BLINK
OUTDOOR LIGHTS WHEN A SECURITY PANEL GOES INTO ALARM MODE
Universal UPB Blink Light Module for Security Alarm Panels
This project will blink your outdoor lights when your security panel
goes into alarm mode. It requires minimal wiring and gives most
alarm panels the ability to trigger lights.
The SAUMI32W Input Output module is a plug-in module designed to
transmit the status of low voltage inputs or contact closures, and
to control the operation of low voltage actuators based on digital
commands received over the power line. It is useful for detecting
events such as ringing phones or doorbell or siren, for monitoring
alarm switches on doors and windows or sensing audio signals from
a sound system.
|
 |
 |
| WHAT YOU NEED: |
|
 |
 |
|
Input/Output module (programmed
via UPStart software) SKU: SAUMI32W
Order
Now >>
|
 |
|
|
|
|
 |
 |
|
SAI Transceiver Switch (programmed
via UPStart software)
SKU: SAUS1130W
Order Now >> |
 |
|
|
HOW TO INSTALL IT:
SAUMI32W Input/Output Module
- The SAUMI32W Input/Output UPB module is a plug-in device that can
be programmed to control UPB devices and other low voltage devices directly
from its relay outputs. Initial unit address programming is done through
the UPStart software and SAUMCDB9W computer interface module (CIM).
- Connect the CIM to an available PC serial port and open UPStart software.
- From the UPStart Menu, click Device, Add. Choose MFR: Simply Automated,
and Product: UMI-32 3 Input 2 Output Module but do not click Next yet.
- Plug the SAUMI32W into a 110VAC outlet and place in programming mode
by tapping program button 5 times. Program LED’s will start to
blink green. Click Next. Assign SAUMI32W to the first available UPB
unit ID (Default Unit ID is 40).
- Program Link into Input 1 to trigger a UPB switch.
- Identify siren output from alarm panel.
- Using 22AWG 2 conductor wire, connect siren output of alarm panel
to terminals 6 and 7 of the I/O module
SAI Transceiver Switch Installation
- Shut off the circuit breaker that powers the switch that will be replaced.
- Replace the appropriate switch with the SAI Transceiver switch. Refer
to the manufacturer’s instructions for installation details.
- Power up the circuit breaker and test the Transceiver Switch manually
for correct operation.
- Program via UPStart to respond to links programmed in the I/O Module.
See step 4.1.2
- From the UPStart menu, click Device, Add. Choose MFR: Simply Automated
and Product: US1/US2 Dimming Switch. Do not click NEXT yet.
- Place Dimming Switch in Program mode by tapping rocker 5 times. LED
starts to blink green. Click Next.
- Program switch to respond to Links in I/O Module.
SUMMARY
The SAI I/O module is the most important part of the project. With its
multiple inputs, you can also trigger certain lights to blink when the
phone is ringing, when the pool gate is opened, etc. It can also control
sprinkler valves for watering your garden.
Since most alarm panels have a siren output, it is the most accessible
part to interface a UPB lighting system to an alarm panel. The blinking
lights are disabled as soon as the siren output is shut off.
|