  • GE Security PrecisionLine RCR-PET Dual Technology Motion Sensor — Installation Instructions

    August 31, 2026 4 min read

    Installation Instructions for the GE Security PrecisionLine RCR-PET dual-technology (radar + PIR) motion sensor with pet immunity up to 80 lbs.

    Full text manual (for reference)

    Installation Instructions for the GE Security PrecisionLine RCR-PET Dual Technology Motion Sensor — a pet-immune (up to 80 lbs.) combination range-controlled radar (RCR) and passive infrared (PIR) motion detector for use with UL-listed security control panels.

    Description

    The PrecisionLine RCR-PET combines radar (RCR) technology with a PIR system to increase false-alarm immunity by sensing human-sized objects within a specified range. Both the RCR and PIR systems must be triggered together to set off an alarm. The sensor runs on a 12VDC power supply provided by a UL-listed control panel.

    Features

    • Pet immune up to 80 lbs.
    • Selectable range up to 35 feet (10.7m) via an internal jumper to optimize coverage
    • Multi-color LED indicator showing detector status
    • Opaque Fresnel lens that blocks visible light

    Parts Included

    • RCR-PET sensor
    • 1 screw to join the case halves
    • 2 factory-installed jumpers

    Coverage Pattern

    The sensor covers a 90° radius, with radar/PIR range settings selectable at 9', 18', 27', or 35 feet (2.7m / 5.5m / 8.2m / 10.7m) from the sensor, both in top-down and side-view coverage patterns. Side-view coverage extends down to floor level at increasing distance from the mount, tapering off around 4° elevation at the maximum 35' range.

    Selecting a Location

    • Mount so expected intruder movement falls within a 90° radius in front of the sensor.
    • Mount on a stable surface 7 to 8 feet (2.1 to 2.4m) high.
    • Do NOT mount within 2 feet (0.6m) of metallic objects.
    • Do NOT place objects in front of the sensor that block a clear line of sight.
    • Avoid exposure to false-alarm sources: moving/vibrating objects (fans, pulleys, conveyor belts); electronic fields (motors, high-voltage equipment); water spray or corrosive environments; heat sources (heaters, radiators) in the field of view; windows in the field of view; strong air drafts (fans, A/C).
    • When installing multiple sensors: do NOT mount sensors facing each other; mount at least 20 feet (6.1m) apart. Back-to-back mounting is not recommended, but if required, use the 9-foot range, mount at least 1 foot (0.3m) apart, and walk-test the installation.

    Installing the Sensor

    All wiring must conform to the National Electric Code (NEC) and/or applicable local codes.

    Important: Do NOT use this device for safety interlock applications.

    1. Run security system wiring to the sensor location.
    2. Lift off the front cover/electronic module; remove the nameplate and loosen the screw if necessary.
    3. Caution: Discharge all static electricity before handling the circuit board — touch a grounded, bare metal surface or wear a grounding strap first.
    4. Set the circuit board jumpers as needed (see Setting the Jumpers below).
    5. Remove the appropriate wiring/mounting knockouts from the back cover — the sensor can be mounted on a flat wall or in a corner.
    6. Pull the wires through the knockout holes and attach the base to the wall with the two provided screws (use anchors if necessary).
    7. Strip 1/4 inch (6.4mm) of insulation from each wire.
    8. Run each wire through the strain relief and under the appropriate screw terminals on the base; tighten the screws.
    9. Align the tabs on the bottom of the cover/electronic module with the base and snap the module firmly onto the base.
    10. Tighten the screw and replace the nameplate.
    11. Apply power — the LED lights green for about 25 seconds, then goes out.
    12. Walk-test the coverage pattern by walking through the intended coverage area and verifying the sensor alarms (see Understanding the LED below).

    Setting the Jumpers

    J2 — Range Selection

    Use the jumper to cover the center pin and the pin for the desired range:

    • No jumper = 27 feet (8.2m) and under
    • 35 feet (10.7m) and under — factory default
    • 18 feet (5.5m) and under
    • 9 feet (2.7m) and under

    Important: Set J2 as close to the intended coverage range as possible — overshooting the coverage area may cause false alarms.

    J3 — LED

    • ON = LED enabled (factory default)
    • OFF = LED disabled

    Pet Immunity

    When mounted properly, the RCR-PET provides false-alarm immunity to dogs and similar animals. Immunity depends on the animal's size, temperature, and coat length — a warm-blooded, short-haired dog is less immune to false alarms than a similarly-sized dog with a longer coat, so short-haired dogs must be smaller/lighter to remain covered.

    Long Hair (2" coat, up to 80 lbs.) Medium Hair (1.5" coat, up to 50 lbs.) Short Hair (1" coat, up to 30 lbs.) Not Recommended (use pet-alley application)
    Chinook Collie Basenji Doberman
    Husky English Setter Border Terrier Great Dane
    Poodle Pointer Cocker Spaniel French Bulldog
    Retriever Pug Mini Bull Terrier Greyhound
    Sheepdog Toy Poodle Welsh Corgi Mastiff
    Shepherd Weimaraner Pit Bull
    Cats St. Bernard

    Pet immunity is not verified by UL.

    Understanding the LED

    LED Color Status
    Red PIR and RCR detection — sensor in alarm, relay switched
    Green PIR detection only (no alarm)
    Yellow RCR detection only (no alarm)

    After 30 minutes, the LED only indicates an alarm condition. Drop power to reset the walk-test timer.

    Accessories

    SB01 Swivel-Mount Bracket — an optional ceiling-mount swivel bracket for ceiling-mount applications requiring 90° coverage.

    Maintaining the Sensor

    When installed and used properly, the sensor provides years of service with minimal maintenance. Walk-test the sensor annually to ensure proper operation.

    Specifications

    Input Voltage 8.5 to 18VDC (UL: 10 to 16VDC)
    Typical Current 20mA
    Maximum Current 27mA
    Electrical Configuration Form A
    Relay Rating 40VDC, 300mA max., 6W load max.
    Detection Range 35' (10.7m) x 90°
    Target Velocity 0.5 to 5 ft/sec
    Alarm Duration 5 sec. ± 10%
    Mounting Height 7' to 8' (2.1m to 2.4m)
    Operating Temperature 32°F to 122°F (0°C to 50°C)
    Relative Humidity 5 to 93% non-condensing
    Dimensions 2.8" W x 5.1" H x 2.3" D (71mm x 130mm x 58mm)
    Weight 6 oz (170g)
    Color White
    Field Wiring Size 12-24 AWG
    Listings C-UL US

    Product Ordering

    RCR-PET PrecisionLine Dual Technology Motion Sensor with Pet Immunity up to 80 lbs., Form A
    SB01 (accessory) Swivel-Mount Bracket

    FCC Compliance

    This device complies with Part 15 of the FCC rules. Operation is subject to: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: CGGAA2

    Contact

    GE Security, 12345 SW Leveton Drive, Tualatin, OR 97062 — 503-692-4052, USA & Canada: 800-547-2556

    Tech Support: 800-648-7424, FaxBack: 800-483-2495, www.ge-security.com