September 08, 2026 3 min read
Data sheet for the Interlogix SafeAir 250-CO, a 12/24VDC hardwired carbon monoxide detector with SafeTest functional testing.
Data sheet for the Interlogix SafeAir™ 250-CO — a 12/24VDC hardwired carbon monoxide detector with SafeTest™ functional testing, designed to interface with any UL 985/864 listed intrusion or fire alarm system.
The SafeAir 250-CO uses an electro-chemical CO sensor with an on-board microprocessor that tracks CO levels over time, self-adjusts for environmental changes, and compensates for sensitivity drift over its service life. It connects to a Class 2 output from a control panel or auxiliary power supply and reports alarm and trouble conditions via relay to the panel and (if monitored) the central station.
Install per NFPA 720. Wall-mounted detectors: at least 5 ft. (1.5 m) up from the floor. Ceiling-mounted: at least 1 ft. (0.3 m) from any wall.
Do NOT install: within 10 ft. (3 m) of a fuel-burning appliance; near air conditioners, heating registers, or ventilation sources; where furniture/draperies obstruct airflow; or in a recessed area.
Four-wire device requiring a Class 2 output from a control panel or resettable auxiliary power supply listed to UL 985 or 864. All wiring must conform to NFPA 70 (National Electric Code), UL 2075, NFPA 720, and local codes, using 14–22 AWG wire. Supports single-device/single-zone, multiple-devices/single-zone, and multiple-devices/separate alarm-trouble-zone wiring configurations (see full wiring diagrams in the downloadable PDF).
Warning: Connect the CO detector only to a zone dedicated exclusively to CO detection, monitored 24 hours a day. Do not connect to an initiating circuit with fire or security devices. Failure to properly install, test, and maintain a CO detector may result in loss of life.
| Spec | Value |
|---|---|
| Input voltage | 12 or 24 VDC, supplied by control panel or resettable auxiliary power supply |
| Current draw | Normal 20 mA; Alarm 40 mA (75 mA in test) |
| Alarm relay | 150 mA at 33 VDC, Form C, Zone rated |
| Common trouble relay | 150 mA at 33 VDC, normally open held closed with power applied |
| CO alarm response time | 70 PPM: 60–240 min · 150 PPM: 10–50 min · 400 PPM: 4–15 min |
| Sounder | 85 dB, temporal-4 pattern |
| Compatible control panel | Listed to UL 985 or 864 |
| Electrical box | North American 2½ in. (64 mm) deep, 1-gang |
| Wire size | 14 to 22 AWG (0.25–2.0 mm²) |
| Dimensions (detector) | 3.1 x 4.6 x 1.3 in. (7.8 x 11.7 x 3.2 cm), 4.7 oz. (133 g) |
| Dimensions (adapter plate) | 4.5 x 6.5 x 0.2 in. (11.4 x 16.5 x 0.5 cm), 1.6 oz (46 g) |
| Color | White |
| Operating environment | 32–104°F (0–40°C), 0–90% RH noncondensing |
| UL rating | Listed to ANSI/UL 2075 |