    Installation and Operation Manual for the Inovonics EN1223D EchoStream® Double-Button Panic Alarm.

    Full text manual (for reference)

    Installation and Operation Manual for the Inovonics EN1223D EchoStream® Double-Button Panic Alarm — Inovonics' smallest, lightest, and most versatile wireless panic pendant transmitter.

    Overview

    Inovonics EN1223D panic alarm transmitters are designed for professional security installations. For UL installations, refer to the EN4216MR Installation and Operation Manual, the EN4232MR Installation and Operation Manual, or the EN7285 Installation Instructions instead of this document.

    Transmitter Components

    • A — Transmit LED: blinks during signal transmission
    • B — Activation Buttons: two buttons, pressed simultaneously to trigger an alarm
    • C — Frequency Band Selection Pins
    • D — Reset Button
    • E — Battery

    Installation and Startup

    Installation Notes

    • Designed to be maintained by professional security technicians.
    • Intended for indoor use only.
    • Manually test all products weekly.

    Install / Replace the Batteries

    1. If present, remove the 3 housing screws on the back of the transmitter.
    2. Open the housing.
    3. Install the new batteries, ensuring the positive terminals (+) face the indicated side of the holder.

    Select the Frequency Band

    EchoStream products use a range of radio frequencies and must be configured for your geographic area by placing a selection jumper on the appropriate frequency band selection pins:

    Jumper Position Frequency Range Region
    Top two pins, marked NZ 921-928 MHz New Zealand
    Bottom two pins, marked AU 915-928 MHz Australia
    Jumper off pins 902-928 MHz North America

    Note: only devices set for North America are configured for UL installations.

    After setting the jumper, press the Reset button to complete configuration.

    ⚠ Caution: When pressing the Reset button, make sure you don't also touch the frequency band selection pins — doing so while pressing Reset can inadvertently set the transmitter to the wrong frequency band.

    Register the Transmitter

    The transmitter must be registered with the system to be monitored and supervised. When supervised, it sends a check-in message to the serial receiver or network coordinator every three minutes. Each transmitter has a unique factory-programmed identification number. Refer to the receiver's installation instructions for details on registering a transmitter — typically, press the Reset button when prompted by the receiver.

    Caution: after registration, test the transmitter by activating each condition and confirming an appropriate response.

    Operate the Transmitter

    To activate double-button transmitters, press both buttons simultaneously. Alarm signals transmit multiple times and are indicated by the blinking transmission LED. When the buttons are released, the transmitter sends an alarm restoral signal. To test the transmitter, activate the alarm by pressing the buttons.

    Specifications

    Spec Value
    Dimensions 5.6 x 4.8 x 1.8 cm (2.2 x 1.9 x 0.72")
    Operating Temperature 0 to 60°C (32 to 140°F), 90% RH non-condensing
    Typical Battery Life 3-5 years
    Battery Type (BAT609) Renata CR2450, Panasonic CR2450
    Power Requirement 3 VDC, 60 mA
    UL Listings UL 1023, ULC/ORD-C1023-74
    Compatible Receivers EN4216MR, EN4232MR, EN7285

    FCC / Industry Canada Compliance

    This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules, providing reasonable protection against harmful interference in a residential installation. If this equipment causes interference to radio or television reception, try reorienting/relocating the receiving antenna, increasing separation between equipment and receiver, connecting to an outlet on a different circuit, or consulting the dealer/an experienced radio/TV technician.

    This device complies with Part 15 of the FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to: (1) this device may not cause interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

    Warranty and Disclaimer

    Inovonics Wireless Corporation warrants its Products to conform to specifications and be free of defects in materials and workmanship under normal use for 36 months from the date of manufacture. Within the warranty period, Inovonics will repair or replace, at its option, all or any part of the warranted Product; Inovonics is not responsible for dismantling and/or reinstallation charges. To exercise the warranty, work through your authorized distributor to obtain a Return Material Authorization (RMA) number. The warranty is void in cases of improper installation, misuse, failure to follow instructions, alteration, accident, tampering, or repair by anyone other than Inovonics.

    Contact Inovonics Wireless technical services: E-mail support@inovonics.com, Phone (800) 782-2709 / (303) 939-9336. © Inovonics, 2011 — www.inovonics.com. Document 05583C, April 8, 2011.