FEATURES CORD RETENTION BRACKETS TO KEEP VITAL EQUIPMENT PLUGS CONNECTED
The Tripp Lite Switched, Metered Rack Power Distribution Unit (PDU) enables a variety of advanced network control and monitoring functions by giving IT Managers the ability to turn on, turn off, recycle or lock-out power to each individual receptacle and remotely monitor PDU power consumption and in-rack environmental conditions. A switched PDU system can be accessed, configured and controlled through secure web, SNMP or Telnet Interface. Individually switched outlets can be controlled via a built-in web/network interface, enabling remote reboot of unresponsive network hardware. User defined power-up and power-down outlet sequences ensure proper operation of interdependent IT systems and prevent inrush-related overloads as devices are powered on. Programmable load-shedding of less critical devices at user-defined intervals extends UPS uptime in response to power failures. Unused PDU outlets can be electronically locked off to prevent powering of unauthorized hardware. PDU power consumption (current) is displayed locally and can be monitored via the web/network interface, with user-defined alarms to warn of potential overloads before critical IT mains or branch breakers trip.
Optional ENVIROSENSE temperature/humidity probe enables remote monitoring of in-rack environmental conditions and alarms for up to 3 user supplied contact-closure sensors. It supports real-time monitoring, notification and logging of all on-board reporting functions with user-specified alarm thresholds and actions for each reported condition. Switched PDU systems can be accessed, configured and controlled through secure web, SNMP or Telnet Interface.
Visual and remote current monitoring tracks the output current. Supports 0U vertical rackmount installation with included mounting brackets. Toolless button-mount installation supported in compatible racks. Included cord retention brackets keeps vital network equipment plugged in and continuously powered.
Available In: 15A or 20A. The PDUMV15NET (15A PDU) supports 15A maximum capacity at 120V (agency de-rated to 12 amps). It includes an attached 5-15P input cordset and (16) 5-15R switched outlets. The PDUMV20NET (20A PDU) supports 20A maximum capacity at 120V (agency de-rated to 16A). Includes attached L5-20P input plug and 5-20P adapter set, plus (24) 5-15/20R switched outlets.
TRIPP-LITE POWER DISTRIBUTION UNITS
A Power Distribution Unit (PDU) is a highly reliable, multiple outlet power strip designed to deliver conditioned power to mission-critical networking, server or telecom equipment. It is often used in conjunction with an uninterruptible power supply (UPS).
In a networking environment, devices need to be powered continuously, either from a whole site generator or rack mounted UPS power source, and since many networking devices in use today are fitted with dual redundant power inputs, the total plug count can approach 80 or morewith many requiring two power sources to further mitigate the risk of power failure.
Ideal for network configurations requiring a switched, metered and monitored PDU
supporting individual outlet rebooting, load shedding and remote web/network current monitoring
of critical networking components
15 A PDU Features:
120V 15A maximum capacity (agency de-rated to 12 amps) Switched, Metered and Monitored
Power Distribution Unit (PDU) with built-in web/network interface in 0U vertical rack form factor
Includes attached 5-15P input plug and 16 5-15R controllable outlets
Supports individually controllable output receptacles, current metering, network
monitoring and remote control via built-in web/network monitoring and control card
Offers the ability to turn on, turn off, recycle or lock-out power to each individual PDU
receptacle on a programmable or real-time basis
Switchable outlets enable a number of advanced networking abilities, such as remote
reboot on-demand of locked IT equipment, custom power-on/power-off outlet sequencing, automatic
load-shedding of optional loads during power failures and disabling unused outlets to prevent the
connection of unauthorized equipment loads
Remote interface provides data regarding input power conditions, load level and
individual outlet power status via secure network or web browser interface
Supports notification and logging of all major power events and user specified alarm
thresholds
Optional ENVIROSENSE temperature and humidity probe enables remote monitoring of
environmental conditions and the ability to report conditions from up to two contact-closure
sensors
Optional ENVIROSENSE accessory also supports the connection of up to three user supplied
contact-closure sensors to selectively notify, monitor and log reported conditions, such as rack
door access
DHCP/Manual configuration support provides the ability to have network settings
automatically assigned to the card, or manually assigned via permanent IP addresses
10/100 Mbps auto-sensing allows optimal communication compatibility with your current
10/100 Base-T network
Real-time clock backup maintains the time of day and date even if the PDU is shut down
and unpowered
2-tier level access allows an administrator and a guest to log into the web browser for
monitoring and/or management of all intelligent PDUs and similarly equipped UPS systems
Alert notifications via email or SNMP traps give users the added advantage of having an
immediate event notification
Front panel ammeter displays total PDU power consumption
On initial power-up, outlets are automatically energized at 250 millisecond intervals to
