Installation instructions for the Interlogix / GE Security TX-8300-01-1 DesignLine Tri-Zone Sensor, protecting up to three zones (plus garage door tilt sensing) from a single wireless device.
Installation instructions for the Interlogix / GE Security TX-8300-01-1 DesignLine Tri-Zone Sensor — a wireless sensor that protects up to three separate zones from one device, with built-in garage door tilt sensing, tamper protection, and a low-battery LED indicator.
The DesignLine Tri-Zone Sensor provides:
Sensor components: N/C zone inputs, jumpers (1, 2, 3), a reed switch (1 zone), tamper switch, roller-ball tilt switch, and battery compartment.
Use a maximum of 18 ft. (6 m) of 24 AWG wire per zone (zones 2 and 3). Locate the sensor within 100 ft. (30 m) of the control panel if possible — open-air range is 500 ft. (150 m), though the environment can significantly reduce that.
Jumper 1 should be left in its factory-default position (do not remove). Jumpers 2 and 3 control zone learning behavior.
| J2 | J3 | Description |
|---|---|---|
| On | On | Sensor will learn in all three zones when you activate the tamper switch. |
| J2 | J3 | Description |
|---|---|---|
| Off | On | Select the zone to learn by faulting the desired zone. To use the reed or tilt switch, zone 1 must be learned first: Zone 1 = remove the magnet; Zone 2 = open zone 2 external contact; Zone 3 = open zone 3 external contact. Replace jumper 2 once zones are programmed. |
For zone 1, select either the reed switch (jumper 3 on) or the tilt switch (jumper 3 off).
The sensor can secure a garage door without running wires or using a reed switch. Program (learn) the sensor before mounting it.
| J2 | J3 | Description |
|---|---|---|
| On | Off | Tilt switch on in instant mode (no delay). |
| Off | Off | Tilt switch on in 1-minute delay. |
Program (learn) the sensor before mounting.
If needed, use the included spacer: mount it with the two provided screws and snap the magnet onto the spacer.
The sensor cover LED flashes every 5 seconds when a low battery condition is detected.
Mounting height of the standard-lens sensor may be anywhere within a range of 7 to 9 feet (2.1 to 2.7 m).
| Frequency | 319.5 MHz |
| Typical RF output power | 0.25mW EIRP |
| Battery type | 3V 1300 mAh lithium; replace with Panasonic CR123A |
| Typical battery life | 5 to 7 years with normal use |
| Low battery threshold | 2.5V ± .2V |
| Wire size / length | 24 AWG, 18 ft. (6 m) max. |
| Magnet gap | 0.5 in. (1.3 cm) max. |
| Supervisory interval | 70 minutes |
| Compatible panels | 319.5 MHz control panels/receivers |
| Dimensions (W × H × D) | 1.7 × 2.9 × 1.0 in. (43 × 75 × 25 mm) |
| Operating temperature | 14 to 120°F (-10 to 49°C); storage -20 to 140°F (-28 to 60°C) |
| Relative humidity | 0 to 90% noncondensing |
| Weight | 1.6 oz. (45 g) |
Complies with FCC Part 15 rules. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC ID: B4Z-TX-8300-01. IC: 1175C-TX830001.