  • Channel Vision P-1014 — 1x4 CAT5 Audio Distribution Module Instructions

    September 08, 2026 4 min read

    Instructions for the Channel Vision P-1014, the 1x4 CAT5 Audio Distribution Module at the heart of a multi-room CAT5 audio system.

    Full text manual (for reference)

    Instructions for the Channel Vision P-1014, a 1x4 CAT5 Audio Distribution Module — the heart of a Channel Vision multi-room CAT5 audio system.

    Overview

    The P-1014 is a 1x4 distribution module that delivers power and audio signals to 4 amplified keypads (model AB-114 or AB-124). Four IR emitter outputs on the P-1014 allow IR signals detected by an AB-124 keypad to control source devices such as CD players and AM/FM tuners.

    Features

    • Both RJ-45 and 110 punch-down connectors for easy setup
    • Integrated single-source audio input
    • 4 common IR emitter outputs
    • Expansion connectors to hook up additional units for more CAT5 audio outputs
    • Connection LEDs light when an amplified keypad is attached — only 4 keypads (1 per zone) can be connected at a time; if both RJ-45 and 110 connectors are used, RJ-45 has priority

    Ports: Local Input, System Input (from an AB-301, AB-202, or expansion output), optional Status power connection, and 24VDC power supply connection (included). Four Global IR emitters flash when any keypad in the system detects an IR signal.

    How It Works

    Channel Vision's CAT5 Audio System uses Category 5 cable to distribute power, audio, and IR control signals. Power and line-level audio are delivered to keypads, which amplify the signal and distribute it to a pair of speakers. Keypads have IR sensors that detect signals from standard handheld remote controls; those IR signals are then transmitted through the CAT5 wire back to an input module, which activates IR emitters that recreate the remote's signal directly at the source device.

    Required Components

    • Amplified Keypad (AB-114 or AB-124) — 1 per speaker pair. Drives speakers, controls volume, and relays IR information. Mount in a single-gang low-voltage ring or deep J-box (if required by code). Compatible with decorator-style wall plates. Blue LEDs show volume level; the keypad completely mutes when the bottom LED is off (no amplifier hiss like some other systems).
    • AB-T2454 — Power supply. 1 per P-1014, 120–240VAC (included with the P-1014).

    Optional Components

    • AB-202 — Single source module. 1 per system; interfaces sources to the system. Mount near audio components (CD player, receiver, etc.).
    • AB-301 — Universal input module. Provides local source input in any room and/or replaces the AB-202 as the system input. Great for connecting local sources — TVs, MP3 players, computer sources, etc.
    • A0501 — Remote control. Compatible with AB-114, AB-124, P-1044, and A4601.
    • IR-3002 & IR-3001 — Single and dual head IR flashers. Use one head per source to control from the remote room.
    • 5015 — Status power supply. Plugs into a switched outlet on the receiver. When the receiver is turned off, the entire system mutes. (If a supply is plugged into the status input and unpowered, the system mutes.)

    Basic System

    Make all connections before applying power. Most A/V receivers have a "Tape Monitor" or "Room 2" output that can feed directly into the local input on the P-1014. This input is audio-sensed, so the keypad mutes when no signal is present. Both 110 and RJ-45 connectors are provided for convenience, but only 4 amplified keypads (1 per zone) can be powered at any one time. The LED next to the active output lights when a keypad is connected.

    Advanced System

    When using an AB-202 with the P-1014, the local source input can serve as a secondary input that overrides signals from the AB-202 whenever audio is present — useful as a whole-house paging input (feeding a second source or paging system).

    P-1014 Special Features

    • LEDs light when audio is sensed on the corresponding input (System or Local).
    • The priority switch determines which input is heard (System or Local) when audio is sensed on both.
    • Expand the system by connecting a CAT5 jumper from the expansion output of the first P-1014 to the System input of a second P-1014, using either RJ-45 or 110 connectors.
    • Optional Status power input: if a plug is connected with no power present, keypads mute; if connected with power present, keypads do not mute; if nothing is plugged in, the system works normally.
    • Keypad connection LEDs: LED below the 110 connector lights if a keypad is attached there; LED above the RJ-45 connector lights if attached there. If a keypad is attached to both, only the RJ-45-connected keypad is active.
    • A maximum of 4 keypads (1 per zone) can be powered from each P-1014.

    Mounting Options

    The Channel Vision P-1300 (Pro-series) is a hinged rack-mount plate designed for a standard 19" rack, purpose-built to house the P-1014 — it hinges open for a clean look and easy servicing access. Alternatively, the P-1014 can be mounted in a standard structured wiring enclosure or screwed directly to a wall/flat surface (cut or remove the nylon snap pin and install screws in the empty holes).

    Specifications (typical)

    • Power supply voltage: 24 VDC
    • Status power voltage: 12 VDC
    • Audio input max level: 5 Vp-p
    • IR frequency range supported: 30 kHz – 56 kHz
    • Dimensions: 6"W x 6.5"H x 1.25"D

    Warranty

    Channel Vision Technology will repair or replace any defect in material or workmanship occurring during normal use, with new or rebuilt parts, free of charge in the USA, for two years from the date of original purchase — no mail-in warranty card needed. Excludes shipping damage, failures caused by other manufacturers' products, and failures from accident, misuse, abuse, or alteration. Warranty applies only to the original purchaser; proof of purchase date is required for warranty repairs.

    Mail-in service requires a Return Authorization number obtained in advance by calling (800) 840-0288 toll free.