prevent inrush-related equipment interaction and mains circuit overloads
Included cord retention brackets keep vital network equipment plugged in and continuously
powered
49 inch 0U vertical rack installation supported with included mounting brackets
Toolless mounting supported in button-mount compatible racks
Circuit breaker-free format prevents power interruptions due to tripped breakers while
still providing mains panel protection from overloads and short circuit fault conditions
20 A PDU Features:
120V 20A maximum capacity (agency de-rated to 16 amps) Switched, Metered and Monitored Power Distribution Unit (PDU) with built-in web/network interface in 0U vertical rack form factor
Includes attached L5-20P input plug with 5-20P adapter and 24 x 5-15/20R controllable outlets
Supports individually controllable output receptacles, current metering, network monitoring and remote control via built-in Web/network monitoring and control card
Provides the ability to turn on, turn off, recycle or lock out power to each individual PDU receptacle on a programmable or real-time basis
Switchable outlets enable a number of advanced networking abilities, such as remote reboot on-demand of locked IT equipment, custom power-on/power-off outlet sequencing, automatic load-shedding of optional loads during power failures and disabling unused outlets to prevent the connection of unauthorized equipment loads
Remote interface provides data regarding input power conditions, load level and individual outlet power status via secure network or web browser interface
Supports notification and logging of all major power events and user specified alarm thresholds
Optional ENVIROSENSE temperature and humidity probe enables remote monitoring of environmental conditions and the ability to report conditions from up to two contact-closure sensors
Optional ENVIROSENSE probe also supports the connection of up to three user-supplied contact-closure sensors to selectively notify, monitor and log reported conditions, such as rack door access
DHCP/Manual configuration support enables network settings to be automatically assigned to the card, or manually assigned via permanent IP addresses
10/100 Mbps auto-sensing allows optimal communication compatibility with your current 10/100 Base-T network
Real-time clock support maintains the time of day and date even if the PDU is shut down and unpowered
2-tier level access enables an administrator and a guest to log into the web browser for monitoring and/or management of all intelligent PDUs and similarly equipped UPS systems
Alert notifications via email or SNMP traps provide immediate event notification
Front panel ammeter displays whole PDU power consumption in amps
On initial power-up, outlets are automatically energized at 250 millisecond intervals to prevent inrush-related equipment interaction and mains circuit overloads
Included cord retention brackets keep vital network equipment plugged in and continuously powered
Circuit breaker-free format prevents power interruptions due to tripped breakers while still providing mains panel protection from overloads and short circuit fault conditions
63-in. 0U vertical rack installation supported with included rackmount brackets
Toolless mounting supported in button-mount compatible racks
15 PDU Specifications:
SYSTEM OVERVIEW:
Voltage compatibility: 120V
Frequency compatibility: 50/60 Hz
OUTPUT:
Output nominal voltage: 120V
Outlet quantity / type: 16 5-15R
Customized load management receptacles: Each outlet is individually controllable
via remote interface
Overload protection: N.A.
INPUT:
Maximum input amps: 15A maximum (Agency de-rated to 12A continuous)
Input connection type: Attached 5-15P input plugs
Input cord length: 10 ft / 3m
Recommended Electrical Service: 120V
LEDS ALARMS & SWITCHES:
Front panel Leeds: 16-power availability Leeds confirms power off/on status for each built-in
outlet Switches: N.A.
PHYSICAL:
Unit Dimensions (HWD/in): 49 x 2.19 x 4.25
Unit Dimensions (HWD/cm): 124.5 x 5.6 x 10.8
Form factors supported: 0U vertical rack mount. Includes mounting brackets. Supports toolless mounting in button-mount compatible racks
COMMUNICATIONS: SNMP compatibility: Yes, pre-installed SNMPWEBCARD provides
remote monitoring via web, telnet, and SNMP management systems. Remote management gives user
ability to turn connected loads on or off individually
CERTIFICATIONS: Certifications: Tested to 60950-1 (USA, Canada), Class A
(Emissions), NOM (Mexico), RoHS compliant
20 A PDU Specifications:
SYSTEM OVERVIEW:
Voltage compatibility: 120V
Frequency compatibility: 50/60 Hz
OUTPUT:
Output nominal voltage: 120V
Outlet quantity / type: 24 x 5-15/20R
Customized load management receptacles: Each outlet is individually controllable
via remote interface
Overload protection: n/a
INPUT:
20A maximum (agency de-rated to 16A continuous)
Input connection type Attached L5-20P input plug plus 5-20P adapter
Input cord length 10 ft / 3m
Recommended Electrical Service 120V
LEDS ALARMS & SWITCHES:
Front panel LEDs: 24 power availability LEDs confirm power off/on status for each built-in outlet
PHYSICAL:
Unit Dimensions (HWD/in): 63 x 2.19 x 4.25
Unit Dimensions (HWD/cm): 160 x 5.6 x 10.8
Form factors supported: 0U vertical rackmount. Includes mounting brackets.
Supports toolless mounting in button-mount compatible racks
COMMUNICATIONS: SNMP compatibility : Yes, pre-installed SNMPWEBCARD provides
remote monitoring via web, telnet, and SNMP management systems. Remote management gives user
ability to turn connected loads on or off individually
CERTIFICATIONS: Tested to 60950-1 (USA, Canada), Class A
(Emissions), NOM (Mexico), RoHS compliant