NAPCO's Gemini™ GEM-P3200 a popular, all-around 8 zone hybrid control expandable to 32 zones or 48 wireless points.
Napco's Gemini GEM-P3200 is a state-of-the-art microcomputer-based burglary and residential fire alarm control panel of modular design. Integrally an 8-zone panel, it will support up to 32 zones with optional zone expansion modules, wireless receiver modules and/or GEM-RP1CA/RP1CAe/RP1CAe2 Keypads. Each panel includes an integral digital communicator. The control panel features programmable area partitioning. That is, the system may be divided into up to two discrete multiple-zone areas, each allowing access by only those users programmed for their respective area.
Opening Suppression and Closing Suppression, available through Napco Quickloader software, suppress reporting within programmed ôwindows". Conversely, Exception Reporting can transmit a ôfail to close" if the panel is not armed within programmed intervals and, similarly, a ôfail to open" if the panel is not disarmed within programmed intervals. Furthermore, the panel can be programmed to automatically arm either area at any time. A log containing up to 800 events (accessible through QuickloaderTM software) monitors control-panel activity referenced to a precision real-time clock. A detailed event history may be displayed at the computer, using Napco's PCD3000 Quickloader Software.
Keypads feature a liquid-crystal display for messages. In normal use, the LCD shows zone identification and status messages. Conventional LEDs and a sounder are also provided for annunciation.
Data may be quickly and easily downloaded to the control panel using a PC-compatible computer with Napco's PCD3000 Quickloader software and PCI2000 computer interface. Or, the panel may be programmed using the keypad in its secondary mode of operation. In the keypad programming modes (there are two: Dealer and User), the LCD shows memory address, data values, programming prompts, and the alphanumeric characters required for entering up to 32 user codes and custom zone descriptions.
THE NAPCO GEMINI SECURITY LINE
Now you can have the reliability and quality NAPCO products are known for in a new, comprehensive line of hybrid hardwire/wireless multi-tasking products, including 8 to 96 zone controls, smart keypads, RF receivers and transmitters. Combines exceptionally precise crystal control, helically-filtered receivers, omni-directional transmitter patterns and the very same Glide Slope transmission technology used by the U.S. military. Not only will you love the looks and intuitive operation of the Gemini keypad styles, but you will find their exclusive metering and display of actual transmitter strength invaluable.
Expandable using up to 6, 4-Zone GEM-EZM4s or 3, 8-Zone GEM-EZM8s
Up to 32 Fire Zones, including two 2-Wire Fire Zones
Up/downloading, including unique Unattended Method
Fully Self-Programming
Up to 2 Areas
Up to 32 User Codes
3 On-Board Relay Outputs
1 On-Board Programmable Lug
Up to 24 Relays
Supports 2 Wireless Receivers
Supports 7 Keypads - One Interior Bypass Groups
X-10 Support, for 24 devices (with GEM-X10)
800 Event Log w/ Open/Close Suppress
Auto Arm/Disarm
255 Event Scheduler
All Major Communication Formats & Secondary Pager Format
Telco Line Cut Supervision
Output Power Amps (w/ 40VA Transformer, included) 0.65/40VA
SPECIFICATIONS:
Panel Dimensions: Box size is 12.375" long x 13.875" wide x 3.55" high
Operating Temperature: 0-49°C (32-120°F)
Input Power: 16.5VAC via CLASS 2 Plug-In 40VA or 50VA Transformer
Loop Voltage: 10-13Vdc
Loop Current: 2.4mA with 2.2K Ohm end-of-line resistor (Model EOL2.2K); 5mA for 2-wire smoke-detector zones; 1.4 mA
using a 3.9K Ohm resistor (Model EOL 3.9K) with Zone Doubling
Loop Resistance: 300W max.; 50W for 2-wire smoke-detector zones
Relay Outputs (Burglary; Reset; Aux): Wet, 12Vdc, 1.2A max.; Dry (cut related jumper for dry contacts; see Wiring
Diagram), SPDT contacts 24Vdc, 2A, 0.6 PF
Auxiliary Power Output: 12Vdc regulated
Remote Power Output: 12Vdc regulated (for keypads)