Sensaphone IMS-1000 Series Single Room Monitoring Solution
PHIMS100x
Price: $805.50 $895.50
|
|
|
|
|
Product Description
|
SENSAPHONE IMS-1000 SERIES SINGLE ROOM MONITOR
WEB-BASED MONITORING, WITH OR WITHOUT MODEM
IMS1001: Without Modem IMS1002: With Modem
The New IMS-1000 offers web-based monitoring for everyone Sensaphone's latest development, the IMS-1000, provides a flexible, web-based monitoring system for many applications. It connects to any Ethernet network and has a built in web server for viewing status, making programming changes, and reviewing data log history. Up to eight sensors can be connected to monitor a wide variety of conditions including temperature, humidity, physical security, smoke, fire, power, etc. The IMS 1000 is perfect for cold storage applications and even accepts a new -85°C temperatures sensor. It also includes one relay output to switch a local device on or off depending on alarm activity. Power failure monitoring is built-in along with a rechargeable battery backup. Alarm notification is delivered by sending e-mail messages and text messages. An upgrade is available to also include a telephone connection that adds custom voice alarm phone calls. With the phone option users can also call in for a voice status just like most other Sensaphone products. If the IMS-1000 is going to be used in a computer room, additional computer room features are also built-in. IP device monitoring is included to monitor the proper functioning of the servers on your network. Alarms can also be sent via snmp traps, and all programming parameters are accessible through the IMS-1000 snmp agent. - Plug in Sensors
- Web interface
- E-mail messages
- Text messages
- Optional voice phone call alarms
- Built in data logger
- Relay output
- No monthly fees
- No dependencies
- Video camera integration
- IP alarms
- Battery Backup
Easy Set Up: All of the sensors for the IMS-1000 use standard computer patch cables (Cat-5). Just snap in the connector and you're done. The sensors are automatically detected by the 1000 and even self configured. There are no screw terminals to deal with and no wire stripping to worry about. Just plug and go. Easy Programming: A simple fill in the blank web page is provided for all of your detailed programming of the 1000. It only takes a few minutes to type in the monitoring parameters and contact methods. Easy Status View: The single click web summary provides a quick summary of all your monitored conditions. Go to the web page and check the summary as often as you like to verify that everything is okay. Easy History and Trend Information: The IMS-1000 system stores important information for later viewing. This includes the details of alarm events and even periodic snapshots of all of the monitored conditions. This information can be viewed at anytime from the automatically generated web page. You can view single-click quick trends for each monitored condition, or even create a custom history view to see exactly what has been going on at your facility. |
|
Sensaphone IMS-1000 Series Manual (.pdf) Sensaphone IMS-1000 Series Software Release Notes (.pdf)
| | Physical | | Shipping Weight | 8 lbs. | | Dimensions | 14"w x 1.75"h x 7"d | | Telephone Connection (IMS-1002 Only) | FCC approved RJ-11 plug-in modular connector with 6’ cord | | Operating Temperature Range | Unit should be kept between 32° F and 122°F | | Status LEDS | System ON, Battery OK, Output ON, Alarm | | USB Ports | (1) For Future Expansion (not yet available) | | | Mounting | | 1 EIA rack-mount | 1 EIA rack-mount Rack Requirements: Standard 19" equipment rack with supplied mounting bracket hardware. Requires 1.0 EIA rack mount space. | | Tabletop | Tabletop requirements: Flat area which can support an enclosure 14" wide by 7" deep by 2"high. | | | IMS-1000 Operating Specifications | | Temperature | 32–122°F | | Humidity | 5-90% RH non-condensing | | Power Supply | 115VAC 60HZ 9VDC / 1 Amp | | Power Consumption | 10 Watts | | Power Connection | 2.1mm x 10mm jack | | Backup Battery | 6V 3.4AH sealed lead acid | | Backup Time | 3.5 Hours | | Battery Service Life | Under normal operating conditions, three to four years of dependable service life can be expected or between 200 and 1000 charge/discharge cycles, depending on the average depth of discharge. | | | IMS-1000 Communications Specifications: | | Ethernet | 10/100 Base-T, 10/100Mbps | | Protocols | DHCP, TCP/IP, SNMP, HTTP, SMTP, POP, FTP | | Modem (IMS-1002 Only) | Voice / Modem 33.6Kbps, Fax Group 3, 14.4Kbps | | Voice Processor (IMS-1002 Only) | Yes | | Recordable Voice (IMS-1002 Only) | Yes, up to 30 custom messages | | | IMS-1000 Environmental Monitoring | | Internal Monitoring | AC Power (True RMS Voltage), Backup Battery Level | | IP Device Monitoring | up to 16 IP/Port Services | | Number of Sensor Ports | 8 | | Sensor Types | Temperature, Humidity, Water, Power, Current, Infrared Motion, Smoke, Dry Contact, 4-20mA | | Temperature Sensing Range | -109º F to 150º F with remote temperature sensor, NRTL listed for compliance with U.L. Standard 60950-1 | | Sensor Input Connector | RJ-45 | | Sensor Cables | CAT-5, 568B | | Cable Length | 1000’ | | Visual Indicators | LEDs, Normal and Alarm | | | Output Relays | | Number Of Outputs | 1 | | Output Type | SPDT (Form C) Latching, 1A 30VAC or 1A 24VDC | | Output mode | Manual, Automatic on alarm | | Warranty | 3-year Limited Warranty | |
|
Product Accessories
|
|
|
|
|
|
|
|
|
|
|