September 08, 2026 3 min read
Installation instructions for the Ecolink WST-232 345 MHz door/window sensor with auxiliary hardwired input, compatible with Honeywell and 2GIG receivers.
Installation instructions for the Ecolink WST-232 Wireless Contact with External Input — a 345 MHz door/window sensor with an auxiliary hardwired input, compatible with Honeywell and 2GIG receivers.
| Spec | Value |
|---|---|
| Frequency | 345 MHz |
| Battery | One 3Vdc lithium coin cell CR2032 (225 mAh) |
| Battery Life | 5–8 years |
| Magnet Gap | 5/8" max |
| External Contact Input | Normally Closed |
| Operating Temperature | 32°–120°F (0°–49°C) |
| Operating Humidity | 5–95% RH non-condensing |
| Compatibility | Honeywell and 2GIG receivers |
| Supervisory Signal Interval | ~60 min |
Set your panel into program mode (refer to your specific alarm panel manual for details). When prompted by the panel:
Alternately, the 7-digit serial number printed on the back of the unit can be manually entered into the panel. For 2GIG systems, the equipment code is 0637.
Included with the contact is double-sided tape for the sensor and the magnet. For reliable bonding, ensure the surface is clean and dry. Apply the tape to the sensor and then to the desired location, applying firm pressure for several seconds. It is not recommended to mount the tape at temperatures below 50°F, though after 24 hours the bond will hold at low temperatures.
The sensor's marked side (3 lines) indicates the location of the reed switch — mount the magnet facing this side, no further than 5/8" away. A mounting back plate with screws is also provided: screw the back plate onto the mounting surface and snap the sensor onto it.
To remove the sensor from the mounting plate: remove the cover, then use a small flat-head screwdriver to press the plastic tab (near the battery, at the bottom of the sensor) toward the wall and slide the sensor up.
Note: Do not use the tape to secure the mounting plate to the wall.
The contact ships assembled with a white cover; an optional brown cover is included. To swap covers, slide the front cover to disengage it from the sensor, then remove and replace with the desired cover, ensuring the "Top" marking (on the inside of the cover) points away from the battery. You should hear a click when the cover engages/disengages. The magnet cover can be swapped the same way — gently pry the white cover off with a flat-head screwdriver and snap the brown cover in place.
This equipment has been tested and found to comply with the limits for Class B digital devices, pursuant to Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
If this equipment causes harmful interference to radio or television reception, try: re-orienting or relocating the receiving antenna, increasing separation between the equipment and receiver, connecting the equipment to an outlet on a different circuit, or consulting the dealer/an experienced radio-TV contractor for help. Warning: Changes or modifications not expressly approved by Ecolink Intelligent Technology Inc. could void the user's authority to operate the equipment.
FCC ID: XQC-WST232 · IC: 9863B-WST232
Ecolink Intelligent Technology Inc. warrants this product against defects in material and workmanship for 5 years from the date of purchase. This warranty does not cover damage from shipping/handling, accident, abuse, misuse, misapplication, ordinary wear, improper maintenance, failure to follow instructions, or unauthorized modification. Ecolink will repair or replace defective equipment (at its option) upon return to the original point of purchase; liability is limited to replacement of the defective product.
Manufacturer: Ecolink Intelligent Technology Inc. · 2055 Corte Del Nogal, Carlsbad, CA 92011 · 1-855-632-6546 · www.discoverecolink.com