HAI OMNI IIe INTELLIGENT CONTROLLER
HAI has redesigned the Omni II! The Omni IIe includes an ethernet port, 5 active serial ports, and expanded voice description codes!
VERSITILITY AND AFFORDABILITY FROM HAI OMNI IIe
The Omni IIe is an automation controller with integrated security for homes and small businesses. The system provides enhanced comfort, safety, convenience and energy savings by coordinating lighting, heating and air, security, scenes and messaging based on lifestyles and schedules. At the heart of the Omni IIe is HAI's Advanced Control Programming (ACP) which allows installers and owners to set schedules and actions performed by the system.
Omni IIe comes with several standard modes, such as Day, Night, Away and Vacation, and can accept customized scenes such as "Good night", "Good morning" or "Entertainment" that set temperatures, lights and security to the desired levels with one touch. Security and temperature sensors can be used to adjust lights, appliances and thermostats, monitor activity and track events. The home can be controlled and programmed by the dealer or the homeowner, on-site or from a remote location. Easy to read LCD consoles show status and allow control and scheduling of lighting, security, temperatures and accessories.
Omni IIe has a built-in serial interface for connection to the Internet via HAI Web-Link II, personal computers and options like touchscreens, voice recognition and home theater controls. Omni IIe features telephone accessibility from within the home or a remote location with clear voice menus for convenience and simplicity. The built-in digital communicator reports alarm events to a central station and can dial up to 8 additional phone numbers chosen by the home owner for voice notification.
NOTE: Currently, HCI is not offering additional languages, but we can take a special order.
"HAI AUTOMATION WITHIN"
An ideal and economical choice for homes and small businesses, Omni IIe is the middle member of HAI's best-selling Omni product line. It supports numerous Omni family accessories, including a complete line of fully communicating thermostats. Omni IIe is the 5th generation controller from HAI - the company that's been leading the industry since 1985.
Enclosure Dimensions: 13.5"W x 13.5"H x 5"D
Controls up to 72 different lights, appliances or groups: 64 via power line carrier control modules or optional ALC hardwire lighting modules, 8 hardwired to Omni IIe controller
Temperature control for 4 HAI Omnistat thermostats
Omni IIe sends time, outdoor temperature to thermostats for display
Time, Sunrise, Sunset, outdoor temperature display
Temperature control for other items or existing thermostats using up to 8 Temperature Sensors or PESMs
2-Way X-10 and ALC allows Omni IIe to receive signals for use as program triggers, features collision detection and retry for reliability
Lights can be set to scenes of varying brightness, with Level, Ramp and Scene Support for architectural quality lighting control
Lights, control outputs, temperatures and security modes can be scheduled by time, sunrise, sunset, and date or day of week and various system events.
500 lines of non volatile ACP program storage
Commands (immediate and scheduled) include: on, off, dim, brighten, level, (and ramp rate for ALC)
timed on, off, dim, bright change settings, mode, fan for one or all thermostats,
change system modes, zone status, flags, say, display or place a call with a message
activate a button (macro), scene select
Supports HAI Pro-Link, which allows two-way serial communications with other controllers using ASCII messages
Event button capability ("Scenes" or "macros") allows a series of commands to be executed at once, to create lighting scenes, house modes, adjust temperatures, etc., initiated by: a console, computer or telephone command,
a zone opened or closed,
a mode change (i.e. day, away, vacation),
a particular user code entered
a time schedule, sunrise, sunset
other internal or external events
Enhanced ACP includes new commands for "real time pricing" of energy costs, and allows two conditionals per line for easier programming
Automatic Daylight Saving Time adjustment
Expansion port for future SCP, UPnP, LonWorks or other interface
SECURITY FEATURES:
16 Zones, expandable to 48 zones
supports two 10A06 16 zone hardwire expanders
full selection of security zone types, keyswitch,
outdoor temperature, energy saver module
temperature control and/or alarm
auxiliary input for automation use (without security)
all zones support 4 wire smoke detectors
zone 1-4 support 2 wire smoke detectors
8 Hardwire Outputs, fully configurable for: control output for automation
temperature control,
long range radio
armed, OK to arm, and others
LCD Consoles: surface, flush and universal models available
4 wire connection, independent operation, 8 maximum
configurable beeper, viewing angle, backlighting
Features:
True Partitions: security and automation can be partitioned into 2 areas
Five modes: off, day, night, away, vacation
16 user codes with selectable authority levels
User codes can be made valid during certain times and days only, for maid, service, etc.
