TRIPP LITE UPS SYSTEM WITH COAX / PHONE SURGE PROTECTION, 15 VA
LINE-INTERACTIVE UPS SYSTEM WITH ROTATABLE LCD DISPLAY
Tripp Lite's Line-Interactive Digital UPS System offers voltage regulation, surge suppression and long-lasting battery support for home theater/media center components and other sensitive electronic equipment, including PVRs/DVRs, media center PCs/servers, home automation/control systems and security equipment. Internal UPS circuits support entry-level PCs or individual VCR/DVR components during power failures. It prevents data loss, viewing interruptions, lost recordings and loss of component programming. Automatic Voltage Regulation (AVR) circuits regulate brownouts and overvoltages from 75V to 147V back to usable levels without consuming battery power. This UPS System offers complete power protection with support for upright tower, flat shelfmount or 2U rackmount installation in an attractive all-black cabinet design.
UNINTERRUPTIBLE POWER SUPPLIES FROM TRIPP LITE
Tripp Lite UPS backup systems protect equipment from downtime, damage and data loss due to power problems. During a power outage, Tripp Lite backup power supplies allow you to maintain power long enough to save data and shut down PCs, servers and other equipment properly. As an added benefit, Tripp Lite Uninterruptible Power Supplies also protect against power surges and disruptive line noise. Tripp Lite has the perfect UPS System to protect and support every computer and electronics applicationstandby, line-interactive and on-line models in tower, rack mount/tower, low-profile and under-monitor cabinet styles.
Dimable LCD Display indicates input voltage, battery capacity and a variety of operating
conditions. Display is rotatable for easy viewing whether UPS is in vertical or horizontal
position
Offers voltage regulation, surge suppression and long-lasting battery support
during blackouts
Supports entry-level PCs or single VCR/DVR components during blackouts
Regulates brownouts and overvoltages from 75V to 147V back to usable levels without
consuming battery power
8 UPS battery-supported outlets
Included USB port and DB9 serial port enable unattended shutdown in case of
extended power failure
HID-compliant USB interface enables integration with built-in power management and
auto-shutdown features of Windows and Mac OS X.
PowerAlert software available via free download from www.tripplite.com
Set of phone/network jacks protects a single dialup/DSL phone line or network
Ethernet connection
3-line 2.2 GHz coaxial surge protection for cable, satellite and antenna
connections
1500VA/900W power handling ability supports a variety of sensitive computer, home
theater and other equipment
3.5 min. full load runtime (1500VA/900W); 13 min. half-load runtime (750VA/450W)
Cabinet adapts to tower or rackmount shelf format. Rackmount installation brackets
for 2U installation included
Specifications:
Voltage compatibility: 120 VAC
Frequency compatibility: 60
Output:
- Output volt amp capacity (VA): 1500
- Output watt capacity (watts): 900
- Output nominal voltage: 120 VAC
- Output voltage regulation: BATTERY MODE: PWM sine wave 115V +/-5%
- Output frequency regulation: LINE MODE: Passes line frequency of 60Hz +/-10% BATTERY
MODE: Inverter output regulated to 60Hz +/-0.5Hz
- Outlet quantity / type: 8 x NEMA 5-15R
- Overload protection: 10A input circuit breaker
Input:
- Maximum input amps: 8.5
- Input connection type: NEMA 5-15P space saving right angle plug
- Input cord length: 6 ft./1.8m
- Recommended electrical service: 120V 15A
Battery:
- Full load runtime: 3.5 min. (900W)
- Half load runtime: 13 min. (450W)
- Typical battery lifespan: 4-6 years (depending on usage)
- Battery recharge rate: 2-8 hours to 90%
Voltage Regulation:
- Voltage regulation description: Automatic Voltage Regulation (AVR) circuits maintain
clean, regulated computer-grade 120V nominal output, without using battery power, during
brownouts to 75V and overvoltages to 147V
- Overvoltage correction: Input voltages between 128VAC and 147VAC are reduced by 12%
- Brownout correction: Input voltages between 93VAC and 107VAC are boosted by 14%
- Severe brownout correction: Input voltages between 75VAC and 92VAC are boosted by
30%
LEDs Alarms and Switches:
- Front panel LEDs: Front panel LCD screen with blue backlight offers continuous input
line voltage data, plus UPS status information on line power status, battery power status,
battery charge level and voltage regulation operation
- Alarms: Audible alarm with 15-sec. delay sounds to indicate loss of utility power.
Alarm can be silenced by pressing front panel alarm cancel button. Once silenced, alarm
will re-sound when approximately 2 min. runtime remain.
- Switches: Includes 2 front panel switchesone main on/off power switch and one
dual-function alarm cancel/self test button
Surge / Noise Suppression:
- AC surge suppression: 480 joules
- AC suppression response time: Instantaneous
- Dataline suppression: 3-line 2.2 GHz cable/satellite/antenna coaxial surge
protection; single-line tel/DSL or Ethernet surge protection
- EMI / RFI AC noise suppression: Yes
Physical
- Unit Dimensions (HWD/in): Tower format: 17.25 x 3.5 x 10.5 / Rackmount Shelf format:
3.5 x 17.25 x 10.5
- Unit Dimensions (HWD/cm): Tower format: 43.8 x 8.9 x 26.7 / Rackmount Shelf format
8.9 x 43.8 x 26.7
- Material of construction: ABS
- Form factors supported: Rack/Tower
- Cooling method: Convection
Environmental:
- Operating Temperature: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
- Storage Temperature: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
- Relative Humidity: 0 to 95%, non-condensing
Communications:
- Network monitoring port: HID-compliant USB port and DB9 serial port. HID-compliant
USB interface enables integration with built-in power management and auto-shutdown features
of Windows and Mac OS X.
- Software and cabling included: USB cabling included; PowerAlert Software available
for free download at www.tripplite.com
- WatchDog compatibility: Compatible with Tripp Lite's Watchdog system service to
restore operation to locked equipment through soft reboot of application/OS or hard power
off/on reboot of connected equipment; ideal for unattended kiosk applications
Line / Battery Transfer:
- Transfer time from line power to battery mode: 2-4 milliseconds
- Low voltage transfer to battery power: Switches to battery power as line voltage
decreases to 75V or less, switches back to AC mode as line voltage increases to 79V or
higher
- High voltage transfer to battery power: Switches to battery mode as line voltage
increases to 147V or higher, switches back to AC mode as line voltage decreases to 143V or
lower
Certifications:
- Certifications: Tested to UL1778 (USA), CSA C22.2 No. 107.3 (Canada), NOM (Mexico),
Class B (EMI), FCC part 68 and Industry Canada (US & Canada)
Special Features:
- Cold Start: Inverter can be cold started to enable temporary AC output during a
power failure
- Appearance: Attractive black color scheme