  • HomeSeer HS-LS100+ Z-Wave Leak Sensor — Manual

    September 08, 2026 3 min read

    Manual for the HomeSeer HS-LS100+ Z-Wave Leak Sensor — installation, Z-Wave inclusion, configuration parameters, and specifications.

    Full text manual (for reference)

    Manual for the HomeSeer HS-LS100+ Z-Wave Leak Sensor — a compact, battery-powered leak/shock sensor with magnetic wall mount and wired probe assembly options.

    Overview

    HS-LS100+ is a compact, easy-to-install leak sensor designed to control other Z-Wave devices directly, or to work with a variety of Z-Wave certified home controllers to launch automation events or scenes.

    Applications

    • Activate Z-Wave devices such as sirens or water valve controllers when a leak is sensed.
    • Trigger home automation events ("scenes"/"automations"/"robots") when a leak is sensed.

    Configuration

    HS-LS100+ is battery powered and includes a Z-Wave network button, LED indicator, and a magnetic wall mount/wired probe assembly. It may be deployed as a free-standing sensor (using built-in probes) or as a wired remote sensor (via the wall mount/wired probe assembly).

    Z-Wave Network Installation

    Remove the back cover by rotating counter-clockwise and install 1 ER14250 battery (included). Include the sensor into your Z-Wave network using the steps below, then replace the back cover.

    HS-LS100+ may be included as a "secure" or "non-secure" device.

    • Secure Inclusion (recommended if your controller supports S0/S2 encryption): Put the controller into Z-Wave inclusion mode, then press and hold the Z-Wave network button for 5 seconds and release. Wait for inclusion to finish.
    • Non-Secure Inclusion: Put the controller into inclusion mode, then quickly press and release the network button once.
    • Exclusion: Put the controller into exclusion mode, then quickly triple-press the network button.
    • Factory Reset (if the controller is missing/inoperable): Press and hold the button for 20 seconds; release once the LED stops blinking and glows solidly.

    Physical Installation

    • Free-standing: Place the leak sensor on a flat horizontal surface where a leak might occur.
    • Remote installation: Install the included magnetic wall mount/wired probe assembly using the supplied mounting hardware, then attach the HS-LS100+ by aligning its 3 probes with the 3 holes in the mounting bracket. Position/install the wired probe where a leak might occur or where you wish to detect liquid.

    Sensor Operation

    • Leak sensor: Transmits a Z-Wave command when liquid is sensed, and another command when liquid is no longer sensed.
    • Shock sensor: Transmits a Z-Wave command when the unit is physically moved — useful for detecting removal/tampering.
    • Battery sensor: Reports battery level via Z-Wave every 43,200 seconds (12 hours) by default; interval adjustable (0–2,678,400 sec) via the Z-Wave tab of the root device in HomeSeer.

    HS-LS100+ supports Group 1 association, which reports the sensor's status and battery level (if running on batteries).

    Advanced Configuration Parameters

    Accessible via the "Root device" in a HomeSeer System. Before adjusting these settings, tap the network button 4 times to wake the unit.

    Param Description Default Available Values
    14 Enable/disable Basic Set Command 0 (disable) 0=disable, 1=enable
    15 Value for Basic Set Command 0 (sends 255 when leak sensed) 0 or 1 (sends 0 when leak sensed)
    17 Leak report interval 5 min 0=disable, 1–255 min
    18 Enable shock sensor 0 (disable) 0=disable, 1=enable
    19 Temperature report interval 0 (disable) 0=disable, 1–255 min
    20 High temperature trigger value 1040 (104°F) -670 to 2570 (-67 to 257°F)
    22 Low temperature trigger value 320 (32°F) -670 to 2570 (-67 to 257°F)
    24 Enable blinking LED when alarm triggers 1 (enable) 0=disable, 1=enable
    32 Low battery threshold 20% 10–50%

    Note: Parameters 18 (Enable Shock Sensor) and 19 (Temperature Report Interval) are disabled by default to conserve battery life.

    Specifications

    Spec Value
    Operating temperature range 0°C to 40°C
    Z-Wave frequency / range 908 MHz (US) / up to 300 ft line of sight
    Z-Wave certification Z-Wave Plus
    Power Requires (1) ER14250 battery
    Dimensions (main unit) 2.75 x 2.75 x 0.75 in.

    Warranty

    HomeSeer Technologies, LLC will repair or replace, at its option, any part of the device proving defective in workmanship or material under normal use (USA, excluding Alaska and Hawaii) for one year from the date of purchase. Contact HomeSeer to obtain a return authorization before shipping the device for service.

    Manufacturer

    HomeSeer — 10 Commerce Park North, Unit 10, Bedford, NH 03110. Web: HomeSeer.com