All lights on when alarm is tripped to frighten intruder away
Outdoor lights flashing when alarm is tripped to alert neighbors and police
Entry, Exit, outdoor sirens delays user programmable
Entry delay can be doubled or quadrupled on a zone to accommodate garage and back doors
Pre-alarm beeper in console and separate indoor siren output gives owner time to turn alarm off before outdoor siren is activated
Two separate, supervised outputs for indoor and outdoor sirens
System Announces type and location of alarm with optional 2-Way Voice Module
Auto bypass feature means alarm won't go off unexpectedly if door or window is left open when the system is armed
Trouble conditions indicated in English on display
Phone line monitor
High Security mode for commercial applications
All Fire and Burglary zones are fully supervised
Event Log with Time & Date
TELEPHONE CONTROL FEATURES:
Works with Touch Tone phones inside or away from the premises with access code
Compatible with answering machines, answering services
Lockout feature discourages tampering with system by phone
Listen-in / talk to premises with optional two way voice module
From any phone, you can: change modes, temperatures, macros
arm/disarm security, bypass and restore zones,
hear complete status of system
hear event log and help menu
DIGITAL DIALER FEATURES:
Contact ID, 4/2 and 3/1 formats, dual round compared
Two phone numbers with two account numbers
Opening/Closing reports by user code
VOICE DIALER FEATURES:
Completely solid state, no tape or moving parts to wear or break
Voice dialer is delayed by 5 minutes if digital dialer is used to allow central station to call back
Dials up to 8 user programmable numbers and reports type and location of alarm
Called party can cancel dial out by entering code
Omni IIe can call pagers, and be programmed to make a voice call based on a non-alarm event (example: call when children arrive home; call if "no activity" for elderly care)
RELIABILITY FEATURES:
Designed for continuous trouble-free operation
Verifies smoke detectors by cycling power and confirming smoke alarm
System reads resistance of each zone independently to detect trouble due to faulty sensor or wiring before it causes false alarms
Fuse-less, short-proof design
Programmable delay to preclude false alarms from user error
All inputs and outputs protected against static, RFI, surges, and lightning by use of impedance limits, spark gaps, TRANZORB surge arrestors, RC filters, MOVs, bypass capacitors and grounded shields
Watchdog timer, non volatile EEPROM storage for ALL programs, self diagnostic software, low voltage cut out, self protecting power supply for system integrity
EASE OF USE FEATURES:
Text descriptions for all zones, units, codes, and macros
Voice descriptions on telephone
Console display shows menus to guide users during use
Minimum keystrokes for common functions
Quick mode change feature
Optional wireless keyfob for arming and control available
Web Browser Graphical Display (HAI Web-Link II) available
TECHNICAL:
Power supply: Requires 24 VAC transformer, 50/60 Hz
Built in Omni-Link or Pro-Link serial interface, with jumper for RS-232 or RS-485. Can be used for programming, connection to HAI Web-Link II, personal computers and Connectivity Partner options
Built-in v.22 bis fast modem for local or remote (with security code) access to system using personal computer
Everything in Omni IIe can be programmed using HAI PC Access software for personal computer
OPTIONS:
HAI Web-Link II Internet and Local Area Network software (Windows)
HAI PC Access configuration, monitoring and programming software (Windows)
2-way voice module
Additional Serial Board
16 Zone hardwire expansion card
ALC Hardwire Lighting Control Module
APPROVALS:
UL Residential Fire and Burglary
UL Commercial Burglary
FCC (USA)
ICCS-03 (Canada)
California State Fire Marshall
CE (Europe): Electromagnetic Compatibility, Emissions and Immunity