ON-LINE, DOUBLE-CONVERSION, PURE SINE WAVE POWER MANAGEMENT SYSTEM
The Tripp Lite Audio/Video Pure Sine Wave UPS System protects connected equipment from blackouts, brownouts, surges and EMI/RFI line noise. It supports enhanced monitoring of UPS and line power conditions via built-in DB9 communication port, included PowerAlert monitoring software and complete cabling. Two controllable load management banks offer remote reboot of selected loads via software interface or automated load shedding to extend battery runtime for the most critical loads during blackouts. It supports 3U rackmount and upright tower form factors and includes mounting hardware for 4-post rack enclosures.
UNINTERRUPTIBLE POWER SUPPLIES FROM TRIPP LITE
Tripp Lite UPS backup systems protect equipment from downtime, damage and data loss due to power problems. During a power outage, Tripp Lite backup power supplies allow you to maintain power long enough to save data and shut down PCs, servers and other equipment properly. As an added benefit, Tripp Lite Uninterruptible Power Supplies also protect against power surges and disruptive line noise. Tripp Lite has the perfect UPS System to protect and support every computer and electronics applicationstandby, line-interactive and on-line models in tower, rack mount/tower, low-profile and under-monitor cabinet styles.
TPHTR223U Pure Sine Wave UPS provides perfectly regulated sine wave output within 2% of 120V under all usage conditions
2200VA/1600W power handling capacity compatible with micro display devices, projectors, PVRs/DVRs, media center PCs, music servers and other sensitive electronics
Removes harmonic distortion, fast electrical impulses, frequency variations and other hard-to-solve power problems not addressed by other UPS types
Corrects line voltage conditions as low as 65V and as high as 138V back to 120V (+/-2%) values
2 switchable load banks (each with 4 outlets) enable remote outlet management for load shedding or remote reboot of individual devices
Standard internal battery set offers 18 min. runtime at half load (800W) and 6 min. at full load (1600W)
Fault-tolerant auto-bypass maintains continuous utility output to connected equipment, even in cases where the UPS suffers internal failure and requires maintenance
Offers complete UPS monitoring through included DB9 interface, or the monitoring of any number of additional UPS systems over IP with included PowerAlert monitoring software
PowerAlert UPS monitoring and unattended shutdown software enables configurable network broadcast messaging, pager and email notification, event logging and running user-defined script commands
Front panel LEDs offer current monitoring and battery charge level information
UPS ships fully assembled in full compliance with DOT regulations; no time-consuming connection of internal batteries by user required
Specifications:
Voltage compatibility: 120 VAC
Frequency compatibility: 50/60 Hz compatible
Output:
- Output volt amp capacity (VA): 2200
- Output watt capacity (watts): 1600
- Output nominal voltage: 120 VAC
- Output voltage regulation: Maintains full-time sine wave output within 2% of selected nominal, less than 3% total harmonic distortion (linear load) / 5% total harmonic distortion (computer load) (Less than 5% THD on-line and on-battery)
- Output frequency regulation: Regulates line frequency to 50/60Hz +/- 0.05Hz
- Outlet quantity / type: 4 x NEMA 5-15R, 4 x NEMA 5-15/20R, 1 x NEMA L5-20R
- Customized load management receptacles: 2 controllable load banks, each with 4 outlets, support automated load shedding and remote reboot on demand of locked network devices
- Overload protection: 2 x 15A output breakers
Input:
- Maximum input amps: 16A
- Input connection type: NEMA 5-20P (NEMA 5-15P included)
- Input cord length: 10 ft.
- Recommended electrical service: 120V 30A dedicated circuit
Battery:
- Full load runtime: 7 min. with internal batteries (1600W)
- Half load runtime: 18 min. with internal batteries (800W)
- Typical battery lifespan: 3-6 years, depending on usage
- Battery recharge rate: Less than 5 hours to 90%
Voltage Regulation:
- Voltage regulation description: On-line, double-conversion power conditioning maintains output within 2% of 100/110/120 volts at all times
- Overvoltage correction: Maintains output of selected nominal +/-2% during overvoltages to 138V AC
- Brownout correction: Maintains output of selected nominal +/-2% during undervoltages to 65V AC (at loads greater than 70% undervoltage correction extends to 80V)
LEDs Alarms and Switches:
- Front panel LEDs: LED STATUS DISPLAY: line power (green), online (green), bypass (yellow), on battery (green), overload (red), battery low (yellow) - 4 LED LOAD / BATTERY LEVEL DISPLAY (100%, 75%, 50%, 25%)
- Alarms: Multi-function audible alarm with distinctive ring patterns offer notification of backup operation (2 sec. on / 0.5 sec. off), low battery warning (1.25 sec. on / 0.5 sec. off), overload (sounds continuously), UPS fault (4.2 sec. on / 1 sec. off), input voltage out of frequency (2.1 sec. on / 0.14 sec. off) and high input voltage (2.1 sec. on 0.07 sec. off)
- Switches: Power off/on switch and battery charge/load level display select switch
Surge / Noise Suppression:
- AC surge suppression: 1014 joules
- AC suppression response time: Instantaneous
- EMI / RFI AC noise suppression: Yes
Physical:
- Unit Dimensions (HWD/in): 5.25 x 17.5 x 20.5
- Unit Dimensions (HWD/cm): 13.3 x 44.5 x 52.1
- Material of construction: Steel
- Form factors supported: Rack/Tower (3U)
- Cooling method: Built-in cooling fan
- Battery Access: Hot-swap battery replacement supported via front access panel
Environmental:
- Operating Temperature: +32 to +104 degrees Fahrenheit; 0 to +40 degrees Celsius
- Storage Temperature: +5 to +122 degrees Fahrenheit; -15 to +50 degrees Celsius
- Relative Humidity: 0 to 95%, non-condensing
Communications:
- Network monitoring port: Built-in DB9 port offers both enhanced RS-232 enabled monitoring data and contact closure monitoring ability
- Software and cabling included: PowerAlert Software CD-ROM
- WatchDog compatibility: Compatible with Tripp Lite's Watchdog system service to restore operation to locked equipment through soft reboot of application / OS or hard power off/on reboot of connected equipmentideal for unattended kiosk applications
Line / Battery Transfer:
- Transfer time from line power to battery mode: Zeroonline UPS continuously converts incoming AC to DC, then back to AC. When commercial power is interrupted, UPS maintains continuous output from battery reserves with absolutely no disruption in output AC power.
- Low voltage transfer to battery power: Maintains continuous operation during undervoltages as low as 65V (80V at load levels over 70%). Below this switchover point, output is supported from battery derived AC power.
- High voltage transfer to battery power: Maintains continuous operation without using battery power during overvoltages to 138V. Above this point, output is supported from battery-derived AC power.
Certifications: Tested to UL1778 (USA), cUL (Canada), NOM (Mexico), FCC Class A (emissions)
Special Features:
- EPO port: Supports Emergency Power Off function via set of dedicated built-in EPO jacks
- Cold Start: Inverter can be cold started to enable temporary AC output during a power failure
- Appearance: Attractive all-black color scheme