September 08, 2026 1 min read
Step-by-step wire installation instructions for the Automated Fenestration Inc. RS Series (RS-2 / RS-4) window actuator control panel.
Wire installation instructions for the Automated Fenestration Inc. (AFI/UCS) RS Series Control Panel (RS-2 and RS-4 models).
Connect 110VAC to the panel's power supply module: the 787-732 unit for the RS-2 panel (one module), or two 787-732 units for the RS-4 panel (one per pair of groups). Wire colors depend on the actuator model in use:
| Terminal | Wire Color (Set A) | Wire Color (Set B) |
|---|---|---|
| LOAD (L) | Brown | Black |
| NEUTRAL (N) | Blue | White |
| GROUND (G) | Green/Yellow | Green/Yellow |
Which wire-color set applies depends on the specific actuator model being installed — match colors to the actuator manufacturer's documentation.
Connect actuators to all groups (Group 1, Group 2, Group 3, and Group 4 on the RS-4; Group 1 and Group 2 on the RS-2):
Connect the control wires to the General Command block and to each group's command terminals to verify correct operation:
Test each group individually by triggering Open/Common/Close to confirm the actuators respond correctly before final closeout.
Automated Fenestration Inc. · Sales@AutomatedFenestration.com · www.AutomatedFenestration.com