September 08, 2026 5 min read
Installation and operation manual for the ABB-free@home LS-1.1 wireless light switch, including wiring diagrams, setup, and factory reset instructions.
Installation and operation instructions for the ABB Light Switch LS-1.1, part of the ABB-free@home™ wireless smart home system. This device switches lighting and general-purpose fan loads and connects wirelessly to the free@home network.
The ABB Light Switch is used to switch electrical loads. It has a wireless control unit that connects it to the ABB-free@home system. For information about the many functions of this device, see the system manual at www.abb.com/freeathome.
| Wire Color | Function |
|---|---|
| Black | Hot/Live (120VAC) |
| White | Neutral |
| Blue | Binary Input |
| Red | Load Output |
| Green | Ground |
After installation, the Light Switch will immediately allow the lamp to function. To control the switch wirelessly, it must be added to the free@home network. Detailed setup information is available in the technical reference manual and the online help for the System Access Point (SysAP) at www.abb.com/freeathome.
The rocker and bezel of the device can be exchanged. Turn the power OFF before removing the adapter rocker with a screwdriver. Turn the power ON after the rocker and bezel have been reassembled.
Install according to national and local electrical codes.
When there is no ground connector in the wall box, the National Electrical Code (NEC®) allows a control to be installed as a replacement ONLY IF: 1) a non-metal, non-burning faceplate is attached with non-metal screws, OR 2) the circuit is protected by a ground fault circuit interrupter (GFCI). Be sure to cap or remove the green wire before screwing the control into the wall box.
To clean, wipe with a clean damp cloth. Do NOT use any chemical cleaning solutions.
| Specification | Value |
|---|---|
| Operating Voltage | 120 VAC, 60 Hz |
| Connection | Hot and Neutral wires required |
| Wireless Transmission Protocol | free@home, 2.400 - 2.483 GHz, Meshed |
| Ambient Operating Temperature | 23°F to 113°F (-5°C to 45°C) |
| Load Type | Max Rating |
|---|---|
| Incandescent or Halogen Lamp | 15 A (1800 W) |
| Magnetic Low Voltage Transformer (MLV) | 8 A (960 W) |
| Electronic Low Voltage Transformer (ELV) | 15 A (1800 W) |
| Fan (Max. 1 Fan Allowed) | 400 W |
| Fluorescent (Lamps without Compensation or Ballast) | 12 A (1440 W) |
| LED Lamps (Max. 20 Lamps Allowed) | 180 W |
This device complies with part 15 of the FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Modifications not expressly approved by the manufacturer could void the user's authority to operate this equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules, designed to provide reasonable protection against harmful interference in a residential installation. If this equipment causes harmful interference to radio or television reception, try repositioning the receiving antenna, increasing distance between equipment and receiver, connecting the equipment to a different circuit, or consulting a dealer/technician.
This equipment complies with FCC RF radiation exposure limits for an uncontrolled environment and should be installed/operated with a minimum distance of 20 centimeters between the radiator and your body.
ABB Electrification Products
860 Ridge Lake Boulevard, Memphis, TN 38120
abb.com/freeathome
Customer Service: 800-816-7809 (7:00 am – 5:30 pm CST, Monday-Friday) — elec_custserv@tnb.com
Technical Support: 888-385-1221, Option 1 (7:00 am – 5:00 pm CST, Monday-Friday) — freeathome_techsupport@us.abb.com