instructions in the manual about selecting the location, installation, and connection of the charging station.

    Installation

    2.1 Making Drill Holes

    1. Mark four (4) holes on the concrete foundation using the base-plate of the pedestal. Make sure the connection cable is located precisely underneath the opening in the base-plate.
    2. Drill four (4) mounting holes: Diameter 0.39 in. (10 mm); drill-hole minimum depth 3.31 in. (84 mm).
    3. Hammer the anchors (not included) so that they are flush with the floor.

    Base-plate hole layout dimensions: overall width 8.62 in. (219 mm), overall length 54.92 in. (1395 mm); hole spacing 7.87 in. (200 mm) and 10.63 in. (270 mm); offsets 3.67 in. (93.2 mm), 3.07 in. (78 mm), and 6.1 in. (155 mm) from reference edges.

    2.2 Thread in Cable

    Thread the connection cables from the bottom through the pedestal upwards through the cable opening.

    2.3 Anchoring

    1. Position the pedestal directly over the cable outlet.
    2. Anchor the pedestal to the foundation using four (4) sets of M8 nut, M8 flat washer, and M8 spring washer.

    2.4 Bracket Installation

    1. Insert the cable gland into the pedestal.
    2. Install the mounting plate to the pedestal with the screws provided.

    2.5 Connector Base and Hook Installation

    Use four (4) M5 x 22 mm screws to fix the connector base and hook in the corresponding position.

    2.6 Mounting and Connecting the Charging Station

    1. Mount the charging stations on the pedestal using two (2) M5 x 12 mm screws on both sides of the charger.
    2. Release the four (4) M5 x 12 mm screws from the wiring window at the back.
    3. Thread the connection cables from the bottom, through the pedestal, upwards through the cable opening.
    4. Perform the electrical connection and commissioning in accordance with the charging station's own instructions.
    5. Fix the four (4) M5 x 12 mm screws to finish the installation.

    FCC Statement

    This device complies with Part 15 of the FCC Rules and ISED License-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by Leviton could void the user's authority to operate the equipment.

    This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or television reception, the user is encouraged to try correcting the interference by reorienting/relocating the receiving antenna, increasing separation between the equipment and receiver, connecting the equipment to an outlet on a different circuit, or consulting the dealer or an experienced radio/TV technician. This Class A digital apparatus complies with Canadian CAN ICES-3(A)/NMB-3(A).

    Warranty

    Leviton warrants to the original consumer purchaser that this product is free of defects in materials and workmanship under normal and proper use for one year from the purchase date. Leviton's only obligation is to correct such defects by repair or replacement, at its option. This warranty excludes labor for removal/reinstallation and is void if the product is installed improperly, overloaded, misused, opened, abused, or altered. For details, visit www.leviton.com or call 1-800-824-3005.

    For Canada: contact Leviton Manufacturing of Canada ULC, Attn: Quality Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9, or call 1-800-405-5320.

    Manufacturer Contact

    Leviton Manufacturing Co., Inc.
    201 North Service Road, Melville, NY 11747
    Technical Assistance: 1-800-824-3005 (USA) • 1-800-405-5320 (Canada)
    www.leviton.com