Couples X10 signals across 2 & 3 phase systems. This Noise Block keeps extraneous noise and...
Price: $29.95
Product Description
BLOW OUT SALE!
Priced BELOW our cost! VERY limited quantities! Don't miss this deal!
LEVITON WHOLE-HOME NOISE BLOCK
KEEP UNWANTED X10 SIGNALS OUT OF YOUR HOME!
Couples X10 signals across single AND 3-phase systems. This Whole-Home Noise Block shields extraneous noise and X10 signals which could interfere with the normal operation of your household X10 devices. A must for increasing the reliability of X10 performance within your home!
Compatible with single phase 120/240 VAC, three phase 120/277 VAC
11/16" diameter cylindrical opening through body of the coupler
Installation Instructions:
Turn off power at the breaker/panel and test that power is off before wiring.
Pass the service's neutral cable through the hole in the body of the blocking coupler, making sure that the arrow on the label points towards the circuit breaker/fuse box. The blocking coupler installs between the circuit breaker panel and the meter socket base or incoming power.
Remove 3/4" of insulation from the ends of the circuit conductors (12 AWG) to be used to connect the blocking coupler to the breaker panel. Conductors are user-supplied.
Connect the conductors to the blocking coupler, and tighten them under the terminal screws. The neutral (N) screw on the blocking coupler should be connected to a suitable connection point in the circuit breaker/fuse box. Each of the phase terminals (L1, L2, and L3) are connected to dedicated circuit breakers which are connected to the respective phases in the circuit breaker/fuse box. For single phase applications, use the L1 and L2 terminals.
Making sure the conductors are securely placed between the terminal clamps, tighten the terminal screws tightly.
Secure the blocking coupler to the panel enclosure.