Leviton SmartlockPro GFCI Duplex Receptacle, 15A
LV7599x

Price: $17.95

  
Quantity
 
Satisfaction Guaranteed No Hassle Returns
Free Tech Support Industry Experts
Get free shipping for retail orders of 200.00 or more.  Some exclusions apply.

arrow Product Description
LEVITON 15A SMARTLOCK PRO GFCI RECEPTACLE

WALLPLATE AND SCREWS INCLUDED

  • 15 Amp-125 Volt @ Receptacle, 20 Amp-125 Volt Feed-Through.
  • SmartLock Pro GFCI Monochromatic Receptacle, phase 7 design nema 5-15R.
  • Nylon wallplate and screws included, back and side wired, less grounding clip.

Automatically test the GFCI every time the RESET button is pushed in. The GFCI will not reset if the GFCI circuit in not functioning properly. By blocking reset of the GFCI if protection has been compromised, SmartLockPRO reduces the possibility of end-users incorrectly assuming that a reset GFCI outlet is providing ground fault protection when it actually is not. A line-load reversal diagnostic feature is provided which prevents the GFCI from being reset and stops power from being fed to the GFCI receptacle face or through to downstream devices. A green LED indicator on the GFCI's face also illuminates to alert the installer to the line-load wiring reversal.

  • Automatically test the GFCI every time the RESET button is pushed in. The GFCI will not reset if the GFCI circuit is not functioning properly.
  • By blocking reset of the GFCI if protection has been compromised, SmartLockPRO reduces the possibility of end-users incorrectly assuming that a reset GFCI outlet is providing ground fault protection when it actually is not.
  • A line-load reversal diagnostic feature is provided which prevents the GFCI from being reset and stops power from being fed to the GFCI receptacle face or through to downstream devices. A green LED indicator on the GFCI’s face also illuminates to alert the installer to the line-load wiring reversal.
  • The trip latch mechanism in SmartLockPro GFCIs is a one piece "T" design for efficient operation
  • There are 4 sets of contacts for load terminals and face. SmartLockPRO GFCIs use a patented bifurcated bridge contact for efficient operation
  • Trip threshold meets or exceeds UL requirements for tripping time
  • Improved immunity to high-frequency noise reduces nuisance tripping
  • Advanced electronics design provides superior resistance to electrical surges and over-voltages
  • Expanded wiring options with nine back-wire holes two for each line and load connection plus one for ground with an internal clamp)
  • Silver alloy contacts
  • Compatible with all Decora devices and wallplates; available in select Decora colors

LEVITON SMARTLOCK PRO

Leviton's SmartLockPRO GFCI raises the bar for electrical safety and complies with UL's latest GFCI requirements which go into effect today. Based on the patented lock-out feature of Leviton's original SmartLock GFCI, the SmartLockPRO offers two-stage protection against ground fault shock hazard, adding enhanced electrical safety features.

As part of its two-stage protection feature, the SmartLockPRO cannot be reset when its line and load terminals are mis-wired. In instances of an improperly wired line-load reversal, the green diagnostic LED indicator will turn ON to signal the wiring error. Once the device is properly re-wired it can be reset and its LED will function as a power indicator light, signaling that power is available at the receptacle.

A second stage of protection is afforded during the GFCI's service life. If the device fails to work properly (i.e., stops providing ground fault protection) at any time after it is installed, it cannot be reset. This provides a clear indication to users that the device must be replaced.

Electrical Specifications

  • Dielectric Voltage: Withstands 1500V per UL498
  • Current Limiting: 10kA
  • Temperature Rise: Max 30C after 50 cycles OL at 150 percent rated current

Environmental Specifications

  • Flammability: Rated V-2 per UL94
  • Operating Temperature: -35C to 65C

Material Specifications

  • Face Material: Thermoplastic Nylon
  • Body Material: Thermoplastic Nylon
  • Line Contacts: Brass Triple-Wipe .031 Thick
  • Terminal Screws: Brass 10-32
  • Grounding Screw: Brass 8-32
  • Yoke: Zinc-Plated Steel
  • Clamp Nuts: Zinc-Plated Steel

Mechanical Specifications

  • Terminal ID: Brass-Hot, Green-Ground, White-Neutral
  • Terminal Accom.: 14-12 AWG
  • Product ID: Ratings are permanently marked on device

Standards and Certifications

  • NEMA: WD-6
  • ANSI: C-73
  • UL498: File E13399
  • CSA C22.2 No. 42: File LR-57811
  • NOM: 057