September 08, 2026 3 min read
Installation and operating instructions for the HAI UPB 300W Lamp Module (model 59A00-1), a plug-in dimmer using UPB two-way powerline communication.
The HAI UPB™ Lamp Module (model 59A00-1, HAI 300W Lamp Module) is a plug-in dimmer incorporating UPB™ two-way powerline communication technology, allowing remote control by any UPB™-compatible controller. It is intended for use with incandescent or tungsten loads only. The module has one UPB™-controllable outlet that senses the lamp's local on/off switch, allowing it to turn the lamp back on even after it was switched off via UPB™ control; it can also transmit UPB™ messages (including current light level) when the local switch is used.
Each Lamp Module can be configured to fit an individual's lifestyle and can store up to 16 preset light levels and fade rates for lighting scenes. It can also be set to a non-dimming mode to control loads such as fluorescent lights.
The HAI UPB™ Lamp Module simply plugs into a standard 120VAC wall outlet. The total load on the UPB™-controlled outlet must not exceed 300 Watts.
By default, the Lamp Module senses the lamp's local on/off switch and can turn the lamp on even after it was turned off via UPB™ control. This feature may not work for all load types (e.g., fluorescent) and may need to be disabled.
A multi-color LED is normally lit blue when the load is off, and turns off when the load is on or set to any level 1–100%.
| Step | Operation |
|---|---|
| 1 | Press and hold the pushbutton for at least 3 seconds to enter Test Mode. |
| 2 | LED continuously flashes magenta to indicate Test Mode (auto-exits after 5 minutes). |
| 3 | Press the pushbutton once to turn the UPB™-controlled outlet on and off. |
| 4 | Press and hold the pushbutton for at least 3 seconds to exit Test Mode. |
| Step | Operation |
|---|---|
| 1 | Press the pushbutton switch quickly 5 times. |
| 2 | The Lamp Module flashes the load once and blinks the LED blue to indicate Setup Mode (auto-exits after 5 minutes). Configure via an HAI controller or PC running UPB™ UPStart configuration software. |
| Step | Operation |
|---|---|
| 1 | Press the pushbutton switch quickly 5 times. |
| 2 | Load flashes once, LED blinks blue — ready to set factory defaults. |
| 3 | Press the pushbutton quickly 10 times to reset. |
| 4 | Load flashes once, LED blinks red — reset complete. |
| 5 | Press the pushbutton once more to stop the LED blinking. |
| Spec | Value |
|---|---|
| Incandescent Loads Dimming | Yes |
| Inductive Loads Dimming | No |
| Fluorescent Loads Non-Dimming | Yes (configurable) |
| Power Maximum Dimming | 300W |
| Current Maximum Non-Dimming | 2.5A |
| Connections | Standard receptacle |
| Dimensions | 3" x 2" x 1.3" |
| Weight | 0.25 lb. |
| Mounting | Plug-in |
| Input Power | 120 ± 12 VAC, 60 ± 3 Hz |
| Operating Temperature | -40°F to 104°F |
HAI warrants this product against defects in material and workmanship for 2 years from date of purchase; HAI will repair or replace at its sole option. Warranty does not cover removal/reinstallation costs, normal wear, damage while in the user's possession (other than a covered defect), improper installation, alterations, misuse, or abuse. Implied warranties, including merchantability and fitness for a particular purpose, are limited to 2 years from purchase date. For warranty/repair service within the continental United States, send the defective unit (postage prepaid, with description of trouble and contact info) to: HAI, Repair Department, 4330 Michoud Blvd, New Orleans, LA 70129. Outside the continental U.S., contact an authorized distributor.