September 08, 2026 3 min read
Installation instructions for the Inovonics EN1238D EchoStream Double Condition Pendant Transmitter.
Installation instructions for the Inovonics EN1238D EchoStream® Double Condition Pendant Transmitter — a two-button wireless pendant that sends two distinct conditions.
The EN1238D is a two-button pendant transmitter able to send two conditions. It must be used with an EchoStream EN4000 or EN4200 serial receiver, or the EN6040 network coordinator. The application controller (e.g. control panel) must be designed to accept the two conditions.
Caution: When pressing Reset, don't also touch the frequency band selection pins — this can inadvertently set the pendant to the wrong frequency band.
The EN1238D must be registered with the system to be monitored and supervised. When supervised, it sends a check-in message to the serial receiver or network coordinator — every 12 minutes for 868MHz (Europe) pendants, every three minutes for all others. Each pendant has a unique factory-programmed ID number; refer to the control panel's installation instructions for registration details.
Caution: Test the EchoStream system regularly by activating both EN1238D conditions and confirming the appropriate response.
To send the first condition, press and hold either the left or right pendant button for one second. To send the second condition, press and hold both buttons simultaneously for one second. Condition signals are transmitted multiple times, indicated by the blinking transmission LED. When the buttons are released, the transmitter sends a condition restoral signal. Inovonics recommends testing the transmitter at least once per week.
To convert the belt clip to a belt loop, secure the bottom of the belt clip to the housing with a coarse thread screw.
| Spec | Detail |
|---|---|
| Typical Battery Life | 3-5 years |
| Battery Type | BAT608 — Panasonic CR2 or equivalent |
| Operating Environment | 0 to 60°C (32 to 140°F), noncondensing |
This equipment complies with FCC Part 15 Class B limits and Industry Canada license-exempt RSS standards. Operation is subject to two conditions: (1) this device may not cause harmful interference, and (2) it must accept any interference received, including interference that may cause undesired operation.
Inovonics Wireless Corporation warrants its products to conform to specifications and be free of defects in materials/workmanship under normal use for 36 months from the date of manufacture. Within the warranty period, Inovonics will repair or replace the warranted product at its option. The warranty is void in cases of improper installation, misuse, failure to follow instructions, alteration, accident, tampering, or repair by anyone other than Inovonics. Contact your authorized distributor for a Return Material Authorization (RMA).
Inovonics Wireless — support@inovonics.com — (800) 782-2709 — www.inovonics.com