September 08, 2026 4 min read
Installation instructions and phone-control commands for the 2GIG Vario Voice Module, which provides audible status alerts and remote telephone keypad control.
Installation instructions and remote phone-control commands for the 2GIG Vario Voice Module — provides audible status announcements and lets any touch-tone phone act as a remote keypad for a 2GIG Vario System.
The 2GIG Vario Voice Module provides audible information about the status of the 2GIG Vario System and enables any remote touch-tone (DTMF) telephone to act as a keypad for the system. When a system event occurs (such as an alarm activation), the Voice Module notifies a system user by calling a specified telephone number and playing a pre-recorded announcement.
Note: For instructions on programming the Voice Module, see the 2GIG Vario System Installation Guide.
| SW | Description | Usage |
|---|---|---|
| 1 | Omit Tamper | Instead of a short with the TMP/COM terminal block |
| 2 | OPT | N/A |
| 3 | Test | Connected in parallel to all output channels. Enables listening to all played messages using a speaker (at least 32 Ω) connected between the Test Spkr and COM terminals. |
| 4 | Intern MIC | Select external or internal microphone for recording messages. On: records from the microphone on the Voice Module board. Off: records from a microphone on the 2GIG Vario Listen-in & Speak Module. |
The Voice Module board contains two connectors:
When connecting a Listen-in & Talk Module to the Voice Module, use one of the following wire types for the IN/OUT connections:
Wiring notes: Do not run wires close to power (110/230 VAC), high-voltage wiring, or communication lines. Do not wrap or roll wires. Ground all unused wires by connecting them to the COM terminal. Maximum distance between each Listen-in & Talk Module and the Voice Module is 10 meters; maximum of 10 Listen-in & Speak Modules can be connected to the 2GIG Vario System.
| Operating Voltage | 13.8 VDC ± 10% |
| Current Draw | 30 mA typical / 70 mA maximum |
| Operating Temperature | 0°C – 70°C |
| Main Panel Connection | Wire BUS, ≤ 300 m from main panel |
| Operation | Description | Action |
|---|---|---|
| Acknowledgment Message | Confirms message received; system calls the next Follow-Me number. | Press 1. |
| Acknowledge and Stop All Dialing | Acknowledges the event and stops calling other Follow-Me numbers. | Press 2, then enter code. |
| Acknowledge and Access Operations Menu | Lists available remote operation options. | Press 3, then enter code. |
| Listen In and Talk | Bi-directional communication. | Press 6, then 3, then enter code. |
| Repeat the Event Message | — | Press #. |
| Repeat the Acknowledge Menu | — | Press *. |
| Function | Action |
|---|---|
| Set all partitions | Press 1, press 1. |
| Set a selected partition | Press 1, press 9, enter partition number. |
| Un-set all partitions | Press 2, press 2. |
| Un-set a selected partition | Press 2, press 9, enter partition number. |
| Change Zone Omit status | Press 3, enter zone number, press #, press 9. |
| Change Follow-Me numbers | Press 5, enter Follow-Me number, press #, press 2, enter new number, press #, press 1. |
| Listen in to the premises | Press 6, press 1. |
| Talk to the premises | Press 6, press 2. |
| Listen in and talk | Press 6, press 3. |
| Record messages (5-message bank) | Press 7, press 1–5. |
| Record an opening message | Press 7, press 6. |
| Exit the system | Press 0. |
| Return to previous menu | Press *. |
| Repeat menu options | Press #. |
This device complies with Part 15 of the FCC's Rules. This equipment has been tested and found to comply with the limits for a Class B digital device, providing reasonable protection against harmful interference in a residential installation. Complies with FCC radiation exposure limits for an uncontrolled environment — avoid operating within 20 cm of the user.
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the condition that the device may not cause interference and must accept any interference received.
This Nortek Security & Control product is warranted against defects in material and workmanship for two (2) years — extending only to wholesale customers who buy direct from Nortek Security & Control LLC or through its normal distribution channels, not a consumer warranty. All returns require a Return Authorization Number (RA#) — contact Returns at 1-855-546-3351.
Inquiries: Nortek Security & Control, 1950 Camino Vida Roble, Suite 150, Carlsbad, CA 92008-6517, USA · 800-421-1587